Postgraduate DiplomaEnergy and Networks Applications open

Postgraduate Diploma in Degradation, O&M and Water Quality

Online 800-hour Postgraduate Diploma in Degradation, O&M and Water Quality. 8 modules with ISO 22734 (hydrogen generators by electrolysis), ISO 3696 (water for analytical use) and Python (pandas). Dedicated tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Identify the degradation mechanisms of alkaline and PEM electrolysers.

02

Define the quality requirements for feed water.

03

Manage the electrolyte and process loops.

04

Diagnose the condition of stacks through monitoring.

05

Plan the preventive and corrective maintenance of the plant.

06

Optimise operation to extend the service life of the electrolyser.

07

Assess the cost of O&M in the levelised cost of hydrogen.

Profile

Who it's for

  • Electrolyser operations engineer looking to specialise in Degradation, O&M and Water Quality.
  • Hydrogen plant maintenance technician looking to specialise in Degradation, O&M and Water Quality.
  • Water treatment specialist looking to specialise in Degradation, O&M and Water Quality.
  • Reliability engineer looking to specialise in Degradation, O&M and Water Quality.
  • Plant O&M manager looking to specialise in Degradation, O&M and Water Quality.
  • Electrochemical engineer looking to specialise in Degradation, O&M and Water Quality.
  • Engineering or science graduates seeking to enter green hydrogen.
Standards & tools

What you'll work with

  • ISO 22734 (hydrogen generators by electrolysis)
  • ISO 3696 (water for analytical use)
  • ASTM D1193 (reagent water)
  • ISO 14687 (hydrogen quality)
  • EN 13306 (maintenance terminology)
  • IEC 60812 (FMEA analysis)
  • ISO 55001 (asset management)
Syllabus

8 modules · 800 h

  1. 1.1PEM membrane degradation through thinning
  2. 1.2Dissolution and agglomeration of iridium and platinum
  3. 1.3Corrosion of porous transport layers
  4. 1.4Degradation of alkaline diaphragms
  5. 1.5Deactivation of nickel electrodes
  6. 1.6Effect of start-up and shutdown cycles
  7. 1.7Degradation from dynamic operation
  8. 1.8Degradation rates in µV/h
  9. 1.9End of stack life
  10. 1.10Case study: degradation analysis of a PEM stack
  1. 2.1Water requirements according to ASTM D1193
  2. 2.2Conductivity, TOC and silica
  3. 2.3Cationic impurities and poisoning
  4. 2.4Pretreatment: filtration and descalcification
  5. 2.5Double-pass reverse osmosis
  6. 2.6Electrodeionisation (EDI)
  7. 2.7Polishing with resins in the loop
  8. 2.8Seawater and desalination
  9. 2.9Water consumption per kilogram of hydrogen
  10. 2.10Laboratory: design of a water treatment train
  1. 3.1KOH concentration and carbonation
  2. 3.2Control of impurities in the electrolyte
  3. 3.3PEM water loop management
  4. 3.4Release of fluoride ions
  5. 3.5Filters and resins in circulation
  6. 3.6Gas cross-contamination
  7. 3.7Hydrogen purity according to ISO 14687
  8. 3.8Online analysers
  9. 3.9Sampling and laboratory analysis
  10. 3.10Practical: sampling plan for an alkaline electrolyser
  1. 4.1Cell voltage monitoring
  2. 4.2Electrochemical impedance spectroscopy
  3. 4.3Periodic polarisation curves
  4. 4.4Hydrogen crossover detection
  5. 4.5Thermography and hot spots
  6. 4.6Stack health indicators
  7. 4.7Data analytics and degradation models
  8. 4.8Digital twin for life prediction
  9. 4.9Early warnings and thresholds
  10. 4.10Workshop: analysis of cell voltages using real data
  1. 5.1Preventive, predictive and corrective strategies
  2. 5.2Maintenance plan according to the manufacturer
  3. 5.3Maintenance of pumps, valves and compressors
  4. 5.4Stack replacement and refurbishment
  5. 5.5Management of critical spare parts
  6. 5.6Planned shutdowns and their duration
  7. 5.7Safety in hydrogen work
  8. 5.8Work permits and isolation procedures
  9. 5.9Reliability-centred maintenance (RCM)
  10. 5.10Case study: RCM plan for a purification system
  1. 6.1Operating strategies that minimise degradation
  2. 6.2Current density limits
  3. 6.3Temperature and pressure management
  4. 6.4Standby modes and protection
  5. 6.5Trade-off between flexibility and service life
  6. 6.6Operation coupled with renewables
  7. 6.7Logging of hours and equivalent cycles
  8. 6.8Manufacturer performance guarantees
  9. 6.9LTSA service contracts
  10. 6.10Practical: operating strategy with degradation penalty
  1. 7.1O&M cost in the LCOH
  2. 7.2Stack replacement cost
  3. 7.3Availability and lost production
  4. 7.4Modelling degradation in the economic model
  5. 7.5KPI operating indicators
  6. 7.6Benchmarking between plants
  7. 7.7Outsourcing versus in-house O&M
  8. 7.8Staff training and competencies
  9. 7.9Contractual risks in guarantees
  10. 7.10Laboratory: impact of degradation on the LCOH
  1. 8.1Plant and technology characterisation
  2. 8.2Analysis of degradation mechanisms
  3. 8.3Design of the water treatment system
  4. 8.4Monitoring and diagnosis plan
  5. 8.5Maintenance plan
  6. 8.6Operating strategy
  7. 8.7Economic assessment of O&M
  8. 8.8Monitoring indicators
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable material, recorded classes and a dedicated technical tutor. No fixed timetable: students progress at their own pace within the intake, which makes it possible to combine study with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Python (pandas), MATLAB, SAP PM, Power BI, in free, academic or evaluation versions. Tests are studied using real procedures for feed-water quality analysis, electrolyser polarisation curves and failure mode analysis. Assessment is continuous by module plus the final integrating project.

Accreditable laboratories(EN ISO/IEC 17025) with a rotor test bench, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-oriented Master's Thesis (final project):safety case, test plan, compliance dossier and operating limits.
Industry-mentored:lecturers with a track record in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:safety-by-design approach, cyber-OT, DIH and compliance as its core pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Plant and technology characterisation

Identify the degradation mechanisms of alkaline and PEM electrolysers.

Analysis of degradation mechanisms

Define the quality requirements for feed water.

Design of the water treatment system

Manage the electrolyte and process loops.

Monitoring and diagnosis plan

Diagnose the condition of stacks through monitoring.

Maintenance plan

Plan the preventive and corrective maintenance of the plant.

Career opportunities

Where this takes you

Electrolyser operations engineerHydrogen plant maintenance technicianWater treatment specialistReliability engineerPlant O&M managerElectrochemical engineer
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient level of Spanish to follow technical standards documentation.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme consists of 800 hours in total, spread over 6 to 8 months. That is an average of 10 to 15 hours per week, compatible with a full-time job.

The course uses Python (pandas), MATLAB, SAP PM and Power BI. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM own diploma upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are credited towards the advanced programme. Check the transfer policy when you enrol.

Postgraduate Diploma in Degradation, O&M and Water QualityEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.