Postgraduate DiplomaAutonomous, ADAS & Software-Defined Vehicle Applications open

Postgraduate Diploma in UDS/OBD Diagnostics, Health Monitoring and FOTA

Online 800-hour Postgraduate Diploma in UDS/OBD diagnostics, Health Monitoring and FOTA. 8 modules covering ISO 14229-1:2020, ISO 15765-2:2024 and Vector CANoe. Assigned tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Understand the vehicle diagnostic architecture.

02

Apply the services of the UDS protocol.

03

Interpret the legal requirements of OBD.

04

Design health monitoring for embedded systems.

05

Implement remote diagnostic services while respecting privacy.

06

Plan robust FOTA reprogramming.

07

Validate diagnostic specifications in an automated way.

Profile

Who it's for

  • Diagnostics engineer who wants to specialise in UDS/OBD Diagnostics, Health Monitoring and FOTA.
  • OBD engineer who wants to specialise in UDS/OBD Diagnostics, Health Monitoring and FOTA.
  • Bootloader software engineer who wants to specialise in UDS/OBD Diagnostics, Health Monitoring and FOTA.
  • Diagnostics validation engineer who wants to specialise in UDS/OBD Diagnostics, Health Monitoring and FOTA.
  • Remote diagnostics specialist who wants to specialise in UDS/OBD Diagnostics, Health Monitoring and FOTA.
  • Advanced aftersales technician who wants to specialise in UDS/OBD Diagnostics, Health Monitoring and FOTA.
  • Graduates in engineering or science who want to join automotive manufacturers.
Standards & tools

What you'll work with

  • ISO 14229-1:2020
  • ISO 15765-2:2024
  • ISO 13400
  • SAE J1979-2
  • ISO 27145
  • ISO 22901-1
  • ISO 20078
  • UNECE R156
Syllabus

8 modules · 800 h

  1. 1.1On-board and off-board diagnostics
  2. 1.2Diagnostic communication stack
  3. 1.3ISO-TP transport over CAN per ISO 15765-2
  4. 1.4IP-based diagnostics with DoIP ISO 13400
  5. 1.5Diagnostic event manager in AUTOSAR
  6. 1.6Diagnostic trouble codes (DTC) and their structure
  7. 1.7Freeze frame data and extended records
  8. 1.8Distributed diagnostics in zonal architectures
  9. 1.9Workshop diagnostic tools
  10. 1.10Case study: diagnostic map of a zonal architecture
  1. 2.1Client-server model of ISO 14229-1
  2. 2.2Diagnostic sessions and timers
  3. 2.3Read and write by identifier
  4. 2.4DTC management: reading and clearing
  5. 2.5Routine control and actuator tests
  6. 2.6Data transfer for reprogramming
  7. 2.7Diagnostic access control and authentication
  8. 2.8Negative responses and their interpretation
  9. 2.9Diagnostic description with ODX ISO 22901
  10. 2.10Laboratory: UDS session with Vector CANoe
  1. 3.1Origin and obligations of OBD
  2. 3.2Modes and PIDs of SAE J1979
  3. 3.3OBD with UDS per SAE J1979-2
  4. 3.4WWH-OBD per ISO 27145
  5. 3.5Emission monitors and readiness
  6. 3.6Malfunction indicator lamp (MIL)
  7. 3.7Access to repair information (RMI)
  8. 3.8OBD in electric vehicles
  9. 3.9OBD in heavy-duty vehicles with SAE J1939
  10. 3.10Practice: reading OBD monitors of a test vehicle
  1. 4.1Health monitoring of ECUs and sensors
  2. 4.2Health indicators for batteries and actuators
  3. 4.3Detection of ADAS sensor degradation
  4. 4.4Ageing and cycle counters
  5. 4.5Network diagnostics and message loss
  6. 4.6Vehicle-level health aggregation
  7. 4.7Thresholds, hysteresis and filtering
  8. 4.8Health reporting to the backend
  9. 4.9Relationship with functional safety
  10. 4.10Workshop: health model of a front camera
  1. 5.1Remote diagnostic architectures
  2. 5.2Extended vehicle access per ISO 20078
  3. 5.3Remote reading of DTCs and status data
  4. 5.4Predictive diagnostics in the backend
  5. 5.5Owner privacy and consent
  6. 5.6Remote access security
  7. 5.7Integration with aftersales service
  8. 5.8Reducing workshop visits
  9. 5.9Effectiveness indicators
  10. 5.10Case study: remote diagnostic service for a van fleet
  1. 6.1UDS reprogramming sequence
  2. 6.2Bootloaders and memory partitions
  3. 6.3Integrity and signature verification
  4. 6.4FOTA versus workshop reprogramming
  5. 6.5Preconditions: battery, status and speed
  6. 6.6Parallel reprogramming of multiple ECUs
  7. 6.7Recovery from programming failures
  8. 6.8UNECE R156 requirements
  9. 6.9Reprogramming record
  10. 6.10Practice: UDS reprogramming sequence on the bench
  1. 7.1Diagnostic requirements specification
  2. 7.2UDS conformance testing
  3. 7.3Fault injection to generate DTCs
  4. 7.4Validation of ODX against the ECU
  5. 7.5OBD tests for type approval
  6. 7.6Automation of diagnostic testing
  7. 7.7Change management in the specification
  8. 7.8Interoperability testing with workshop tools
  9. 7.9Validation reports
  10. 7.10Laboratory: automated diagnostic test suite
  1. 8.1Selection of the ECU or system
  2. 8.2Diagnostic specification
  3. 8.3UDS services design
  4. 8.4Applicable OBD requirements
  5. 8.5Health monitoring model
  6. 8.6FOTA process
  7. 8.7Validation plan
  8. 8.8Technical report
  9. 8.9Written report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

100% online training on the SEIUM Institute campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: students progress at their own pace within the intake, which makes it possible to combine the programme with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Vector CANoe, Vector CANdelaStudio, Softing DTS, ETAS INCA, python-udsoncan, in free, academic or evaluation versions. Tests are studied using real procedures of UDS diagnostic sessions on the bench, OBD conformity tests and ECU reprogramming with integrity verification. Assessment is continuous per module plus the final integrating project.

Accreditable laboratories(EN ISO/IEC 17025) with rotor bench, EMC/Lightning pre-compliance, HIL/SIL, vibrations/acoustics.
Evidence-oriented Master's Thesis:safety case, test plan, compliance dossier and operational limits.
Industry Mentored:teachers with experience in training, , eVTOL/UAM and flight test.
Flexible modality(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:safety-by-design approach, cyber-OT, DIH and compliance as pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

ECU or system selection

Understand the vehicle diagnostic architecture.

Diagnostic specification

Apply the services of the UDS protocol.

UDS services design

Interpret the legal requirements of OBD.

Applicable OBD requirements

Design health monitoring for embedded systems.

Health monitoring model

Implement remote diagnostic services while respecting privacy.

Career opportunities

Where this takes you

Diagnostics engineerOBD engineerBootloader software engineerDiagnostics validation engineerRemote diagnostics specialistAdvanced aftersales technician
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. A university degree is not required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient Spanish to follow the reading of technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours spread over 6 to 8 months. That is between 10 and 15 hours per week on average, compatible with full-time work.

You work with Vector CANoe, Vector CANdelaStudio, Softing DTS, ETAS INCA, python-udsoncan. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM Institute own diploma upon passing continuous assessment and the integrating project. It is in-house training, not an official Ministry qualification.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised towards the advanced programme. Check the recognition policy when you enrol.

Postgraduate Diploma in UDS/OBD Diagnostics, Health Monitoring and FOTAEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.