Course in Protection Coordination in MV/LV Networks
Online 300-hour course in protection coordination in MV/LV networks. 6 modules covering IEC 60909 (short-circuit currents in three-phase systems), IEC 60255-151 (overcurrent protection requirements) and ETAP. Assigned tutor and open enrolment.
Take the controls.
Run a real engineering trade-off from this programme. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Collect and model the data required for a coordination study.
Calculate maximum and minimum short-circuit currents according to IEC 60909.
Interpret and plot time-current curves for relays, fuses and circuit breakers.
Coordinate medium-voltage protection with adequate margins.
Ensure full or partial selectivity in low-voltage installations.
Verify existing settings and diagnose spurious trips.
Write a complete MV/LV protection coordination study.
Who it's for
- Electrical studies engineer wishing to specialise in Protection Coordination in MV/LV Networks.
- Designer of medium- and low-voltage installations wishing to specialise in Protection Coordination in MV/LV Networks.
- Protection technician wishing to specialise in Protection Coordination in MV/LV Networks.
- Electrical maintenance manager wishing to specialise in Protection Coordination in MV/LV Networks.
- Distribution engineer wishing to specialise in Protection Coordination in MV/LV Networks.
- Electrical safety consultant wishing to specialise in Protection Coordination in MV/LV Networks.
- Engineering or science graduates looking to enter industry.
What you'll work with
- IEC 60909 (short-circuit currents in three-phase systems)
- IEC 60255-151 (overcurrent protection requirements)
- IEEE 242 (protection and coordination in industrial systems)
- IEC 60282-1 (high-voltage fuses)
- IEC 60269 (low-voltage fuses)
- IEC 60947-2 (circuit breakers)
- Real Decreto 842/2002 (Low-Voltage Electrotechnical Regulation)
6 modules · 300 h
1.1Equipment data collection1.2Single-line diagrams of the installation1.3Short circuits according to IEC 609091.4Maximum and minimum fault currents1.5Transformer and cable impedances1.6Motor contribution1.7Inrush currents1.8Equipment damage curves1.9Critical loads and priorities1.10Case study: modelling an industrial 20 kV network
2.1IEC normal inverse and very inverse curves2.2IEEE and user-defined curves2.3Expulsion fuses and current-limiting fuses2.4Low-voltage circuit breaker characteristics2.5ANSI transformer points2.6Log-log scale representation2.7Coordination margins2.8Time grading2.9Instantaneous unit settings2.10Workshop: plotting curves on log-log paper
3.1Coordination between relays in series3.2Relay-fuse coordination3.3Recloser and fuse saving3.4Logic selectivity by blocking3.5Directional selectivity in ring networks3.6MV/LV transformer protection3.7Medium-voltage motor protection3.8Capacitor bank protection3.9Coordination with the distribution utility's supply connection3.10Practice: 20 kV feeder with recloser
4.1Amperometric selectivity between circuit breakers4.2Chronometric selectivity with time delays4.3Energy selectivity in current-limiting circuit breakers4.4Back-up or cascade protection4.5Manufacturers' selectivity tables4.6Residual current device coordination4.7Main and sub-distribution boards4.8Generators and UPS systems4.9Contactors and thermal relays4.10Case study: selectivity in a commercial building
5.1Studies using specialist software5.2Coordination reports5.3Validation with event logs5.4Review after extensions5.5Analysis of spurious trips5.6Protection audits5.7Primary injection testing5.8Document management of settings5.9Relationship with the arc flash study5.10Laboratory: coordination study in ETAP
6.1Collecting installation data6.2MV/LV network model6.3Short-circuit calculation6.4Device selection6.5Settings and coordinated curves6.6Selectivity verification6.7Improvement recommendations6.8Final settings table6.9Report and presentation6.10Final review with the tutor
How you'll learn
100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetable: students progress at their own pace within the intake, which makes it compatible with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is ETAP, SKM PowerTools, EasyPower, Schneider Electric Ecodial, DIgSILENT PowerFactory, in free, academic or evaluation versions. The exercises work through real procedures for plotting and verifying time-current curves, selectivity studies in industrial installations and analysis of spurious trips. Assessment is continuous across modules, plus a final integrating project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Collect and model the data required for a coordination study.
Calculate maximum and minimum short-circuit currents according to IEC 60909.
Interpret and plot time-current curves for relays, fuses and circuit breakers.
Coordinate medium-voltage protection with adequate margins.
Ensure full or partial selectivity in low-voltage installations.
Where this takes you
Requirements
- No prior degree is required.
- Internet connection and a computer capable of running the programme's software.
- Sufficient level of Spanish to follow technical standards reading.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 300 hours, spread over 3 to 5 months. That is between 10 and 15 hours per week on average, compatible with a full-time job.
The programme uses ETAP, SKM PowerTools, EasyPower, Schneider Electric Ecodial, DIgSILENT PowerFactory. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.
SEIUM's own diploma upon passing continuous assessment and the integrating project. It is in-house training, not an official Ministry qualification.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Check the recognition policy when you enrol.
Related programmes
Course in Fuel Consumption Prediction Using AI
Online 300-hour course in fuel consumption prediction using AI. 6 modules covering ISO 19030, ISO 15016 and Python with scikit-learn. Assigned tutor and open enrolment.
Forestry Machinery Operation Course
Online 300-hour course in forestry machinery operation. 6 modules covering EN ISO 11850 (self-propelled forestry machinery, safety), ISO 8082-1 (roll-over protective structures on forestry machinery) and…
Course in Environmental Impact Assessment in CBRN Areas
Online 300-hour course in environmental impact assessment in CBRN areas. 6 modules covering Directive 2011/92/EU (environmental impact assessment), Law 21/2013 on environmental assessment and RESRAD (Argonne).…
More in Naval, Offshore & Sports Nautical
All Naval, Offshore & Sports Nautical programmes → · How to apply · Fees & financing · Scholarships