Postgraduate DiplomaEnergy and Networks Applications open

Postgraduate Diploma in Grid Codes and Compliance Testing

Online Postgraduate Diploma of 800 hours in Grid Codes and Compliance Testing. 8 modules covering Regulation (EU) 2016/631 (Requirements for Generators, RfG), Regulation (EU) 2016/1388 (Demand Connection Code, DCC) and DIgSILENT PowerFactory. Assigned tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Explain the framework of European network codes.

02

Apply technical requirements to generation modules.

03

Describe equipment certification processes.

04

Plan compliance field tests.

05

Validate simulation models with test results.

06

Analyse the requirements for demand, storage and HVDC.

07

Manage the connection procedure up to final notification.

Profile

Who it's for

  • Network code engineer who wants to specialise in Grid Codes and Compliance Testing.
  • Equipment certification engineer who wants to specialise in Grid Codes and Compliance Testing.
  • Compliance testing engineer who wants to specialise in Grid Codes and Compliance Testing.
  • Electrical modelling engineer who wants to specialise in Grid Codes and Compliance Testing.
  • Grid connection manager who wants to specialise in Grid Codes and Compliance Testing.
  • Renewable integration consultant who wants to specialise in Grid Codes and Compliance Testing.
  • Engineering or science graduates looking to enter renewable developers.
Standards & tools

What you'll work with

  • Regulation (EU) 2016/631 (Requirements for Generators, RfG)
  • Regulation (EU) 2016/1388 (Demand Connection Code, DCC)
  • Regulation (EU) 2016/1447 (HVDC connection)
  • Technical Supervision Standard NTS (Spain)
  • EN 50549-10 (generation compliance testing)
  • IEC 61400-21-1 (power quality of wind turbines)
  • FGW TR 3 (electrical characteristics testing)
Syllabus

8 modules · 800 h

  1. 1.1EU network codes package
  2. 1.2RfG Regulation 2016/631 for generators
  3. 1.3DCC Regulation on demand connection
  4. 1.4HVDC Regulation 2016/1447
  5. 1.5Classification of type A, B, C and D modules
  6. 1.6National implementation and NTS in Spain
  7. 1.7Non-exhaustive requirements and their specification
  8. 1.8Ongoing review of network codes
  9. 1.9Comparison with NERC and AEMO requirements
  10. 1.10Case study: classification of a hybrid plant
  1. 2.1Frequency and voltage ranges
  2. 2.2Limited frequency response LFSM-O and LFSM-U
  3. 2.3Frequency sensitive mode FSM
  4. 2.4Reactive power capability
  5. 2.5Voltage, reactive power and power factor control
  6. 2.6FRT fault ride-through capability
  7. 2.7Fast fault current injection
  8. 2.8Active power recovery after a fault
  9. 2.9Protection and interconnection requirements
  10. 2.10Practical: verification of an FRT curve
  1. 3.1Certification scheme for generating units
  2. 3.2Technical Supervision Standard NTS
  3. 3.3Accredited certification bodies
  4. 3.4Equipment and module certificates
  5. 3.5Validated simulation models
  6. 3.6Laboratory type tests
  7. 3.7Voltage dip testing with mobile equipment
  8. 3.8IEC 61400-21 and IEC 62116 standards
  9. 3.9Documentation for the operator
  10. 3.10Workshop: review of a unit certificate
  1. 4.1Compliance test plan
  2. 4.2Active power and ramp tests
  3. 4.3Voltage control tests
  4. 4.4Frequency response tests
  5. 4.5Reactive power capability tests
  6. 4.6Test instrumentation and recording
  7. 4.7Acceptance criteria and tolerances
  8. 4.8Management of non-conformities
  9. 4.9Final test report
  10. 4.10Laboratory: analysis of records from a frequency test
  1. 5.1Generic RMS models IEC 61400-27
  2. 5.2WECC models for renewables
  3. 5.3Manufacturer EMT models
  4. 5.4Model validation through testing
  5. 5.5Simulation in PowerFactory and PSS/E
  6. 5.6Simulation of the point of connection
  7. 5.7Stability studies for connection
  8. 5.8Aggregation of plant models
  9. 5.9Confidentiality of manufacturer models
  10. 5.10Practical: validation of a generic model
  1. 6.1DCC requirements for demand facilities
  2. 6.2Storage and its fit within RfG
  3. 6.3Demand response requirements
  4. 6.4Requirements for HVDC links
  5. 6.5DC-connected park modules
  6. 6.6Electrolysers and large loads
  7. 6.7Grid-forming in the code review
  8. 6.8Requirements for EV chargers
  9. 6.9Cybersecurity requirements
  10. 6.10Case study: requirements applicable to a 100 MW storage facility
  1. 7.1Operational notification: EON, ION and FON
  2. 7.2Phases of the commissioning procedure
  3. 7.3Coordination with the system operator
  4. 7.4Real-time data communication
  5. 7.5Exceptions and derogations
  6. 7.6Substantial modifications to installations
  7. 7.7Management of non-compliance
  8. 7.8Owner's responsibilities
  9. 7.9Timelines and process risks
  10. 7.10Workshop: compliance schedule for a solar park
  1. 8.1Definition of the installation and its type
  2. 8.2Identification of applicable requirements
  3. 8.3Analysis of equipment capabilities
  4. 8.4Certification plan
  5. 8.5Field test plan
  6. 8.6Simulation studies
  7. 8.7Document management with the operator
  8. 8.8Risk and timeline plan
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: students progress at their own pace within the intake, which makes it possible to combine the programme with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is DIgSILENT PowerFactory, PSCAD, PSS/E, MATLAB/Simulink, in free, academic or evaluation versions. Tests are studied using real field test procedures for generating modules, model validation simulations and voltage dip tests. Assessment is continuous per module plus the final integrating project.

Accreditable laboratories(EN ISO/IEC 17025) with a rotor test rig, EMC/Lightning pre-compliance, HIL/SIL and vibration/acoustics.
Evidence-focused final project:safety case, test plan, compliance dossier and operational limits.
Industry mentoring:lecturers with experience in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, cyber-OT, DIH and compliance as pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Definition of the installation and its type

Explain the framework of European network codes.

Identification of applicable requirements

Apply technical requirements to generation modules.

Analysis of equipment capabilities

Describe equipment certification processes.

Certification plan

Plan compliance field tests.

Field test plan

Validate simulation models with test results.

Career opportunities

Where this takes you

Network code engineerEquipment certification engineerCompliance testing engineerElectrical modelling engineerGrid connection managerRenewable integration consultant
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. A university degree is not required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient Spanish to follow technical standards reading.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours spread over 6 to 8 months. That is an average of 10 to 15 hours per week, compatible with full-time work.

You will work with DIgSILENT PowerFactory, PSCAD, PSS/E, MATLAB/Simulink. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

An own diploma from SEIUM Institute upon passing the continuous assessment and the integrating project. This is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher-level programme. Check the recognition policy when you enrol.

Postgraduate Diploma in Grid Codes and Compliance TestingEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.