Postgraduate Diploma in Use Error Management and Mitigations

Online 800-hour Postgraduate Diploma in Use Error Management and Mitigations. 8 modules covering IEC 62366-1 (usability engineering), ISO 14971 (risk management for medical devices) and Jama Connect. Dedicated tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Classify the types of use error in medical devices.

02

Identify use-related hazards through task analysis.

03

Estimate and evaluate use-related risk.

04

Apply the hierarchy of risk control measures.

05

Design interfaces that prevent use errors.

06

Verify the effectiveness of implemented mitigations.

07

Analyse post-market data to detect new use errors.

Profile

Who it's for

  • Use risk engineer looking to specialise in Use Error Management and Mitigations.
  • Human factors specialist looking to specialise in Use Error Management and Mitigations.
  • Medical device interface designer looking to specialise in Use Error Management and Mitigations.
  • Quality and regulatory engineer looking to specialise in Use Error Management and Mitigations.
  • Post-market surveillance manager looking to specialise in Use Error Management and Mitigations.
  • Patient safety consultant looking to specialise in Use Error Management and Mitigations.
  • Graduates in engineering or sciences seeking to join medical device manufacturers.
Standards & tools

What you'll work with

  • IEC 62366-1 (usability engineering)
  • ISO 14971 (risk management for medical devices)
  • ISO/TR 24971 (application guide for ISO 14971)
  • ANSI/AAMI HE75
  • IEC 60601-1-6
  • Regulation (EU) 2017/745 (medical devices)
  • 21 CFR Part 820 (FDA quality system)
Syllabus

8 modules · 800 h

  1. 1.1Definition of use error in IEC 62366-1
  2. 1.2Abnormal use versus use error
  3. 1.3Human error taxonomies
  4. 1.4Perception, cognition and action errors
  5. 1.5Design contribution to error
  6. 1.6Recalls due to use errors
  7. 1.7MAUDE databases and safety alerts
  8. 1.8Clinical and economic impact
  9. 1.9Patient safety culture
  10. 1.10Practical case: analysis of infusion pump alerts
  1. 2.1Task analysis for error identification
  2. 2.2PCA: perception, cognition and action
  3. 2.3Use failure mode analysis (uFMEA)
  4. 2.4Analysis of reasonably foreseeable misuse
  5. 2.5Review of complaints and post-market data
  6. 2.6Analysis of similar products
  7. 2.7Hazardous use scenarios
  8. 2.8Alarm interfaces and associated risks
  9. 2.9Errors in labelling and instructions
  10. 2.10Practice: uFMEA of a home pulse oximeter
  1. 3.1Severity of consequences
  2. 3.2Probability of use errors
  3. 3.3Use-related risk analysis (URRA)
  4. 3.4Determination of critical tasks
  5. 3.5Integration with ISO 14971
  6. 3.6Fault trees with human error
  7. 3.7Human reliability: THERP and HEART
  8. 3.8Acceptability of use risk
  9. 3.9Documentation of the evaluation
  10. 3.10Workshop: URRA of an auto-injector
  1. 4.1Inherently safe design
  2. 4.2Protective measures in the device
  3. 4.3Information for safety
  4. 4.4Training as a control measure
  5. 4.5Locking and confirmation functions
  6. 4.6Alarm and warning design
  7. 4.7Connector design and prevention of incorrect connections
  8. 4.8ISO 80369 connector standards
  9. 4.9Relative effectiveness of measures
  10. 4.10Practical case: mitigations for incorrect connections
  1. 5.1Affordances and physical constraints
  2. 5.2Mapping and feedback
  3. 5.3Screen and menu design
  4. 5.4Units of measurement and numerical formats
  5. 5.5Colour and shape coding
  6. 5.6Packaging and labelling design
  7. 5.7Effective instructions for use
  8. 5.8Interfaces for high-workload environments
  9. 5.9IEC 60601-1-6 and IEC 60601-1-8 standards
  10. 5.10Laboratory: redesign of an infusion pump screen
  1. 6.1Verification of implementation
  2. 6.2Validation of effectiveness with users
  3. 6.3Targeted training studies
  4. 6.4Root cause analysis following validation
  5. 6.5Iteration and new mitigations
  6. 6.6Residual use risk
  7. 6.7Benefit-risk analysis
  8. 6.8Mitigation-test traceability
  9. 6.9Communication to the notified body
  10. 6.10Practice: mitigation traceability matrix
  1. 7.1Collection of real-world use data
  2. 7.2Analysis of use error trends
  3. 7.3Incident reporting and FSCA
  4. 7.4Feedback from clinical users
  5. 7.5Updating the usability file
  6. 7.6Design changes after commercialisation
  7. 7.7Training and safety communications
  8. 7.8Use safety indicators
  9. 7.9Coordination with risk management
  10. 7.10Workshop: analysis of complaint trends
  1. 8.1Device selection
  2. 8.2Task analysis
  3. 8.3Identification of use errors
  4. 8.4Risk evaluation
  5. 8.5Design of mitigations
  6. 8.6Verification and validation plan
  7. 8.7Surveillance plan
  8. 8.8Error management report
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

Fully online training on the SEIUM campus, with downloadable material, recorded classes and a dedicated technical tutor. There are no fixed timetables: students progress at their own pace within the intake, allowing them to combine the programme with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Jama Connect, Greenlight Guru, advanced Excel, Figma, in free, academic or evaluation versions. Tests are studied using real procedures for critical task analysis, use failure mode analysis (uFMEA) and review of post-market surveillance reports. Assessment is continuous, module by module, plus the final integrative project.

Accreditable laboratories(EN ISO/IEC 17025) with a rotor test bench, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-oriented Master's Thesis (final project):safety case, test plan, compliance dossier and operational limits.
Industry mentorship:lecturers with experience in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, OT cybersecurity, DIH and compliance as its pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Device selection

Classify the types of use error in medical devices.

Task analysis

Identify use-related hazards through task analysis.

Identification of use errors

Estimate and evaluate use-related risk.

Risk evaluation

Apply the hierarchy of risk control measures.

Design of mitigations

Design interfaces that prevent use errors.

Career opportunities

Where this takes you

Use risk engineerHuman factors specialistMedical device interface designerQuality and regulatory engineerPost-market surveillance managerPatient safety consultant
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient level of Spanish to follow the reading of technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme comprises 800 total hours spread over 6 to 8 months. That is between 10 and 15 hours per week on average, compatible with a full-time job.

You work with Jama Connect, Greenlight Guru, advanced Excel and Figma. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM diploma upon passing the continuous assessment and the integrative project. It is in-house training, not an official Ministry qualification.

Yes. Modules passed in a course or diploma in the same area are credited towards the advanced programme. Check the credit transfer policy when you enrol.

Postgraduate Diploma in Use Error Management and MitigationsEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.