Postgraduate DiplomaCivil, Rail & Smart Cities Applications open

Postgraduate Diploma in Alternative Water Harvesting (Fog and Urban Rainwater)

800-hour online Postgraduate Diploma in Alternative Water Harvesting (fog and urban rainwater). 8 modules covering UNE-EN 16941-1 (on-site rainwater harvesting systems), Directive 2000/60/EC (Water Framework Directive) and EPA SWMM. Assigned tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this programme. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Identify unconventional water resources.

02

Explain the physics of fog water harvesting.

03

Design fog collectors adapted to each site.

04

Size urban rainwater utilisation systems.

05

Integrate sustainable urban drainage solutions.

06

Define treatment according to the intended use of the water.

07

Assess the economic and social viability of a harvesting project.

Profile

Who it's for

  • Water resources engineer who wants to specialise in Alternative Water Harvesting (fog and urban rainwater).
  • Sustainable urban drainage technician who wants to specialise in Alternative Water Harvesting (fog and urban rainwater).
  • Water development cooperation consultant who wants to specialise in Alternative Water Harvesting (fog and urban rainwater).
  • Designer of rainwater utilisation systems who wants to specialise in Alternative Water Harvesting (fog and urban rainwater).
  • Municipal environmental technician who wants to specialise in Alternative Water Harvesting (fog and urban rainwater).
  • Community water project manager who wants to specialise in Alternative Water Harvesting (fog and urban rainwater).
  • Graduates in engineering or science seeking to enter water management.
Standards & tools

What you'll work with

  • UNE-EN 16941-1 (On-Site Rainwater Harvesting Systems)
  • Directive 2000/60/EC (Water Framework Directive)
  • Technical Building Code, DB HS 5 (Drainage)
  • Directive (EU) 2020/2184
  • EN 752 (Drain and Sewer Systems)
  • ISO 46001 (Water Efficiency Management)
Syllabus

8 modules · 800 h

  1. 1.1Water balance and urban water stress
  2. 1.2Typologies: fog, dew, rain and runoff
  3. 1.3Climatology of advective and orographic fogs
  4. 1.4Intensity-duration-frequency curves
  5. 1.5Atmospheric water quality
  6. 1.6Legal framework for stormwater use
  7. 1.7Rainwater harvesting systems under UNE-EN 16941-1
  8. 1.8Experiences in Chile, Peru, Morocco and the Canary Islands
  9. 1.9Manageable demands: irrigation, cisterns and consumption
  10. 1.10Case study: inventory of alternative resources in a city
  1. 2.1Droplet microphysics and liquid water content
  2. 2.2Aerodynamic and deposition efficiencies
  3. 2.3Raschel meshes and next-generation meshes
  4. 2.4Shading coefficient and porosity
  5. 2.5Biomimetic and hydrophobic surfaces
  6. 2.6Influence of wind speed and direction
  7. 2.7Dew harvesting by radiative cooling
  8. 2.8Atmospheric water generators by condensation
  9. 2.9Yields in litres per square metre per day
  10. 2.10Laboratory: mesh efficiency testing
  1. 3.1Site survey and selection
  2. 3.2Standard fog gauges and measurement campaigns
  3. 3.3Structure, anchorages and wind loads
  4. 3.4Gutters, pipework and storage tanks
  5. 3.5Large-area fog collectors
  6. 3.6Mesh maintenance and repair
  7. 3.7Durability against UV radiation and salinity
  8. 3.8Integration with reforestation
  9. 3.9Installation and operating costs
  10. 3.10Workshop: design of a fog collector field
  1. 4.1Catchment surfaces: roofs and pavements
  2. 4.2Runoff coefficients by material
  3. 4.3First-flush diversion devices
  4. 4.4Filtration and prior sedimentation
  5. 4.5Sizing the storage tank
  6. 4.6Pumping and dual supply
  7. 4.7Installations in residential buildings
  8. 4.8Public facilities and industrial estates
  9. 4.9Achievable potable water savings
  10. 4.10Practical: sizing a tank for a school
  1. 5.1Sustainable urban drainage systems
  2. 5.2Green and blue roofs
  3. 5.3Permeable pavements
  4. 5.4Infiltration trenches and vegetated swales
  5. 5.5Rain gardens and structural tree pits
  6. 5.6Detention ponds and wetlands
  7. 5.7Modelling with SWMM
  8. 5.8Urban aquifer recharge
  9. 5.9Control of first-flush pollution
  10. 5.10Case study: redesign of a street with SUDS
  1. 6.1Contaminants in fog and rainwater
  2. 6.2Microbiological risks in storage tanks
  3. 6.3Disinfection with UV and chlorine
  4. 6.4Small-scale membrane filtration
  5. 6.5Potable and non-potable uses according to quality
  6. 6.6Sanitary requirements of Royal Decree 3/2023
  7. 6.7Remineralisation of condensation water
  8. 6.8Legionella prevention in installations
  9. 6.9Self-monitoring plan
  10. 6.10Laboratory: analysis of urban rainwater samples
  1. 7.1Cost-benefit analysis of alternative systems
  2. 7.2Municipal tariffs and rebates
  3. 7.3Community management of fog collectors
  4. 7.4Sustainability indicators
  5. 7.5Maintenance and allocation of responsibilities
  6. 7.6Municipal stormwater ordinances
  7. 7.7Climate finance and cooperation
  8. 7.8Monitoring with IoT sensors
  9. 7.9Communication with users
  10. 7.10Case study: management model for a rural community
  1. 8.1Site and demand selection
  2. 8.2Climate analysis of fog and rainfall
  3. 8.3Choice of harvesting technologies
  4. 8.4Design of collection and storage
  5. 8.5Treatment according to intended use
  6. 8.6Budget and economic analysis
  7. 8.7Operation and maintenance plan
  8. 8.8Management model and indicators
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the intake, which makes it possible to combine the programme with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is EPA SWMM, QGIS, HEC-HMS, advanced Excel, R, in free, academic or evaluation versions. Tests are studied using real procedures from fog-gauge measurement campaigns, roof water balances and quality analysis of harvested water. Assessment is continuous by module plus the final integrating project.

Accredited laboratories(EN ISO/IEC 17025) with rotor test rig, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-oriented final project:safety case, test plan, compliance dossier and operational limits.
Industry mentoring:lecturers with track records in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, with OT cyber-security, DIH and compliance as its pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Site and demand selection

Identify unconventional water resources.

Climate analysis of fog and rainfall

Explain the physics of fog water harvesting.

Choice of harvesting technologies

Design fog collectors adapted to each site.

Design of collection and storage

Size urban rainwater utilisation systems.

Treatment according to intended use

Integrate sustainable urban drainage solutions.

Career opportunities

Where this takes you

Water resources engineerSustainable urban drainage technicianWater development cooperation consultantDesigner of rainwater utilisation systemsMunicipal environmental technicianCommunity water project manager
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. A university degree is not required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient command of Spanish to follow technical regulatory texts.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme comprises 800 hours in total, spread over 6 to 8 months. That is an average of 10 to 15 hours per week, compatible with a full-time job.

The programme works with EPA SWMM, QGIS, HEC-HMS, advanced Excel and R. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM own diploma upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area can be credited towards the advanced programme. Please check the recognition policy when you enrol.

Postgraduate Diploma in Alternative Water Harvesting (Fog and Urban Rainwater)Enrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.