Master’s in Wearables, Biosensors & Data Engineering
Online master's programme of 1,900 hours in wearables, biosensors and data engineering: 12 modules covering the wearables ecosystem, sensors, embedded hardware, connectivity, physiological signal processing, analytics and machine learning, cloud data platforms, privacy and cybersecurity, validation, medical wearable regulation and user-centred design, with Regulation (EU) 2017/745, GDPR and Python, with an assigned technical tutor.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Select suitable sensors to measure physiological variables in wearables.
Design low-power hardware and connectivity architectures.
Process physiological signals and extract reliable indicators.
Apply machine learning to wearable data with rigorous validation.
Build interoperable data platforms based on HL7 FHIR.
Ensure the privacy and cybersecurity of health data.
Define the regulatory strategy for a medical wearable under the MDR.
Who it's for
- Wearable engineers developing consumer and medical devices.
- Health data scientists.
- Biomedical firmware developers.
- Digital clinical validation engineers.
- Health data privacy specialists.
- Digital health product managers.
- Engineering or science graduates looking to enter digital health.
What you'll work with
- Regulation (EU) 2017/745 (medical devices regulation (MDR))
- Regulation (EU) 2016/679 (GDPR) (protection of personal data)
- ISO 14971 (risk management for medical devices)
- IEC 62304 (medical device software life cycle)
- IEC 60601-1-11 (medical equipment for the home healthcare environment)
- ISO/IEEE 11073 (personal health device communication)
- HL7 FHIR R4 (health data interoperability standard)
- IEC 81001-5-1 (cybersecurity of health software)
- Python with pandas and scikit-learn
- MATLAB
- Nordic nRF Connect SDK
- InfluxDB
- Edge Impulse
12 modules · 1900 h
1.1Classification by body location1.2Consumer and medical-grade wearables1.3The data value chain1.4Architecture from sensor to cloud1.5Business and reimbursement models1.6Use cases in health and sport1.7Barriers to adoption and adherence1.8Trends in rings and patches1.9Wearables in decentralised clinical trials1.10Case study: analysis of a commercial wearable
2.1MEMS accelerometers and gyroscopes2.2Wrist-worn photoplethysmography (PPG)2.3Electrocardiography with dry electrodes2.4Bioimpedance and electrodermal activity2.5Skin temperature and thermal sensors2.6Chemical sensors in sweat2.7Barometers and magnetometers2.8Noise, drift and calibration2.9Eye movement sensors and portable EEG2.10Lab: characterisation of a PPG sensor
3.1Low-power ARM Cortex-M microcontrollers3.2Analogue front ends for biopotentials3.3Analogue-to-digital conversion and sampling3.4Power and battery management3.5Flexible PCB design3.6Encapsulation and IP sealing3.7Electromagnetic compatibility under IEC 60601-1-23.8Biocompatibility of skin-contact materials3.9Selection of batteries and wireless chargers3.10Practical: prototype with nRF52 and an inertial sensor
4.1Bluetooth Low Energy and GATT profiles4.2IEEE 11073 protocols4.3Wi-Fi, NFC and LPWAN4.4Time synchronisation of data4.5On-device compression and processing4.6Mobile gateways and apps4.7Reliability and packet loss4.8Radio power consumption4.9Bluetooth pairing security4.10Workshop: BLE heart rate service
5.1FIR and IIR digital filtering5.2Peak detection in ECG and PPG5.3Time-domain and spectral HRV indices5.4SpO2 estimation5.5Motion artefact reduction5.6Sensor fusion with Kalman filters5.7Segmentation and time windows5.8Feature extraction5.9Step and cadence detection5.10Practical: HRV from a PPG recording
6.1Human activity recognition6.2Fall detection6.3Sleep classification6.4Time series models6.5Convolutional and recurrent networks6.6Validation with independent subjects6.7Bias by skin tone and population6.8Model explainability6.9Anomaly detection in longitudinal trends6.10Lab: activity classifier with IMU data
7.1Ingestion and storage of time series7.2Streaming architectures7.3Time series databases7.4Interoperability with HL7 FHIR7.5Open mHealth and data schemas7.6Dashboards for clinicians and users7.7Scalability and costs7.8Apple HealthKit and Health Connect APIs7.9Data governance and quality on platforms7.10Practical: cloud ingestion pipeline
