Postgraduate Diploma in Quick Tool Change and IO-Link Connectivity
Online 800-hour Postgraduate Diploma in Quick Tool Change and IO-Link Connectivity. 8 modules covering IEC 61131-9:2022 (IO-Link), ISO 9409-1:2004 and Siemens TIA Portal. Assigned tutor and open enrolment.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Select tool changers according to the application.
Integrate pneumatic, electrical and signal utilities.
Configure IO-Link networks and their devices.
Automate parameterisation after the tool change.
Programme change sequences with PLC and robot.
Exploit tool diagnostic data.
Improve cell flexibility and OEE.
Who it's for
- Automation engineer who wants to specialise in Quick Tool Change and IO-Link Connectivity.
- Robotics integrator who wants to specialise in Quick Tool Change and IO-Link Connectivity.
- Sensor and communications technician who wants to specialise in Quick Tool Change and IO-Link Connectivity.
- Maintenance engineer who wants to specialise in Quick Tool Change and IO-Link Connectivity.
- PLC programmer who wants to specialise in Quick Tool Change and IO-Link Connectivity.
- Flexible process engineer who wants to specialise in Quick Tool Change and IO-Link Connectivity.
- Graduates in engineering or science who want to enter the automotive sector.
What you'll work with
- IEC 61131-9:2022 (IO-Link)
- ISO 9409-1:2004
- IEC 61158 (fieldbuses)
- ISO 10218-2:2025
- IEC 62541 (OPC UA)
8 modules · 800 h
1.1Need for tool change in robotics1.2Manual and automatic tool changers1.3Pneumatic and electrical locking mechanisms1.4Repeatability and load capacity1.5Utility passage: air, signal and power1.6Tool storage stations1.7ISO 9409-1 interfaces and flanges1.8Safety during loss of energy1.9Selecting a tool changer by application1.10Workshop: selecting a changer for three tools
2.1Pneumatic and vacuum modules2.2Electrical and signal modules2.3Power and servo transmission2.4Fluid and coolant passage2.5Cable and hose management2.6Design of storage rack supports2.7Detection of tool presence2.8Tool identification2.9Contact wear and maintenance2.10Practice: integrating modules into a tool changer
3.1IO-Link master–device architecture3.2Point-to-point communication3.3SIO and COM modes3.4COM1, COM2 and COM3 speeds3.5Process, service and event data3.6IODD files and device description3.7Class A and class B ports3.8Standard M12 cabling3.9IO-Link versus conventional I/O3.10Laboratory: configuring an IO-Link master
4.1IO-Link sensors and actuators4.2IO-Link electric grippers4.3IO-Link vacuum generators4.4Data storage and device replacement4.5Automatic parameterisation after the change4.6IO-Link Wireless for tools4.7Hubs and valve modules4.8Device diagnostics4.9Smart sensor profiles4.10Practice: automatic parameterisation of a gripper
5.1IO-Link masters over PROFINET5.2Masters over EtherNet/IP and EtherCAT5.3Function blocks in the PLC5.4Integration in the robot controller5.5Tool change sequences5.6Recipe management by tool5.7Interlocks and checks5.8Error handling during the change5.9IO-Link Safety in interchangeable tools5.10Laboratory: change sequence with PLC and robot
6.1Cycle and usage counters6.2Condition monitoring6.3OPC UA and IO-Link6.4Integration with MES6.5Predictive tool maintenance6.6Traceability by tool6.7HMI visualisation6.8Alerts and events6.9Analysis of change times6.10Case study: tool status dashboard
7.1Multi-process cells with automatic change7.2Reducing change times7.3Small batches and high variety7.4Standardising tool interfaces7.5Total cost compared with dedicated cells7.6Safety during automatic change7.7Validation of the change7.8Documentation and training7.9Continuous improvement of the system7.10Practice: OEE analysis with automatic change
8.1Definition of the cell and tools8.2Selecting the changer8.3Design of utilities and storage8.4IO-Link network architecture8.5Programming the change sequence8.6Diagnostics and data8.7Validation and measurement of times8.8Technical documentation of the cell8.9Report and presentation8.10Final review with the tutor
How you'll learn
100% online training on the SEIUM campus, with downloadable material, recorded classes and assigned technical tutor. No fixed timetable: students progress at their own pace within the enrolment period, which makes it possible to combine the programme with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is Siemens TIA Portal, IO-Link Device Tool, SICK SOPAS ET, ifm moneo, Balluff Engineering Tool, in free, academic or evaluation versions. Tests are studied using real procedures for measuring tool change times, automatic parameterisation of IO-Link devices, and tool diagnostics in the cell. Assessment is continuous per module plus the final integrating project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Select tool changers according to the application.
Integrate pneumatic, electrical and signal utilities.
Configure IO-Link networks and their devices.
Automate parameterisation after the tool change.
Programme change sequences with PLC and robot.
Where this takes you
Requirements
- Prior technical training or professional experience in the sector. A university degree is not required.
- Internet connection and a computer capable of running the programme’s software.
- Sufficient command of Spanish to follow technical standards documentation.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme consists of 800 hours in total, spread over 6 to 8 months. That is between 10 and 15 hours per week on average, compatible with a full-time job.
The programme uses Siemens TIA Portal, IO-Link Device Tool, SICK SOPAS ET, ifm moneo and Balluff Engineering Tool. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.
An SEIUM own diploma upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.
Yes. Modules passed in a course or postgraduate diploma in the same area are credited towards the higher programme. Check the recognition policy when you enrol.
Related programmes
Postgraduate Diploma in Conformance and Latency Testing
Online 800 h postgraduate diploma in Conformance and Latency Testing. 8 modules covering IEC 61158, IEC 61784-2 and Wireshark. Assigned tutor and open enrolment.
Diploma in Train-the-Trainer XR and Impact Assessment
Online postgraduate diploma of 800 hours in XR train-the-trainer and impact evaluation: 8 modules covering adult learning and technical training, instructional design for XR, training trainers…
Postgraduate Diploma in Telemetry, KPIs and AMR Operations Control
Online 800-hour Postgraduate Diploma in Telemetry, KPIs and AMR Operations Control. 8 modules covering ISO 22400-2:2014, VDA 5050 v2.1 and Grafana. Assigned tutor and enrolment open.
More in Robotics, Automation & Control
All Robotics, Automation & Control programmes → · How to apply · Fees & financing · Scholarships