Postgraduate DiplomaCivil, Rail & Smart Cities Applications open

Diploma in Design of Cable-Stayed and Extradosed Bridges

Online postgraduate diploma of 800 hours in cable-stayed and extradosed bridge design, structured in 8 modules covering bridge typologies, stay cables and anchorage systems, structural analysis, deck design, pylons and foundations, construction process and aerodynamics under the Eurocodes, with an assigned technical tutor.

Duration800 hours · 6–8 months
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Select the appropriate stay arrangement for each site.

02

Size stay cables and anchorages for strength and fatigue.

03

Model cable-stayed bridges taking non-linearities into account.

04

Design decks and pylons in accordance with the Eurocodes.

05

Analyse the construction process and the stressing sequence.

06

Assess the aerodynamic and dynamic response of the bridge.

07

Develop a complete preliminary design for a cable-stayed or extradosed bridge.

Profile

Who it's for

  • Bridge engineers.
  • Structural analysts and designers.
  • Bridge construction engineers.
  • Designers of landmark structures.
  • Post-tensioning and stressing control engineers.
  • Structural consultants.
  • Engineering or science graduates looking to move into road infrastructure.
Standards & tools

What you'll work with

  • EN 1992-2 (Eurocode 2 — concrete bridges)
  • EN 1993-1-11 (Eurocode 3 — design of structures with tension components)
  • EN 1994-2 (Eurocode 4 — composite steel and concrete bridges)
  • EN 1991-2 (Eurocode 1 — traffic loads on bridges)
  • EN 1991-1-4 (Eurocode 1 — wind actions)
  • IAP-11 (Spanish code on actions for road bridges)
  • fib Bulletin 89 (acceptance of stay cable systems using prestressing steels)
  • PTI DC45.1 (recommendations for stay cable design, testing and installation)
  • Midas Civil
  • SOFiSTiK
  • CSI SAP2000
  • Allplan Bridge
  • LUSAS Bridge
Syllabus

8 modules

  1. 1.1History and evolution of cable-stayed bridges
  2. 1.2Harp and fan stay arrangements
  3. 1.3Pylon shapes and materials
  4. 1.4Concrete, composite and steel decks
  5. 1.5Central and lateral suspension
  6. 1.6Span ranges and proportions
  7. 1.7The extradosed bridge concept
  8. 1.8Landmark reference bridges
  9. 1.9Typology selection criteria
  10. 1.10Workshop: preliminary design of a 300 m cable-stayed bridge
  1. 2.1Parallel strands and locked-coil cables
  2. 2.2Corrosion protection of stay cables
  3. 2.3Active and passive anchorages
  4. 2.4Saddles in extradosed bridges
  5. 2.5Fatigue of stay cables
  6. 2.6fib and PTI recommendations for stay cables
  7. 2.7Stay cable qualification tests
  8. 2.8Stay cable dampers
  9. 2.9Replacing stay cables in service
  10. 2.10Practical exercise: fatigue check of a stay cable
  1. 3.1Frame models and non-linearity
  2. 3.2Ernst equivalent modulus
  3. 3.3Second-order effects in pylons
  4. 3.4Concrete creep and shrinkage
  5. 3.5Optimisation of stressing forces
  6. 3.6Traffic loads according to EN 1991-2
  7. 3.7Thermal actions on deck and stay cables
  8. 3.8Seismic analysis of the whole structure
  9. 3.9Accidental loss of a stay cable
  10. 3.10Lab: cable-stayed bridge model in Midas Civil
  1. 4.1Box, slab and edge-girder sections
  2. 4.2Steel-concrete composite decks
  3. 4.3Transverse load distribution
  4. 4.4Longitudinal prestressing of the deck
  5. 4.5Stay cable anchorages in the deck
  6. 4.6Torsional stiffness of the deck
  7. 4.7Checks according to EN 1992-2 and EN 1994-2
  8. 4.8Deck construction details
  9. 4.9Expansion joints and bearings
  10. 4.10Case study: deck design of an extradosed bridge
  1. 5.1H, A and inverted-Y pylons
  2. 5.2Stay cable anchorage in the pylon
  3. 5.3Buckling and stability of the pylon
  4. 5.4High-strength concrete
  5. 5.5Deep foundations of pylons
  6. 5.6Soil-structure interaction in foundations
  7. 5.7Protection against ship impact
  8. 5.8Seismic design of pylons
  9. 5.9Construction with climbing formwork
  10. 5.10Practical exercise: stability of a pylon
  1. 6.1Balanced cantilever construction
  2. 6.2Stay cable stressing sequence
  3. 6.3Construction stage analysis
  4. 6.4Geometric control during construction
  5. 6.5Stay cable force adjustment
  6. 6.6Form travellers
  7. 6.7Closure at midspan
  8. 6.8Risks during construction
  9. 6.9Monitoring during execution
  10. 6.10Case study: simulation of construction stages
  1. 7.1Wind effects on decks
  2. 7.2Flutter and galloping
  3. 7.3Vortex shedding
  4. 7.4Rain-wind induced stay cable vibrations
  5. 7.5Wind tunnel testing
  6. 7.6Structural damping of the whole bridge
  7. 7.7User comfort
  8. 7.8Bridge load testing
  9. 7.9Inspection and maintenance
  10. 7.10Lab: modal analysis of a cable-stayed bridge
  1. 8.1Site constraints
  2. 8.2Study of alternatives
  3. 8.3Preliminary design of the solution
  4. 8.4Analysis model
  5. 8.5Stay cable design
  6. 8.6Proposed construction process
  7. 8.7Structural checks at serviceability and ultimate limit states
  8. 8.8Drawings and budget
  9. 8.9Report and presentation
  10. 8.10Final project: final review with the tutor
Methodology, software & labs

