Postgraduate DiplomaEnergy and Networks Applications open

Postgraduate Diploma in Power Quality and Monitoring Audits

800-hour online Postgraduate Diploma in Power Quality and Monitoring Audits. 8 modules covering IEC 61000-4-30 (power quality measurement methods), EN 50160 (characteristics of the supply voltage) and Fluke Energy Analyze Plus. Assigned tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Interpret the applicable power quality standards.

02

Select Class A measuring instrumentation.

03

Plan measurement and audit campaigns.

04

Analyse data on harmonics, flicker and voltage dips.

05

Diagnose the origin of power quality problems.

06

Design permanent monitoring systems.

07

Write reports with justified technical recommendations.

Profile

Who it's for

  • Power quality auditor looking to specialise in Power Quality and Monitoring Audits.
  • Electrical measurement technician looking to specialise in Power Quality and Monitoring Audits.
  • Electrical maintenance engineer looking to specialise in Power Quality and Monitoring Audits.
  • Electrical efficiency consultant looking to specialise in Power Quality and Monitoring Audits.
  • Grid monitoring engineer looking to specialise in Power Quality and Monitoring Audits.
  • Electrical data analyst looking to specialise in Power Quality and Monitoring Audits.
  • Engineering or science graduates seeking to enter industry.
Standards & tools

What you'll work with

  • IEC 61000-4-30 (power quality measurement methods)
  • EN 50160 (characteristics of the supply voltage)
  • IEC 61000-4-7 (harmonic measurement)
  • IEC 61000-4-15 (flickermeter)
  • IEEE 1159 (quality monitoring)
  • IEEE 519-2022 (harmonic limits)
Syllabus

8 modules · 800 h

  1. 1.1Voltage quality parameters
  2. 1.2EN 50160 standard on voltage characteristics
  3. 1.3IEC 61000-4-30 standards on measurement methods
  4. 1.4Instrument classes A and S
  5. 1.510-minute measurement aggregation
  6. 1.6Supply continuity indicators
  7. 1.7Quality regulation in distribution
  8. 1.8Responsibility between grid and user
  9. 1.9Contracts with quality guarantees
  10. 1.10Case study: interpreting an EN 50160 report
  1. 2.1Portable network analysers
  2. 2.2Fixed analysers and permanent monitoring
  3. 2.3Measurement transformers and their accuracy
  4. 2.4Clamp meters and Rogowski coils
  5. 2.5Bandwidth and sampling frequency
  6. 2.6Transient capture and waveforms
  7. 2.7Time synchronisation
  8. 2.8Calibration and traceability
  9. 2.9Safe connection in CAT III and IV environments
  10. 2.10Practical: configuring a Class A analyser
  1. 3.1Audit objectives and scope
  2. 3.2Gathering prior information
  3. 3.3Selecting measurement points
  4. 3.4Minimum duration of campaigns
  5. 3.5Setting thresholds and triggers
  6. 3.6Coordination with maintenance and production
  7. 3.7Risks and work permits
  8. 3.8Documentation and field records
  9. 3.9Standard audit plan
  10. 3.10Workshop: audit plan for an industrial plant
  1. 4.1Voltage and current trends
  2. 4.2Harmonic spectrum and THD
  3. 4.3K-factor and crest factor
  4. 4.4Flicker analysis: Pst and Plt
  5. 4.5Events and tolerance curves
  6. 4.6Correlation with production processes
  7. 4.7Manufacturers' analysis software
  8. 4.8Python analysis of data exports
  9. 4.9Identifying the disturbance source
  10. 4.10Laboratory: analysing a one-week measurement campaign
  1. 5.1Overheating of neutrals and transformers
  2. 5.2Unwanted protection tripping
  3. 5.3Drive and electronics failures
  4. 5.4Resonances with capacitor banks
  5. 5.5Earthing and noise problems
  6. 5.6Electromagnetic interference
  7. 5.7Origin of dips: internal or external network
  8. 5.8Problems in data centres
  9. 5.9Problems in installations with renewables
  10. 5.10Case study: diagnosing stoppages on a production line
  1. 6.1Architecture of monitoring systems
  2. 6.2Selecting fixed monitoring points
  3. 6.3EPMS and SCADA platforms
  4. 6.4IEC 61850 and Modbus protocols
  5. 6.5Automatic alarms and reports
  6. 6.6Quality indicators for management
  7. 6.7Integration with ISO 50001 energy management
  8. 6.8Cyber security in measurement systems
  9. 6.9Maintenance of the measurement system
  10. 6.10Practical: designing a monitoring system for a hospital
  1. 7.1Structure of an audit report
  2. 7.2Graphical presentation of results
  3. 7.3Compliance with reference standards
  4. 7.4Prioritising corrective measures
  5. 7.5Estimating costs and savings
  6. 7.6Communication with the distribution company
  7. 7.7Supply quality complaints
  8. 7.8Follow-up of implemented measures
  9. 7.9Auditor ethics and confidentiality
  10. 7.10Case study: audit report for a food industry plant
  1. 8.1Definition of the installation and objectives
  2. 8.2Measurement plan
  3. 8.3Measurement campaign or data analysis
  4. 8.4Analysis of quality parameters
  5. 8.5Diagnosis of causes
  6. 8.6Proposal of corrective measures
  7. 8.7Design of permanent monitoring
  8. 8.8Final audit report
  9. 8.9Dissertation and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

100 % online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: students progress at their own pace within the intake, which makes it compatible with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Fluke Energy Analyze Plus, PQView, Python (pandas), advanced Excel, in free, academic or evaluation versions. Tests are studied using real measurement campaign procedures with Class A analysers, diagnosis of industrial installations and writing of audit reports. Assessment is continuous by module, plus the final integrating project.

Accreditable laboratories(EN ISO/IEC 17025) with rotor test rig, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-oriented final project:safety case, test plan, compliance dossier and operating limits.
Industry mentoring:instructors with a track record in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, with OT cyber security, DIH and compliance as its pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Definition of the installation and objectives

Interpret the applicable power quality standards.

Measurement plan

Select Class A measuring instrumentation.

Measurement campaign or data analysis

Plan measurement and audit campaigns.

Analysis of quality parameters

Analyse data on harmonics, flicker and voltage dips.

Diagnosis of causes

Diagnose the origin of power quality problems.

Career opportunities

Where this takes you

Power quality auditorElectrical measurement technicianElectrical maintenance engineerElectrical efficiency consultantGrid monitoring engineerElectrical data analyst
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient Spanish to follow technical standards documentation.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme comprises 800 total hours spread over 6 to 8 months. This is an average of 10 to 15 hours per week, compatible with a full-time job.

You will work with Fluke Energy Analyze Plus, PQView, Python (pandas), advanced Excel. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM own diploma upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are credited towards the advanced programme. Check the credit recognition policy when enrolling.

Postgraduate Diploma in Power Quality and Monitoring AuditsEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.