Postgraduate DiplomaHealth, Biomechanics, Wearables & Operational Safety Applications open

Postgraduate Diploma in Noise, Vibration and Lighting Assessment

800-hour online Postgraduate Diploma in Noise, Vibration and Lighting Assessment. 8 modules covering Real Decreto 286/2006 (exposure to noise), UNE-EN ISO 9612 (determination of noise exposure) and DIALux evo. Assigned tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Identify the physical agents present in the workplace.

02

Measure noise exposure using the strategy of UNE-EN ISO 9612.

03

Propose technical measures to control noise.

04

Assess exposure to vibration in accordance with current regulations.

05

Measure photometric parameters with a lux meter.

06

Design lighting systems in accordance with UNE-EN 12464-1.

07

Prepare an integrated report on the assessment of physical agents.

Profile

Who it's for

  • Industrial hygiene technician wishing to specialise in Noise, Vibration and Lighting Assessment.
  • Senior prevention technician wishing to specialise in Noise, Vibration and Lighting Assessment.
  • Acoustic consultant wishing to specialise in Noise, Vibration and Lighting Assessment.
  • Lighting designer wishing to specialise in Noise, Vibration and Lighting Assessment.
  • Environmental measurement technician wishing to specialise in Noise, Vibration and Lighting Assessment.
  • Noise control engineer wishing to specialise in Noise, Vibration and Lighting Assessment.
  • Engineering or science graduates seeking to enter the manufacturing industry.
Standards & tools

What you'll work with

  • Real Decreto 286/2006 (exposure to noise)
  • UNE-EN ISO 9612 (determination of noise exposure)
  • UNE-EN 12464-1 (lighting of indoor workplaces)
  • Real Decreto 1311/2005 (exposure to vibration)
  • Real Decreto 486/1997 (workplaces)
  • IEC 61672-1 (sound level meters)
  • ISO 5349-1
Syllabus

8 modules · 800 h

  1. 1.1Physical agents: noise, vibration and lighting
  2. 1.2Law 31/1995 and risk assessment
  3. 1.3Real Decreto 286/2006 on noise
  4. 1.4Real Decreto 1311/2005 on vibration
  5. 1.5Real Decreto 486/1997 on workplaces
  6. 1.6INSST technical guides
  7. 1.7Effects on health and performance
  8. 1.8Specific health surveillance
  9. 1.9Assessment strategy and sampling
  10. 1.10Case study: planning the assessment of an industrial plant
  1. 2.1Acoustic quantities: pressure, power and decibels
  2. 2.2A and C weightings
  3. 2.3Equivalent level and peak level
  4. 2.4Sound level meters and dosimeters: IEC 61672
  5. 2.5UNE-EN ISO 9612 standard
  6. 2.6Strategies by task, function and shift
  7. 2.7Measurement uncertainty
  8. 2.8Octave band analysis
  9. 2.9Calibration and verification of equipment
  10. 2.10Laboratory: daily exposure measurement with a dosimeter
  1. 3.1Hierarchy of control measures
  2. 3.2Reduction at source
  3. 3.3Enclosures and encapsulation
  4. 3.4Acoustic screens and absorption
  5. 3.5Acoustic treatment of rooms
  6. 3.6Silencers and control of structural vibration
  7. 3.7Hearing conservation programmes
  8. 3.8Selection of hearing protectors: SNR and HML method
  9. 3.9Audiometry and noise-induced hearing loss
  10. 3.10Practice: designing an enclosure for a press
  1. 4.1Hand-arm and whole-body vibration
  2. 4.2Frequency-weighted acceleration and A(8) value
  3. 4.3Action and limit values
  4. 4.4Accelerometers and mounting
  5. 4.5Estimation using manufacturers' data
  6. 4.6Highest-risk tools and vehicles
  7. 4.7Technical and organisational control measures
  8. 4.8Hand-arm vibration syndrome
  9. 4.9Vibration-induced lumbar disorders
  10. 4.10Laboratory: vibration measurement on a portable tool
  1. 5.1Photometric quantities: luminous flux, illuminance and luminance
  2. 5.2Requirements of UNE-EN 12464-1
  3. 5.3Uniformity and glare (UGR)
  4. 5.4Colour rendering and colour temperature
  5. 5.5Lux meters and luminance meters
  6. 5.6Measurement grid and procedure
  7. 5.7Lighting and display screens
  8. 5.8Daylight and its use
  9. 5.9Non-visual effects of light
  10. 5.10Practice: measuring illuminance in an office
  1. 6.1Types of luminaire and photometric distribution
  2. 6.2LED technology and drivers
  3. 6.3Lumen method calculation
  4. 6.4Simulation with DIALux
  5. 6.5Emergency lighting
  6. 6.6Control and dimming: sensors and DALI
  7. 6.7Energy efficiency of the installation
  8. 6.8Maintenance and maintenance factor
  9. 6.9Lighting of outdoor work areas
  10. 6.10Workshop: DIALux project for a warehouse
  1. 7.1Interaction between noise, vibration and lighting
  2. 7.2Environmental comfort and productivity
  3. 7.3Assessment of multi-risk workstations
  4. 7.4Industrial hygiene technical reports
  5. 7.5Prioritisation of corrective measures
  6. 7.6Cost-benefit analysis of measures
  7. 7.7Communicating results to workers
  8. 7.8Reassessment and monitoring
  9. 7.9Audit of physical agent management
  10. 7.10Case study: assessment of a boilermaking workshop
  1. 8.1Selection of the workplace
  2. 8.2Sampling plan
  3. 8.3Noise measurement
  4. 8.4Vibration measurement
  5. 8.5Lighting measurement
  6. 8.6Analysis of results against limits
  7. 8.7Proposal of corrective measures
  8. 8.8Technical report
  9. 8.9Written report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

Training is 100 % online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the intake, which allows them to combine it with work.

Each module combines theory, guided reading of the original standard and applied exercises. The software used is DIALux evo, CadnaA, Advanced Excel, MATLAB, in free, academic or evaluation versions. Tests are studied using real procedures for sound level measurement in the workplace, illuminance measurement with a lux meter and vibration measurement with an accelerometer. Assessment is continuous by module, plus the final integrating project.

Accreditation-ready laboratories(EN ISO/IEC 17025) with a rotor test rig, EMC/Lightning pre-compliance, HIL/SIL and vibration/acoustics.
Evidence-driven Master's Thesis:safety case, test plan, compliance dossier and operational limits.
Industry mentoring:teaching staff with experience in training, , eVTOL/UAM and flight test.
Flexible format:(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:safety-by-design approach, OT cyber, DIH and compliance as pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Selection of the workplace

Identify the physical agents present in the workplace.

Sampling plan

Measure noise exposure using the strategy of UNE-EN ISO 9612.

Noise measurement

Propose technical measures to control noise.

Vibration measurement

Assess exposure to vibration in accordance with current regulations.

Lighting measurement

Measure photometric parameters with a lux meter.

Career opportunities

Where this takes you

Industrial hygiene technicianSenior prevention technicianAcoustic consultantLighting designerEnvironmental measurement technicianNoise control engineer
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. A university degree is not required.
  • Internet connection and a computer capable of running the programme's software.
  • A sufficient level of Spanish to follow technical regulations.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours, spread over 6 to 8 months. That is an average of 10 to 15 hours per week, compatible with full-time work.

The programme uses DIALux evo, CadnaA, Advanced Excel and MATLAB. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM diploma upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area can be credited towards the advanced programme. Check the recognition policy when you enrol.

Postgraduate Diploma in Noise, Vibration and Lighting AssessmentEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.