Master'sHealth, Biomechanics, Wearables & Operational Safety Applications open

Master’s in Biosensors and Biosignal Processing Engineering

Online master's programme of 1,900 hours in biosensor engineering and biosignal processing. 12 modules covering electrochemical and optical biosensors, biopotential acquisition, ECG, EEG, EMG and PPG processing, machine learning, device integration and IVDR/MDR regulation, with an assigned technical tutor.

Duration1900 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Explain the transduction principles of biosensors.

02

Characterise electrochemical and optical biosensors in the laboratory.

03

Design safe biopotential acquisition chains.

04

Process ECG, EEG, EMG and PPG signals using digital techniques.

05

Apply validated machine learning to biosignals.

06

Integrate biosensors into devices with biocompatibility criteria.

07

Plan regulatory compliance under the MDR and IVDR.

Profile

Who it's for

  • Biosensor engineers looking to deepen their knowledge of signal processing and regulation.
  • Biomedical signal processing engineers moving towards sensor design.
  • In vitro diagnostics researchers.
  • Clinical algorithm developers.
  • IVD regulatory affairs specialists.
  • Biomedical hardware engineers.
  • Engineering or science graduates looking to enter in vitro diagnostics.
Standards & tools

What you'll work with

  • Regulation (EU) 2017/746 (in vitro diagnostic medical devices)
  • Regulation (EU) 2017/745 (medical devices)
  • ISO 15197 (blood-glucose self-testing systems)
  • ISO 13485 (quality management systems for medical devices)
  • IEC 60601-2-47 (ambulatory electrocardiographic systems)
  • ANSI/AAMI EC57 (testing of arrhythmia algorithms)
  • ISO 10993-1 (biological evaluation)
  • ISO 14971 (risk management)
  • MATLAB
  • Python with SciPy and NeuroKit2
  • EEGLAB
  • LabVIEW
  • COMSOL Multiphysics
Syllabus

12 modules · 1900 h

  1. 1.1Definition and architecture of a biosensor
  2. 1.2Biological recognition elements
  3. 1.3Electrochemical, optical and piezoelectric transducers
  4. 1.4Sensitivity, selectivity and limit of detection
  5. 1.5Calibration curves and dynamic range
  6. 1.6Stability, drift and shelf life
  7. 1.7Glucose biosensors as a reference
  8. 1.8Market and clinical applications
  9. 1.9Lactate and ketone biosensors
  10. 1.10Case study: analysis of a commercial glucometer
  1. 2.1Electrodes and three-electrode cells
  2. 2.2Amperometry and cyclic voltammetry
  3. 2.3Electrochemical impedance spectroscopy
  4. 2.4Second- and third-generation enzymatic sensors
  5. 2.5Immunosensors and aptasensors
  6. 2.6Low-cost screen-printed electrodes
  7. 2.7Nanomaterials for signal amplification
  8. 2.8Sweat and tear sensors
  9. 2.9Continuous interstitial glucose biosensors
  10. 2.10Laboratory: cyclic voltammetry with a potentiostat
  1. 3.1Surface plasmon resonance
  2. 3.2Fluorescence and chemiluminescence
  3. 3.3Optical fibre and waveguides
  4. 3.4Quartz crystal microbalance
  5. 3.5Paper-based colorimetric sensors
  6. 3.6Lateral flow tests
  7. 3.7Smartphone-based detection
  8. 3.8Point-of-care biosensors
  9. 3.9Graphene- and transistor-based biosensors
  10. 3.10Practical exercise: reading a lateral flow test
  1. 4.1Origin of ECG, EEG and EMG
  2. 4.2Electrode-skin interface impedance
  3. 4.3Instrumentation amplifiers for biopotentials
  4. 4.4Common-mode rejection and the right-leg drive circuit
  5. 4.5Isolation and electrical safety
  6. 4.6Dry and textile electrodes
  7. 4.7High-density acquisition
  8. 4.8IEC 60601-2-47 for ambulatory ECG recording
  9. 4.9Multi-frequency bioimpedance and body composition
  10. 4.10Laboratory: ECG front-end with the ADS1292
  1. 5.1Nyquist theorem and aliasing
  2. 5.2Quantisation and resolution
  3. 5.3Fourier transform and spectrograms
  4. 5.4FIR and IIR filters
  5. 5.5Mains interference filtering
  6. 5.6Resampling and synchronisation
  7. 5.7Windowing and spectral leakage
  8. 5.8EDF and WFDB formats
  9. 5.9Outlier detection in signals
  10. 5.10Practical exercise: designing ECG filters in Python
  1. 6.1QRS detection with Pan-Tompkins
  2. 6.2Delineation of P and T waves
  3. 6.3RR series and non-linear analysis
  4. 6.4Atrial fibrillation detection
  5. 6.5ST segment analysis
  6. 6.6Signal quality and artefacts
  7. 6.7PhysioNet databases
  8. 6.8Validation with ANSI/AAMI EC57
  9. 6.9Ventricular arrhythmias and their detection
  10. 6.10Laboratory: QRS detector on MIT-BIH
  1. 7.1Brain rhythms and frequency bands
  2. 7.2Artefact removal with ICA
  3. 7.3Evoked potentials and averaging
  4. 7.4Non-invasive brain-computer interfaces
  5. 7.5EMG decomposition into motor units
  6. 7.6Muscle onset detection
  7. 7.7EMG fatigue indices
  8. 7.8Time-frequency analysis with wavelets
  9. 7.9EMG spectral bands and fatigue
  10. 7.10Practical exercise: state classification with EEG
  1. 8.1Photoplethysmography and SpO2
  2. 8.2Cuffless blood pressure
  3. 8.3Pulse transit time
  4. 8.4Capnography and respiratory signals
  5. 8.5Thoracic bioimpedance and cardiac output
  6. 8.6Phonocardiography and heart sounds
  7. 8.7Multimodal signal fusion
  8. 8.8Continuous monitoring in the ICU
  9. 8.9Reflective oximetry in wrist and ring devices
  10. 8.10Case study: respiratory estimation from PPG
  1. 9.1Classical feature extraction
  2. 9.21D convolutional networks
  3. 9.3Recurrent networks and transformers
  4. 9.4Learning with limited data
  5. 9.5Physiological data augmentation
  6. 9.6Subject-wise validation
  7. 9.7Explainability in clinical decisions
  8. 9.8Deployment on embedded devices
  9. 9.9Self-supervised learning on physiological signals
  10. 9.10Laboratory: 1D network for arrhythmias
  1. 10.1Embedded system architectures
  2. 10.2Real-time processing
  3. 10.3Power consumption and autonomy
  4. 10.4Microfluidics and lab-on-chip
  5. 10.5Biocompatible encapsulation and ISO 10993
  6. 10.6Sterilisation of biosensors
  7. 10.7Production and batch control
  8. 10.8Reliability of implantable sensors
  9. 10.9Wireless communication of implanted sensors
  10. 10.10Workshop: specification of a multisensor patch
  1. 11.1Regulation (EU) 2017/746 on in vitro diagnostics
  2. 11.2Regulation (EU) 2017/745 on medical devices
  3. 11.3ISO 13485 at biosensor manufacturers
  4. 11.4ISO 15197 for glucometers
  5. 11.5Analytical performance evaluation
  6. 11.6Risk management with ISO 14971
  7. 11.7Analysis software and IEC 62304
  8. 11.8Clinical performance studies
  9. 11.9Algorithm validation against annotated databases
  10. 11.10Case study: regulatory pathway for a POC test
  1. 12.1Clinical need and target biomarker
  2. 12.2Transduction selection and design
  3. 12.3Prototype fabrication or acquisition
  4. 12.4Analytical characterisation of the sensor
  5. 12.5Signal processing chain
  6. 12.6Interpretation algorithm
  7. 12.7Evaluation with samples or volunteers
  8. 12.8Regulatory and quality fit
  9. 12.9Thesis report
  10. 12.10Master's Thesis: defence before a panel
Methodology, software & labs

