NFPA/UL Safety for Stationary Batteries Course
Online 300-hour course in NFPA/UL safety for stationary batteries. 6 modules covering NFPA 855 (installation of stationary energy storage systems), UL 9540 (energy storage systems and equipment) and Fire Dynamics Simulator (FDS). Dedicated tutor and open enrolment.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Explain thermal runaway mechanisms and their consequences in lithium batteries.
Apply the requirements of NFPA 855 to stationary installations.
Interpret UL 9540 certifications and UL 9540A test results.
Select detection, suppression and deflagration control systems.
Develop emergency plans coordinated with fire services.
Establish safe procedures for operation, inspection and end of life.
Write the safety analysis of a battery installation.
Who it's for
- Fire protection engineer who wants to specialise in NFPA/UL Safety for Stationary Batteries.
- Battery safety specialist who wants to specialise in NFPA/UL Safety for Stationary Batteries.
- Occupational risk prevention technician who wants to specialise in NFPA/UL Safety for Stationary Batteries.
- Energy storage engineer who wants to specialise in NFPA/UL Safety for Stationary Batteries.
- Industrial safety inspector who wants to specialise in NFPA/UL Safety for Stationary Batteries.
- Risk consultant for insurers who wants to specialise in NFPA/UL Safety for Stationary Batteries.
- Graduates in engineering or sciences seeking to enter energy storage.
What you'll work with
- NFPA 855 (installation of stationary energy storage systems)
- UL 9540 (energy storage systems and equipment)
- UL 9540A (thermal runaway propagation test)
- UL 1973 (batteries for stationary use)
- NFPA 68 (explosion protection by deflagration venting)
- NFPA 69 (explosion prevention systems)
- IEC 62619 (safety of industrial lithium batteries)
- International Fire Code, section 1207
6 modules · 300 h
1.1Thermal runaway mechanisms1.2Vent gases and their composition1.3Explosion risk1.4Propagation between cells1.5Electrical, thermal and mechanical abuse1.6Differences between chemistries1.7Documented incidents in installations1.8Risks for firefighters1.9Re-ignition risk1.10Case study: the McMicken incident of 2019
2.1Scope and application thresholds2.2Energy limits by group2.3Separation and spacing2.4Indoor and outdoor installations2.5Risk mitigation analysis2.6Ventilation and deflagration control2.7Detection and suppression2.8Emergency response plan2.9Dismantling and safe removal2.10Workshop: verifying compliance with NFPA 855
3.1UL 1973 for batteries3.2UL 9540 for systems3.3UL 9540A methodology3.4Tests at cell, module, unit and installation level3.5Interpreting 9540A reports3.6UL 1741 for inverters3.7Certification versus listing3.8Relationship with IEC 626193.9Third-party assessment3.10Practice: critical reading of a UL 9540A report
4.1Gas and smoke detection4.2Early off-gas detection4.3Clean agent suppression4.4Water mist and cooling4.5Explosion relief panels4.6Mechanical extraction ventilation4.7Fire barriers between units4.8BMS and electrical protections4.9Emergency shutdown4.10Case study: protecting a battery container
5.1Pre-incident plans with firefighters5.2Staff training5.3Inspection and maintenance5.4Remote monitoring of critical parameters5.5Management of damaged cells5.6Transport and storage5.7Recycling and second life5.8Insurer requirements5.9Safety audits5.10Laboratory: early warnings using BMS data
6.1Description of the installation6.2Hazard identification6.3Review of certifications6.4Prevention and protection measures6.5Consequence analysis6.6Emergency plan6.7Inspection plan6.8Conclusions of the safety analysis6.9Report and presentation6.10Final review with the tutor
How you'll learn
100% online training on the SEIUM campus, with downloadable material, recorded classes and a dedicated technical tutor. No fixed timetables: students progress at their own pace within the intake, making it possible to combine with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is Fire Dynamics Simulator (FDS), FLACS-CFD, Ansys Fluent, BowTieXP, in free, academic or evaluation versions. Tests are studied using real procedures for reviewing UL 9540A test reports, risk analysis of battery containers, and response plans with fire services. Assessment is continuous per module plus the final integrating project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Explain thermal runaway mechanisms and their consequences in lithium batteries.
Apply the requirements of NFPA 855 to stationary installations.
Interpret UL 9540 certifications and UL 9540A test results.
Select detection, suppression and deflagration control systems.
Develop emergency plans coordinated with fire services.
Where this takes you
Requirements
- No prior degree is required.
- Internet connection and a computer capable of running the programme's software.
- Sufficient Spanish to follow the reading of technical standards.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 300 hours spread over 3 to 5 months. That is an average of between 10 and 15 hours per week, compatible with full-time work.
You will work with Fire Dynamics Simulator (FDS), FLACS-CFD, Ansys Fluent, BowTieXP. Free, academic or evaluation versions are used, and the tutor will indicate the free alternative where one exists.
An own-award diploma from SEIUM on passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the advanced programme. Check the module recognition policy when you enrol.
Related programmes
Course in Business Models for Energy Communities
Online 300-hour course in business models for energy communities. 6 modules covering Directive (EU) 2018/2001 (promotion of renewables, renewable energy communities), Directive (EU) 2019/944 (citizen energy…
Course in Thermal Management in Storage Systems
The Course in Thermal Management in Storage Systems focuses on the design and optimisation of thermal management for energy storage systems. It explores the use of…
Multi-terminal and Offshore Links Course
Online course of 300 h in multi-terminal and offshore links. 6 modules covering Regulation (EU) 2016/1447 (HVDC), IEC 62747 and PSCAD. Assigned tutor and open enrolment.
More in Energy and Networks
All Energy and Networks programmes → · How to apply · Fees & financing · Scholarships