Postgraduate DiplomaRobotics, Automation & Control Applications open

Postgraduate Diploma in Secure OT/IT Integration with MQTT

Online 800-hour Postgraduate Diploma in Secure OT/IT Integration with MQTT. 8 modules covering ISO/IEC 20922, OASIS MQTT Version 5.0 and Eclipse Mosquitto. Assigned tutor and open enrolment.

Duration800 h
ModeOnline
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Analyse the risks and requirements of OT/IT convergence.

02

Master the operation of the MQTT protocol and its QoS levels.

03

Model industrial data with Sparkplug B.

04

Configure MQTT brokers with TLS, certificates and access control.

05

Design secure integration architectures between plant and cloud.

06

Monitor and respond to incidents in IIoT integrations.

07

Meet the requirements of NIS2 and the Cyber Resilience Act.

Profile

Who it's for

  • OT/IT integration engineer who wants to specialise in Secure OT/IT Integration with MQTT.
  • Industrial cybersecurity specialist who wants to specialise in Secure OT/IT Integration with MQTT.
  • IIoT architect who wants to specialise in Secure OT/IT Integration with MQTT.
  • Industrial network engineer who wants to specialise in Secure OT/IT Integration with MQTT.
  • Edge solutions developer who wants to specialise in Secure OT/IT Integration with MQTT.
  • Plant data engineer who wants to specialise in Secure OT/IT Integration with MQTT.
  • Graduates in engineering or sciences looking to enter discrete manufacturing.
Standards & tools

What you'll work with

  • ISO/IEC 20922
  • OASIS MQTT Version 5.0
  • Eclipse Sparkplug 3.0
  • IEC 62443-3-3
  • IEC 62443-4-2
  • Directiva (UE) 2022/2555
  • Reglamento (UE) 2024/2847
  • NIST SP 800-82
Syllabus

8 modules · 800 h

  1. 1.1Differences in requirements between OT and IT
  2. 1.2The Purdue model and its levels
  3. 1.3Vertical data flows in the plant
  4. 1.4The Unified Namespace as an architecture
  5. 1.5Risks of OT/IT connection
  6. 1.6Zones and conduits according to IEC 62443
  7. 1.7Industrial DMZ and boundary brokers
  8. 1.8Shared governance between OT and IT teams
  9. 1.9Inventory of assets and existing protocols
  10. 1.10Practical: mapping data flows of a plant
  1. 2.1Publish-subscribe model and broker
  2. 2.2Topic structure and wildcards
  3. 2.3QoS quality of service levels
  4. 2.4Persistent sessions and retained messages
  5. 2.5Last Will and Testament
  6. 2.6What's new in MQTT 5.0
  7. 2.7Mosquitto, HiveMQ and EMQX brokers
  8. 2.8Broker performance and scalability
  9. 2.9Topic design patterns for the plant
  10. 2.10Laboratory: deploying a Mosquitto broker
  1. 3.1Sparkplug B specification
  2. 3.2Edge nodes and devices
  3. 3.3Birth and death messages
  4. 3.4Session state management
  5. 3.5Encoding with Protocol Buffers
  6. 3.6Designing topic hierarchies
  7. 3.7PLC integration through gateways
  8. 3.8Tools compatible with Sparkplug
  9. 3.9Managing changes to metric definitions
  10. 3.10Workshop: Sparkplug edge node with Node-RED
  1. 4.1Transport encryption with TLS
  2. 4.2Authentication with X.509 certificates
  3. 4.3User and token authentication
  4. 4.4Access control lists by topic
  5. 4.5Key and certificate management
  6. 4.6Protection against denial of service
  7. 4.7Broker logging and auditing
  8. 4.8Hardening the broker server
  9. 4.9Security of MQTT clients on embedded devices
  10. 4.10Practical: broker with mutual TLS and ACLs
  1. 5.1Data diodes and unidirectional flow
  2. 5.2Bridges between OT and IT brokers
  3. 5.3OPC UA to MQTT gateways
  4. 5.4Segmentation with industrial firewalls
  5. 5.5Remote access for vendors
  6. 5.6Integration with cloud IoT platforms
  7. 5.7Architectures from edge to cloud
  8. 5.8Resilience patterns and local storage
  9. 5.9Data normalisation for IT consumption
  10. 5.10Laboratory: bridge between plant broker and cloud
  1. 6.1Monitoring brokers and clients
  2. 6.2Anomaly detection in MQTT traffic
  3. 6.3Traffic analysis with Wireshark
  4. 6.4Integration with SIEM
  5. 6.5Incident management in integrations
  6. 6.6Penetration testing in IIoT
  7. 6.7Vulnerability management
  8. 6.8Continuity of messaging service
  9. 6.9Message logging and data retention
  10. 6.10Case study: detecting a malicious client
  1. 7.1Requirements of the NIS2 Directive
  2. 7.2Requirements of the Cyber Resilience Act
  3. 7.3Product certification under IEC 62443-4-2
  4. 7.4NIST guidance for OT
  5. 7.5Evaluating software suppliers
  6. 7.6Architecture documentation
  7. 7.7Training mixed teams
  8. 7.8Roadmap for secure convergence
  9. 7.9Contracts and service level agreements
  10. 7.10Case study: auditing an MQTT integration
  1. 8.1Plant analysis and requirements
  2. 8.2Design of zones and conduits
  3. 8.3Topic model and Sparkplug
  4. 8.4Deployment of the secure broker
  5. 8.5Gateways and bridges to the cloud
  6. 8.6Monitoring plan
  7. 8.7Security testing
  8. 8.8Analysis of results
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetable: students progress at their own pace within the intake, which makes it possible to combine study with work.

Each module combines theory, guided reading of the original standard and applied exercises. The software used is Eclipse Mosquitto, HiveMQ, Node-RED, Wireshark, Ignition, in free, academic or evaluation versions. Tests are studied using real deployment procedures for MQTT brokers with mutual TLS, PLC integration via Sparkplug B, and secure bridges between plant and cloud. Assessment is continuous across each module plus the final integrating project.

Accredited laboratories(EN ISO/IEC 17025) with a rotor test rig, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-oriented thesis:safety case, test plan, compliance dossier and operational limits.
Industry-led mentoring:lecturers with track records in training, , eVTOL/UAM and flight test.
Flexible format(blended/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, with OT cyber security, DIH and compliance as its pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Plant analysis and requirements

Analyse the risks and requirements of OT/IT convergence.

Design of zones and conduits

Master the operation of the MQTT protocol and its QoS levels.

Topic model and Sparkplug

Model industrial data with Sparkplug B.

Deployment of the secure broker

Configure MQTT brokers with TLS, certificates and access control.

Gateways and bridges to the cloud

Design secure integration architectures between plant and cloud.

Career opportunities

Where this takes you

OT/IT Integration EngineerIndustrial Cybersecurity SpecialistIIoT ArchitectIndustrial Network EngineerEdge Solutions DeveloperPlant Data Engineer
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. A university degree is not required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient Spanish to follow technical standards documentation.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours, spread over 6 to 8 months. That is an average of 10 to 15 hours per week, compatible with a full-time job.

The programme uses Eclipse Mosquitto, HiveMQ, Node-RED, Wireshark and Ignition. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM own diploma upon passing the continuous assessment and the integrating project. This is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are credited towards the advanced programme. Check the credit transfer policy when you enrol.

Postgraduate Diploma in Secure OT/IT Integration with MQTTEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.