Postgraduate Diploma in Safety and NFPA/UL Standards for BESS
Online Postgraduate Diploma of 800 hours in safety and NFPA/UL standards for BESS. 8 modules covering NFPA 855 (installation of stationary energy storage systems), UL 9540 (energy storage systems) and FDS (Fire Dynamics Simulator). Assigned tutor and open enrolment.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Explain the thermal runaway mechanisms in lithium-ion batteries.
Interpret the requirements of UL 9540 and the results of UL 9540A.
Apply the requirements of NFPA 855 to the design of an installation.
Design measures for detection, suppression and explosion venting.
Integrate the electrical and functional safety of the BESS system.
Relate the US regulatory framework to the European and Spanish frameworks.
Prepare safe operation plans and emergency response procedures.
Who it's for
- BESS safety engineer who wants to specialise in Safety and NFPA/UL Standards for BESS.
- Fire protection specialist who wants to specialise in Safety and NFPA/UL Standards for BESS.
- Energy storage engineer who wants to specialise in Safety and NFPA/UL Standards for BESS.
- Industrial risk prevention technician who wants to specialise in Safety and NFPA/UL Standards for BESS.
- Regulatory compliance consultant who wants to specialise in Safety and NFPA/UL Standards for BESS.
- Battery plant operations manager who wants to specialise in Safety and NFPA/UL Standards for BESS.
- Graduates in engineering or sciences seeking to enter energy storage.
What you'll work with
- NFPA 855 (installation of stationary energy storage systems)
- UL 9540 (energy storage systems)
- UL 9540A (test method for thermal propagation)
- UL 1973 (batteries for stationary applications)
- IEC 62933-5-2 (safety of electrochemical energy storage systems)
- IEC 62619 (safety of industrial lithium batteries)
- NFPA 68 (explosion protection by deflagration venting)
8 modules · 800 h
1.1Components of a BESS1.2LFP, NMC and other chemistries1.3Cell and module formats1.4Battery management system (BMS)1.5Thermal runaway and propagation1.6Venting gases and deflagration risk1.7McMicken incident and other cases1.8Electrical and chemical hazards1.9Life cycle and degradation1.10Case study: analysis of the McMicken incident
2.1Scope of UL 9540 for systems2.2UL 1973 component certification2.3Inverters and UL 17412.4UL 9540A test methodology2.5Tests at cell, module, unit and installation level2.6Interpreting gas results2.7Propagation criteria2.8Limitations of testing2.9Using the test for design2.10Workshop: reading a UL 9540A report
3.1Scope and structure of NFPA 8553.2Energy thresholds and applicability3.3Separation and distances3.4Capacity limits per group3.5Indoor and outdoor location3.6Container requirements3.7HMA risk assessment3.8Emergency response plan3.9Relationship with IFC and NFPA 13.10Practice: verifying a layout against NFPA 855
4.1Early gas detection4.2Smoke and heat detection4.3Suppression systems: water, aerosol and clean agents4.4Explosion venting according to NFPA 684.5Explosion prevention according to NFPA 694.6Design of relief panels4.7CFD modelling of gas dispersion4.8Water for cooling and containment4.9Management of contaminated water4.10Laboratory: sizing explosion ventilation
5.1DC overcurrent protection5.2Isolation and disconnection5.3Electric arc in batteries5.4Functional safety of the BMS5.5IEC 62619 and IEC 62933-5-25.6IEC 61508 applied to control5.7Emergency stops and interlocks5.8System earthing5.9BMS and EMS cybersecurity5.10Case study: HAZOP analysis of a container
6.1Regulation (EU) 2023/1542 on batteries6.2Low Voltage and EMC Directives6.3ATEX Directive and its applicability6.4Spanish fire safety regulation RSCIEI6.5Technical building code and municipal licences6.6FM Global insurer requirements6.7FM Global DS 5-336.8Transport of batteries under ADR and UN 38.36.9End-of-life management and recycling6.10Workshop: regulatory compliance matrix
7.1Safe operation plan7.2Maintenance and condition monitoring7.3BMS alarms and response7.4Coordination with fire services7.5Procedures after thermal runaway7.6Management of damaged batteries7.7Re-ignition and post-event monitoring7.8Staff training7.9Incident investigation7.10Case study: emergency drill in a BESS
8.1System and site description8.2Hazard identification8.3NFPA 855 and UL 9540 compliance analysis8.4Fire protection design8.5Ventilation and detection design8.6Emergency response plan8.7Residual risk analysis8.8Documentation for authorities8.9Report and presentation8.10Final review with the tutor
How you'll learn
100 % online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: students progress at their own pace within the intake, which makes it compatible with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is FDS (Fire Dynamics Simulator), DNV Phast, ETAP, MATLAB, in free, academic or evaluation versions. Tests are studied using real procedures for interpreting UL 9540A test results at cell, module and unit level, gas dispersion and deflagration modelling, and HAZID and HAZOP risk analysis of BESS installations. Assessment is continuous per module plus the final integrative project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Explain the thermal runaway mechanisms in lithium-ion batteries.
Interpret the requirements of UL 9540 and the results of UL 9540A.
Apply the requirements of NFPA 855 to the design of an installation.
Design measures for detection, suppression and explosion venting.
Integrate the electrical and functional safety of the BESS system.
Where this takes you
Requirements
- Prior technical training or professional experience in the sector. No university degree is required.
- Internet connection and a computer capable of running the programme's software.
- Sufficient Spanish to follow technical standards documents.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme comprises 800 hours in total, spread over 6 to 8 months. That is an average of 10 to 15 hours per week, compatible with full-time work.
You will work with FDS (Fire Dynamics Simulator), DNV Phast, ETAP, MATLAB. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.
A diploma issued by SEIUM upon passing continuous assessment and the final integrative project. It is in-house training, not an official qualification from the Ministry.
Yes. Modules passed in a course or postgraduate diploma in the same area can be credited towards the higher programme. Check the credit transfer policy when you enrol.
Related programmes
Postgraduate Diploma in Local Markets and Island Business Models
Online 800-hour Postgraduate Diploma in Local Markets and Island Business Models. 8 modules covering Royal Decree 738/2015 (non-peninsular electricity systems), Directive (EU) 2019/944 (internal electricity market)…
Postgraduate Diploma in Applied Dispatch Optimisation and Unit Commitment
Online 800-hour Postgraduate Diploma in Applied Dispatch Optimisation and Unit Commitment. 8 modules covering Regulation (EU) 2017/1485 (system operation guideline), Regulation (EU) 2015/1222 (capacity allocation and…
Postgraduate Diploma in Futures, Options and Hedging Strategies
Online 800 h Postgraduate Diploma in Futures, Options and Hedging Strategies. 8 modules covering Directive 2014/65/EU (MiFID II), Regulation (EU) 648/2012 (EMIR) and Python (NumPy, pandas).…
More in Energy and Networks
All Energy and Networks programmes → · How to apply · Fees & financing · Scholarships