Postgraduate DiplomaHealth, Biomechanics, Wearables & Operational Safety Applications open

Postgraduate Diploma in IEC 60601 Conformity (Safety/EMC)

Online 800-hour Postgraduate Diploma in IEC 60601 conformity (Safety/EMC). 8 modules covering IEC 60601-1 (basic safety and essential performance), IEC 60601-1-2 (electromagnetic compatibility) and Fluke Ansur. Dedicated tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Interpret the structure of the IEC 60601 family and its collateral standards.

02

Design means of protecting the patient and the operator against electrical hazards.

03

Assess mechanical, thermal and fire risks in electromedical equipment.

04

Plan electromagnetic compatibility tests in accordance with IEC 60601-1-2.

05

Apply the requirements for software and medical electrical systems.

06

Link conformity with risk management in accordance with ISO 14971.

07

Draft the conformity plan for an electromedical device.

Profile

Who it's for

  • Regulatory compliance engineer who wants to specialise in IEC 60601 Conformity (Safety/EMC).
  • Medical electrical safety engineer who wants to specialise in IEC 60601 Conformity (Safety/EMC).
  • EMC engineer who wants to specialise in IEC 60601 Conformity (Safety/EMC).
  • Electromedical equipment design engineer who wants to specialise in IEC 60601 Conformity (Safety/EMC).
  • Certification laboratory technician who wants to specialise in IEC 60601 Conformity (Safety/EMC).
  • Regulatory affairs specialist who wants to specialise in IEC 60601 Conformity (Safety/EMC).
  • Engineering or science graduates looking to enter healthcare technology.
Standards & tools

What you'll work with

  • IEC 60601-1 (basic safety and essential performance)
  • IEC 60601-1-2 (electromagnetic compatibility)
  • ISO 14971 (risk management for medical devices)
  • IEC 62304 (medical device software)
  • IEC 60601-1-6 (usability)
  • IEC 60601-1-8 (alarm systems)
  • IEC 60601-1-11 (home healthcare environment)
Syllabus

8 modules · 800 h

  1. 1.1General, collateral and particular standards
  2. 1.2Edition 3.2 and amendments
  3. 1.3Essential performance and basic safety
  4. 1.4Risk management according to ISO 14971
  5. 1.5Equipment classification and applied parts
  6. 1.6Accompanying documents and marking
  7. 1.7Relationship with the MDR and harmonised standards
  8. 1.8CB scheme and TRF reports
  9. 1.9Planning the certification project
  10. 1.10Practical: identifying the essential performance of a ventilator
  1. 2.1Means of operator and patient protection
  2. 2.2Basic, double and reinforced insulation
  3. 2.3Insulation distances and creepage paths
  4. 2.4Working voltages and categories
  5. 2.5Leakage currents and limits
  6. 2.6Dielectric tests
  7. 2.7Protection against defibrillation
  8. 2.8Mains connection and power supplies
  9. 2.9Protective earthing
  10. 2.10Laboratory: insulation diagram of a device
  1. 3.1Stability and moving parts
  2. 3.2Mechanical strength and drops
  3. 3.3Temperatures of accessible parts
  4. 3.4Fire protection
  5. 3.5Materials and enclosures
  6. 3.6Liquid spillage
  7. 3.7IPX water ingress
  8. 3.8High-integrity components
  9. 3.9Single fault conditions
  10. 3.10Practical: analysis of single fault conditions
  1. 4.1Edition 4.1 and use environments
  2. 4.2Conducted and radiated emissions CISPR 11
  3. 4.3Immunity to electrostatic discharges
  4. 4.4Radiated immunity and proximity fields
  5. 4.5Fast transients and surges
  6. 4.6Voltage dips and interruptions
  7. 4.7Mains-frequency magnetic fields
  8. 4.8Acceptance criteria and essential performance
  9. 4.9EMC test plan
  10. 4.10Workshop: drafting an EMC test plan
  1. 5.1IEC 60601-1-6 on usability
  2. 5.2IEC 60601-1-8 on alarms
  3. 5.3IEC 60601-1-11 for home use
  4. 5.4IEC 60601-1-12 for emergency services
  5. 5.5IEC 60601-1-10 on physiological controllers
  6. 5.6Radiation requirements IEC 60601-1-3
  7. 5.7Selection of applicable collateral standards
  8. 5.8Interaction with particular standards
  9. 5.9Examples of common non-conformities
  10. 5.10Case study: applicability of collateral standards to a home monitor
  1. 6.1Clause 14 on PEMS systems
  2. 6.2IEC 62304 lifecycle
  3. 6.3Cybersecurity IEC 81001-5-1
  4. 6.4ME systems under clause 16
  5. 6.5Non-medical equipment in the patient environment
  6. 6.6IT networks IEC 80001-1
  7. 6.7Updates and change management
  8. 6.8Software validation
  9. 6.9Software documentation
  10. 6.10Practical: software safety classification
  1. 7.1Insulation architecture in the design
  2. 7.2Selection of medical power supplies
  3. 7.3PCB design for EMC
  4. 7.4Filtering and shielding
  5. 7.5Pre-testing in your own laboratory
  6. 7.6Diagnosis of EMC failures
  7. 7.7Component supplier management
  8. 7.8Standards-oriented design reviews
  9. 7.9Maintaining conformity during changes
  10. 7.10Case study: correcting a radiated emissions failure
  1. 8.1Description of the equipment and intended use
  2. 8.2Risk analysis
  3. 8.3Insulation diagram
  4. 8.4Safety test plan
  5. 8.5EMC test plan
  6. 8.6Collateral standards matrix
  7. 8.7Conformity dossier
  8. 8.8Action plan
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

100 % online training on the SEIUM campus, with downloadable material, recorded classes and a dedicated technical tutor. No fixed timetables: students progress at their own pace within the intake, which makes it easy to combine with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Fluke Ansur, LTspice, Ansys Icepak, MATLAB, advanced Excel (traceability matrix), in free, academic or evaluation versions. Tests are studied using real procedures for leakage current and dielectric strength tests, an EMC semi-anechoic chamber and document review of the risk management file. Assessment is continuous per module, plus the final integrating project.

Accreditation-ready laboratories(EN ISO/IEC 17025) with a rotor test bench, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-driven final project:safety case, test plan, compliance dossier and operating limits.
Industry mentoring:lecturers with experience in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:safety-by-design approach, with ciber-OT, DIH and compliance as core pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Description of the equipment and intended use

Interpret the structure of the IEC 60601 family and its collateral standards.

Risk analysis

Design means of protecting the patient and the operator against electrical hazards.

Insulation diagram

Assess mechanical, thermal and fire risks in electromedical equipment.

Safety test plan

Plan electromagnetic compatibility tests in accordance with IEC 60601-1-2.

EMC test plan

Apply the requirements for software and medical electrical systems.

Career opportunities

Where this takes you

Regulatory compliance engineerMedical electrical safety engineerEMC engineerElectromedical equipment design engineerCertification laboratory technicianRegulatory affairs specialist
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient level of Spanish to follow technical standards documentation.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours, spread over 6 to 8 months. That is between 10 and 15 hours per week on average, compatible with full-time work.

You will work with Fluke Ansur, LTspice, Ansys Icepak, MATLAB, advanced Excel (traceability matrix). Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM diploma upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are credited towards the advanced programme. Check the credit recognition policy when you enrol.

Postgraduate Diploma in IEC 60601 Conformity (Safety/EMC)Enrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.