How you'll learn

Training is 100% online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within each intake, so the programme is compatible with full-time work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is MATLAB, Python with SciPy and NeuroKit2, EEGLAB, LabVIEW and COMSOL Multiphysics, in free, academic or evaluation versions. Testing is studied through real procedures: electrochemical characterisation with a potentiostat, processing of recordings from PhysioNet databases and design of analogue front-ends for biopotentials. Assessment is continuous by module, plus the final Master's Thesis.

Standards covered: Regulation (EU) 2017/746, Regulation (EU) 2017/745, ISO 15197, ISO 13485, IEC 60601-2-47, ANSI/AAMI EC57, ISO 10993-1, ISO 14971.

Assigned technical tutor:every module ends with a deliverable that your tutor marks individually.
Standards-based learning:guided reading of Regulation (EU) 2017/746, Regulation (EU) 2017/745 and ISO 15197 applied to real cases, not as a theoretical annex.
Industry software:MATLAB, Python with SciPy and NeuroKit2, EEGLAB, LabVIEW and COMSOL Multiphysics, in free, academic or evaluation versions.
Master's Thesis with defence:A biosensor and signal-processing prototype, from clinical need to regulatory fit, defended before a panel.
Flexible format:100% online, no fixed timetables, compatible with full-time work.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Clinical need and biomarker
Define the clinical need and the target biomarker for the device.
Sensor characterisation
Select the transduction principle and characterise the sensor analytically in the laboratory.
Signal processing chain
Build the acquisition and filtering chain for the sensor's biosignals.
Interpretation algorithm
Develop and validate the algorithm against annotated data or volunteer samples.
Master's Thesis
A complete biosensor prototype with its regulatory and quality fit, defended before a panel.
Career opportunities

Where this takes you

Biosensor engineerBiomedical signal processing engineerIn vitro diagnostics researcherClinical algorithm developerIVD regulatory affairs specialistBiomedical hardware engineer
Admissions & scholarships

Requirements

  • University degree in engineering, science or architecture, or equivalent demonstrable professional experience.
  • Internet connection and a computer capable of running the programme software.
  • English sufficient to read technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.

You work with MATLAB, Python with SciPy and NeuroKit2, EEGLAB, LabVIEW and COMSOL Multiphysics, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.

A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.

A university degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the programme software and English sufficient to read technical standards.

Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.

Master’s in Biosensors and Biosignal Processing EngineeringEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.