Postgraduate DiplomaCivil, Rail & Smart Cities Applications open

Postgraduate Diploma in Plant Design and Odour Control

Online 800-hour Postgraduate Diploma in Plant Design and Odour Control. 8 modules covering EN 13725 (determination of odour concentration by dynamic olfactometry), EN 16841-1 (field odour measurement: grid method) and AERMOD. Assigned tutor and enrolment open.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Describe odorous compounds and the mechanisms of odour perception.

02

Apply standardised odour measurement and characterisation techniques.

03

Model the atmospheric dispersion of odours and estimate their impact.

04

Design plants with containment and capture systems aimed at reducing odours.

05

Size biofilters and bioscrubbers for air treatment.

06

Select physicochemical treatments according to the emission profile.

07

Prepare an odour management plan in accordance with regulations.

Profile

Who it's for

  • Odour control engineer looking to specialise in Plant Design and Odour Control.
  • Olfactometry technician looking to specialise in Plant Design and Odour Control.
  • Air treatment engineer looking to specialise in Plant Design and Odour Control.
  • Environmental manager of a treatment plant looking to specialise in Plant Design and Odour Control.
  • Atmospheric dispersion consultant looking to specialise in Plant Design and Odour Control.
  • Designer of waste and wastewater treatment plants looking to specialise in Plant Design and Odour Control.
  • Graduates in engineering or science seeking to enter wastewater treatment.
Standards & tools

What you'll work with

  • EN 13725 (determination of odour concentration by dynamic olfactometry)
  • EN 16841-1 (field odour measurement: grid method)
  • Directive 2010/75/EU (industrial emissions)
  • Implementing Decision (EU) 2018/1147 (BAT in waste treatment)
  • VDI 3477 (biofiltration)
  • VDI 3883 (effects and assessment of odours)
  • Spanish Law 34/2007 on air quality and protection of the atmosphere
Syllabus

8 modules · 800 h

  1. 1.1Chemistry of odorous compounds
  2. 1.2Hydrogen sulphide and mercaptans
  3. 1.3Ammonia and amines
  4. 1.4Volatile organic compounds
  5. 1.5Olfactory perception and detection threshold
  6. 1.6Odour concentration in ouE/m³
  7. 1.7Hedonic tone, intensity and offensiveness
  8. 1.8Sources in WWTPs, composting and landfills
  9. 1.9Neighbourhood complaints and social conflict
  10. 1.10Case study: source inventory of a WWTP
  1. 2.1Dynamic olfactometry according to EN 13725
  2. 2.2Sampling from point and area sources
  3. 2.3Flux chamber and wind tunnel
  4. 2.4Gas chromatography and GC-MS
  5. 2.5Electronic noses
  6. 2.6Continuous H₂S monitoring
  7. 2.7Field inspection according to EN 16841
  8. 2.8Calculation of odour emission rates
  9. 2.9Nuisance surveys
  10. 2.10Laboratory: interpreting an olfactometry report
  1. 3.1Meteorology and atmospheric stability
  2. 3.2AERMOD Gaussian model
  3. 3.3CALPUFF Lagrangian model
  4. 3.4Percentiles and impact criteria
  5. 3.5Isodour maps
  6. 3.6Effect of topography and buildings
  7. 3.7Pre-processing of meteorological data
  8. 3.8Validation with field campaigns
  9. 3.9Emission reduction scenarios
  10. 3.10Practical: dispersion simulation with AERMOD
  1. 4.1Siting and distances to receptors
  2. 4.2Enclosure of emitting processes
  3. 4.3Covered pre-treatment
  4. 4.4Enclosed thickening and dewatering
  5. 4.5Storage of sludge and waste
  6. 4.6Ventilation and air changes per hour
  7. 4.7Ductwork and fan design
  8. 4.8Corrosion-resistant materials
  9. 4.9Control of industrial discharges to the sewer
  10. 4.10Workshop: air flow balance of a WWTP
  1. 5.1Organic bed biofilters
  2. 5.2Trickling biofilters
  3. 5.3Bioscrubbers
  4. 5.4Microbiology of sulphide oxidation
  5. 5.5Empty bed residence time
  6. 5.6Humidification and pH control
  7. 5.7Pressure drop and media life
  8. 5.8Combined removal of H₂S and VOCs
  9. 5.9Efficiencies and limitations
  10. 5.10Practical: sizing a biofilter
  1. 6.1Multi-stage chemical scrubbers
  2. 6.2Acid and alkaline-oxidative washing
  3. 6.3Adsorption on impregnated activated carbon
  4. 6.4Regenerative thermal oxidation
  5. 6.5Ionisation and ozone
  6. 6.6Combined treatment trains
  7. 6.7Neutralising agents and fogging
  8. 6.8Investment and operating costs
  9. 6.9Safety in handling reagents
  10. 6.10Case study: technology for a composting plant
  1. 7.1Spanish Law 34/2007 on air quality
  2. 7.2Odour immission criteria in other countries
  3. 7.3BREF for waste treatment
  4. 7.4Odour management plans
  5. 7.5Integrated environmental authorisation
  6. 7.6Complaint management and communication
  7. 7.7Maintenance of deodorisation systems
  8. 7.8Performance indicators
  9. 7.9Periodic odour audits
  10. 7.10Practical: odour management plan for a facility
  1. 8.1Description of the facility and receptors
  2. 8.2Inventory and quantification of emissions
  3. 8.3Modelling of current impact
  4. 8.4Containment and ventilation measures
  5. 8.5Selection and sizing of the treatment
  6. 8.6Impact assessment after measures
  7. 8.7Management and monitoring plan
  8. 8.8Investment and operating budget
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

Fully 100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the intake, which makes it possible to combine study with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is AERMOD, CALPUFF, AutoCAD, advanced Excel, QGIS, in free, academic or evaluation versions. Tests are studied using real dynamic olfactometry laboratory procedures, field odour inspections, and monitoring of biofilters and chemical scrubbers. Assessment is continuous per module plus the final integrative project.

Accreditable laboratories(EN ISO/IEC 17025) with rotor test rig, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-driven Master's Thesis:safety case, test plan, compliance dossier and operating limits.
Industry mentoring:lecturers with track records in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, OT cyber, DIH and compliance as core pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Description of the facility and receptors

Describe odorous compounds and the mechanisms of odour perception.

Inventory and quantification of emissions

Apply standardised odour measurement and characterisation techniques.

Modelling of current impact

Model the atmospheric dispersion of odours and estimate their impact.

Containment and ventilation measures

Design plants with containment and capture systems aimed at reducing odours.

Selection and sizing of the treatment

Size biofilters and bioscrubbers for air treatment.

Career opportunities

Where this takes you

Odour control engineerOlfactometry technicianAir treatment engineerEnvironmental manager of a treatment plantAtmospheric dispersion consultantDesigner of waste and wastewater treatment plants
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient Spanish to follow technical standards documentation.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours spread over 6 to 8 months. That is an average of 10 to 15 hours per week, compatible with full-time work.

You work with AERMOD, CALPUFF, AutoCAD, advanced Excel and QGIS. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

SEIUM's own diploma upon passing the continuous assessment and the integrative project. It is in-house training, not an official Ministry qualification.

Yes. Modules passed in a Course or Postgraduate Diploma in the same area are recognised towards the higher-level programme. Check the recognition policy when you enrol.

Postgraduate Diploma in Plant Design and Odour ControlEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.