8.1GDPR and health data8.2Consent and data minimisation8.3Anonymisation and pseudonymisation8.4On-device and in-transit encryption8.5BLE vulnerabilities8.6Security under IEC 81001-5-18.7Data protection impact assessment8.8Security incident management8.9Retention policies and user rights8.10Workshop: impact assessment of a wearable
9.1Technical validation studies9.2Bland–Altman analysis9.3Verification, analytical and clinical validation studies9.4Design of real-world studies9.5Digital endpoints and biomarkers9.6Handling missing data9.7Reproducibility and reporting standards9.8Evidence for payers9.9Digital endpoints accepted by the EMA9.10Practical: comparing a wearable against a Holter ECG
10.1Regulation (EU) 2017/745 and classification10.2Rule 11 for software10.3Software as a medical device10.4Risk management under ISO 1497110.5IEC 60601-1-11 for home use10.6IEC 62304 software life cycle10.7CE marking and notified bodies10.8Post-market surveillance and PSUR10.9FDA 510(k) and De Novo pathways10.10Case study: classification of an ECG patch
11.1Usability and IEC 62366-111.2Interface design for small screens11.3Ergonomics and comfort in prolonged use11.4Adherence and behaviour change techniques11.5Accessibility for older people11.6Haptic feedback and notifications11.7User studies11.8Inclusive algorithm design11.9Packaging design and user onboarding11.10Workshop: interface prototype for a wristband
12.1Definition of the use case and user12.2Requirements specification12.3Hardware design or sensor selection12.4Development of the data pipeline12.5Analytical model and validation12.6Privacy and security analysis12.7Product regulatory strategy12.8User evaluation plan12.9Master's Thesis report12.10Master's Thesis: defence before a panel
How you'll learn
100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: you progress at your own pace within the intake, so it is compatible with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is Python with pandas and scikit-learn, MATLAB, Nordic nRF Connect SDK, InfluxDB and Edge Impulse, in free, academic or evaluation versions. Practical work is based on real procedures for validating wearables against reference equipment, real-world data collection with volunteers and prototyping devices with BLE connectivity. Assessment is continuous by module, plus the final Master's Thesis.
Standards covered: Regulation (EU) 2017/745, Regulation (EU) 2016/679 (GDPR), ISO 14971, IEC 62304, IEC 60601-1-11, ISO/IEEE 11073, HL7 FHIR R4, IEC 81001-5-1.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Where this takes you
Requirements
- A university degree in engineering, science or architecture, or equivalent demonstrable professional experience.
- An internet connection and a computer capable of running the programme's software.
- English sufficient to read technical standards.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.
You work with Python with pandas and scikit-learn, MATLAB, Nordic nRF Connect SDK, InfluxDB and Edge Impulse, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.
A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.
A university degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the programme's software, and English sufficient to read technical standards.
Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.
Related programmes
Master’s in Ergonomics & Human Factors Engineering (Transport/Industry)
Online master's programme of 1,900 hours in ergonomics and human factors engineering for transport and industry. 12 modules covering sociotechnical systems, cabs and driving positions, control…
Master’s in Decentralised Trials and Remote Monitoring Engineering
Online master's programme of 1,900 hours in decentralised trials and remote monitoring engineering. 12 modules covering decentralised clinical trials, GCP regulation, clinical wearables, digital biomarkers, monitoring…
Master’s in Assistive Robotics and Home Automation Engineering for Dependent Care
Online master's programme of 1,900 hours in assistive robotics and home automation for dependency. 12 modules covering dependency and technology, assistive and service robotics, perception and…
More in Health, Biomechanics, Wearables & Operational Safety
All Health, Biomechanics, Wearables & Operational Safety programmes → · How to apply · Fees & financing · Scholarships