Course in Power Quality Management in Low Voltage
Online 300-hour course in power quality management in low voltage. 6 modules covering EN 50160 (characteristics of the supplied voltage), IEC 61000-4-30 (power quality measurement methods) and Fluke Energy Analyze Plus. Dedicated tutor and open enrolment.
Take the controls.
Run a real engineering trade-off from this programme. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Identify and classify power quality disturbances in low-voltage networks.
Plan measurement campaigns using analysers compliant with IEC 61000-4-30.
Interpret records of dips, flicker, unbalance and harmonics.
Diagnose the origin of supply quality problems.
Select technically and economically viable mitigation solutions.
Apply the limits and regulatory responsibilities for quality of service.
Prepare a power quality management plan for an installation.
Who it's for
- Power quality engineer wishing to specialise in Power Quality Management in Low Voltage.
- Electrical measurement technician wishing to specialise in Power Quality Management in Low Voltage.
- Electrical maintenance manager wishing to specialise in Power Quality Management in Low Voltage.
- Distribution engineer wishing to specialise in Power Quality Management in Low Voltage.
- Energy efficiency consultant wishing to specialise in Power Quality Management in Low Voltage.
- Electrical installation auditor wishing to specialise in Power Quality Management in Low Voltage.
- Engineering or science graduates looking to enter industry.
What you'll work with
- EN 50160 (characteristics of the supplied voltage)
- IEC 61000-4-30 (power quality measurement methods)
- IEEE 1159 (power quality monitoring)
- IEC 61000-4-7 (measurement of harmonics and interharmonics)
- IEC 61000-4-15 (flickermeter)
- IEC 61000-2-2 (compatibility levels in low-voltage networks)
- IEC 61000-3-2 (limits for harmonic current emissions)
- Royal Decree 1955/2000 (quality of service)
6 modules · 300 h
1.1Slow voltage variations1.2Dips and short interruptions1.3Switching transient overvoltages1.4Flicker and fluctuations1.5Voltage unbalance1.6Harmonics and interharmonics1.7Frequency variations1.8Network signalling1.9Costs of poor quality1.10Case study: production stoppages caused by dips
2.1Class A analysers2.2IEC 61000-4-30 methods2.3Harmonic measurement according to IEC 61000-4-72.4Flickermeter according to IEC 61000-4-152.5Location of measurement points2.6Temporary measurement campaigns2.7Permanent monitoring at main distribution boards2.8Weekly statistical indices2.9EN 50160 compliance reports2.10Workshop: measurement campaign with a portable analyser
3.1Identification of disturbance sources3.2Non-linear loads in buildings3.3Resonances with capacitors3.4Neutral conductor overload3.5Earthing problems3.6Equipment susceptibility3.7ITIC and SEMI F47 curves3.8Root cause analysis3.9Responsibility between customer and distributor3.10Practice: diagnosis from real records
4.1Uninterruptible power supplies4.2Dynamic voltage restorers4.3Voltage stabilisers4.4Reactive power compensation4.5Balancing single-phase loads4.6Isolation transformers4.7Surge protection4.8Neutral and earth design4.9Selection of immune equipment4.10Case study: solution for a data centre
5.1Electromagnetic compatibility levels5.2Equipment emission limits5.3Regulated quality of service5.4Complaints and compensation5.5Supply quality contracts5.6Power quality management plan5.7Power quality in energy audits5.8Training of maintenance staff5.9Monitoring indicators5.10Laboratory: simulation of a dip and its mitigation
6.1Description of the installation6.2Measurement plan6.3Record analysis6.4Diagnosis of disturbances6.5Selection of solutions6.6Techno-economic evaluation of solutions6.7Monitoring plan6.8Conclusions and action plan6.9Report and presentation6.10Final review with the tutor
How you'll learn
Training 100 % online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: students progress at their own pace within the intake, which makes it possible to combine study with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is Fluke Energy Analyze Plus, PQView, Dranetz Dran-View, MATLAB/Simulink, ETAP, in free, academic or evaluation versions. Tests are studied using real measurement campaign procedures with class A analysers, diagnosis of dips and overvoltages, and assessment of compliance with EN 50160. Assessment is continuous, module by module, plus the final integrating project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Identify and classify power quality disturbances in low-voltage networks.
Plan measurement campaigns using analysers compliant with IEC 61000-4-30.
Interpret records of dips, flicker, unbalance and harmonics.
Diagnose the origin of supply quality problems.
Select technically and economically viable mitigation solutions.
Where this takes you
Requirements
- No prior degree required.
- Internet connection and a computer capable of running the programme’s software.
- Sufficient Spanish to follow technical standards documentation.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme comprises 300 hours in total, spread over 3 to 5 months. That is between 10 and 15 hours per week on average, compatible with full-time work.
The programme uses Fluke Energy Analyze Plus, PQView, Dranetz Dran-View, MATLAB/Simulink and ETAP. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.
A SEIUM own diploma upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised towards the higher programme. Check the recognition policy when you enrol.
Related programmes
Multi-terminal and Offshore Links Course
Online course of 300 h in multi-terminal and offshore links. 6 modules covering Regulation (EU) 2016/1447 (HVDC), IEC 62747 and PSCAD. Assigned tutor and open enrolment.
Course in NATO Standards for Heavy Mobility
300-hour online course in NATO standards for heavy mobility. 6 modules with STANAG 2021 (military load classification, MLC), MIL-STD-1366 (transportability criteria) and AutoTURN. Assigned tutor and…
Course in Ethics in Military Energy Autonomy
Online 300-hour course in ethics in military energy autonomy. 6 modules covering ISO 50001:2018 (energy management), Directive (EU) 2023/1791 (energy efficiency) and HOMER Pro. Assigned tutor…
More in Energy and Networks
All Energy and Networks programmes → · How to apply · Fees & financing · Scholarships