How you'll learn

Training is 100% online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within the intake, so it can be combined with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Midas Civil, SOFiSTiK, CSI SAP2000, Allplan Bridge and LUSAS Bridge, in free, academic or evaluation versions. Practical work is based on real procedures: construction stage models of cable-stayed bridges, fatigue checks of stay cables and studies of typology alternatives. Assessment is continuous by module, plus the final project.

Standards covered: EN 1992-2, EN 1993-1-11, EN 1994-2, EN 1991-2, EN 1991-1-4, IAP-11, fib Bulletin 89, PTI DC45.1

Assigned technical tutor:every module ends with a deliverable that your tutor marks individually.
Standards-based learning:guided reading of EN 1992-2, EN 1993-1-11 and EN 1994-2 applied to real cases, not as a theoretical annex.
Industry software:Midas Civil, SOFiSTiK, CSI SAP2000, Allplan Bridge and LUSAS Bridge, in free, academic or evaluation versions.
Final project:a preliminary design of a cable-stayed bridge, from site constraints and alternatives to stay cable design, construction process, drawings and budget, reviewed by your tutor.
Flexible format:100% online, no fixed timetables, compatible with full-time work.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Site and alternatives
Analyse the site constraints and compare bridge alternatives.
Preliminary sizing
Pre-size the chosen solution and build the analysis model.
Stay cable design
Design the stay cables and check them for fatigue.
Construction and checks
Define the construction process and run SLS and ULS checks.
Final project
Deliver drawings, budget and report for review by your tutor.
Career opportunities

Where this takes you

Bridge EngineerStructural AnalystBridge Construction EngineerLandmark Structures DesignerStressing Control EngineerStructural Consultant
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • An internet connection and a computer capable of running the programme software.
  • English sufficient to read technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours over 6–8 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.

You work with Midas Civil, SOFiSTiK, CSI SAP2000, Allplan Bridge and LUSAS Bridge, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.

A SEIUM Institute diploma, awarded on passing the continuous assessment and the final project. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.

Yes. Modules passed are recognised in a higher programme in the same area (postgraduate diploma or master's). Ask about the recognition policy when you enrol.

Prior technical training or professional experience in the sector (no university degree required), a computer able to run the software and English sufficient to read technical standards.

Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.

Diploma in Design of Cable-Stayed and Extradosed BridgesEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.