Postgraduate DiplomaAutonomous, ADAS & Software-Defined Vehicle Applications open

Postgraduate Diploma in SOTIF+Functional Integration with Safety Cases

Online 800-hour Postgraduate Diploma in SOTIF+Functional Integration with Safety Cases. 8 modules with ISO 26262:2018, ISO 21448:2022 and Ansys medini analyze. Assigned tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Integrate the ISO 26262 and ISO 21448 lifecycles into a single plan.

02

Carry out joint and coherent hazard analyses.

03

Define architectures and requirements that cover faults and insufficiencies.

04

Plan combined verifications with reusable evidence.

05

Build safety cases using GSN notation.

06

Integrate functional safety, SOTIF and cybersecurity branches.

07

Prepare dossiers for independent assessment and type approval.

Profile

Who it's for

  • Functional safety engineer who wants to specialise in SOTIF+Functional Integration with Safety Cases.
  • SOTIF engineer who wants to specialise in SOTIF+Functional Integration with Safety Cases.
  • Safety case lead who wants to specialise in SOTIF+Functional Integration with Safety Cases.
  • Safety assessor who wants to specialise in SOTIF+Functional Integration with Safety Cases.
  • ADAS systems architect who wants to specialise in SOTIF+Functional Integration with Safety Cases.
  • Homologation consultant who wants to specialise in SOTIF+Functional Integration with Safety Cases.
  • Graduates in engineering or science seeking to join automotive manufacturers.
Standards & tools

What you'll work with

  • ISO 26262:2018
  • ISO 21448:2022
  • UL 4600
  • ISO/TS 5083:2025
  • GSN Community Standard v3
  • ISO/IEC/IEEE 15026-2
  • ISO/SAE 21434:2021
  • Reglamento (UE) 2022/1426
Syllabus

8 modules · 800 h

  1. 1.1Systematic and random faults and insufficiencies
  2. 1.2ISO 26262 lifecycle
  3. 1.3ISO 21448 iterative cycle
  4. 1.4Interface points between both standards
  5. 1.5Item, function and element out of context
  6. 1.6Integrated safety plan
  7. 1.7Management of joint confirmation
  8. 1.8Roles and competences of the safety team
  9. 1.9Common errors in integrated projects
  10. 1.10Case study: map of shared work products
  1. 2.1HARA and SOTIF analysis in parallel
  2. 2.2Hazards from malfunction and from limitation
  3. 2.3Unified severity classification
  4. 2.4Common operating scenarios
  5. 2.5Foreseeable misuse in both analyses
  6. 2.6Safety goals and acceptance criteria
  7. 2.7Consolidation of safety measures
  8. 2.8Tools for hazard management
  9. 2.9Review and approval of the analysis
  10. 2.10Workshop: joint analysis of an urban AEB
  1. 3.1Functional safety concept
  2. 3.2Technical and performance requirements
  3. 3.3Redundancy, diversity and controlled degradation
  4. 3.4Plausibility monitors
  5. 3.5Allocation to hardware and software
  6. 3.6Management of perception uncertainty
  7. 3.7Doer-checker architectures
  8. 3.8Driver interfaces and alerts
  9. 3.9Bidirectional requirements traceability
  10. 3.10Practice: safety architecture of a lane keeping system
  1. 4.1Layered verification strategy
  2. 4.2Fault injection tests
  3. 4.3Scenario-based tests
  4. 4.4Coverage of requirements and scenarios
  5. 4.5FMEA and FTA of the system
  6. 4.6Common cause analysis
  7. 4.7Regression tests after changes
  8. 4.8Reusable verification evidence
  9. 4.9Management of non-conformities
  10. 4.10Laboratory: fault injection campaign on HIL
  1. 5.1Concept of a safety case
  2. 5.2Claims, arguments and evidence
  3. 5.3Common argumentation structures
  4. 5.4GSN notation: goals, strategies and solutions
  5. 5.5Context, assumptions and justifications
  6. 5.6Reusable argument patterns
  7. 5.7Modular arguments and contracts
  8. 5.8Confidence in evidence
  9. 5.9Argument editing tools
  10. 5.10Workshop: top-level GSN argument
  1. 6.1Functional safety branch
  2. 6.2SOTIF branch and residual risk
  3. 6.3Safety-relevant cybersecurity branch
  4. 6.4Process and competence argument
  5. 6.5Integration with UL 4600
  6. 6.6Management of defeaters and counterarguments
  7. 6.7Safety performance indicators
  8. 6.8Maintaining the case during operation
  9. 6.9Preparation for external audit
  10. 6.10Case study: safety case of a robotaxi
  1. 7.1Functional safety assessment
  2. 7.2Process audit and confirmations
  3. 7.3Independent assessment under UL 4600
  4. 7.4Requirements of Regulation (EU) 2022/1426
  5. 7.5Technical file for the authority
  6. 7.6Interaction with technical services
  7. 7.7Management of findings and corrective actions
  8. 7.8Supplier management and DIA
  9. 7.9Liability and legal documentation
  10. 7.10Practice: mock audit of a safety case
  1. 8.1Definition of the item and its ODD
  2. 8.2Joint hazard analysis
  3. 8.3Safety concept
  4. 8.4Combined verification plan
  5. 8.5Complete GSN argument
  6. 8.6Confidence assessment
  7. 8.7Case maintenance plan
  8. 8.8Assessment report
  9. 8.9Dissertation and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

Fully 100 % online training on the SEIUM campus, with downloadable material, recorded classes and assigned technical tutor. No fixed timetables: students progress at their own pace within the intake, which makes it possible to combine with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Ansys medini analyze, Astah System Safety, Adelard ASCE, IBM DOORS Next, Vector PREEvision, in free, academic or evaluation versions. Tests are studied using real fault injection procedures on HIL benches, scenario-based verification in simulation and safety case audits. Assessment is continuous per module plus the final integrating project.

Accreditable laboratories(EN ISO/IEC 17025) with rotor bench, EMC/Lightning pre-compliance, HIL/SIL, vibrations/acoustics.
Evidence-oriented Master's Thesis:safety case, test plan, compliance dossier and operational limits.
Industry Mentored:teachers with experience in training, , eVTOL/UAM and flight test.
Flexible modality(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:safety-by-design approach, cyber-OT, DIH and compliance as pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Definition of the item and its ODD

Integrate the ISO 26262 and ISO 21448 lifecycles into a single plan.

Joint hazard analysis

Carry out joint and coherent hazard analyses.

Safety concept

Define architectures and requirements that cover faults and insufficiencies.

Combined verification plan

Plan combined verifications with reusable evidence.

Complete GSN argument

Build safety cases using GSN notation.

Career opportunities

Where this takes you

Functional safety engineerSOTIF engineerSafety case leadSafety assessorADAS systems architectHomologation consultant
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. No university degree is required.
  • Internet connection and a computer capable of running the programme software.
  • Sufficient level of Spanish to follow the reading of technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme consists of 800 total hours spread over 6 to 8 months. That is between 10 and 15 hours per week on average, compatible with a full-time job.

You work with Ansys medini analyze, Astah System Safety, Adelard ASCE, IBM DOORS Next, Vector PREEvision. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

An own diploma from SEIUM upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are credited towards the advanced programme. Check the credit transfer policy when you enrol.

Postgraduate Diploma in SOTIF+Functional Integration with Safety CasesEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.