Postgraduate DiplomaNaval, Offshore & Sports Nautical Applications open

Postgraduate Diploma in Port Substation Design and Protection

Online 800-hour Postgraduate Diploma in Port Substation Design and Protection. 8 modules covering IEC 61936-1 (electrical installations above 1 kV AC), Royal Decree 337/2014 (Regulation on High-Voltage Electrical Installations, ITC-RAT) and ETAP. Assigned tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Analyse the electrical demand of a port, including shore power supply to berthed ships.

02

Design the configuration of a port substation.

03

Calculate short-circuit currents, load flows and voltage drops.

04

Coordinate the electrical protection system.

05

Design the earthing grid in accordance with IEEE 80.

06

Specify control and automation systems based on IEC 61850.

07

Plan the testing, commissioning and maintenance of the substation.

Profile

Who it's for

  • Substation engineer looking to specialise in Port Substation Design and Protection.
  • Electrical protection engineer looking to specialise in Port Substation Design and Protection.
  • Port electrical systems engineer looking to specialise in Port Substation Design and Protection.
  • Substation automation engineer looking to specialise in Port Substation Design and Protection.
  • Electrical maintenance manager looking to specialise in Port Substation Design and Protection.
  • Onshore power supply (OPS) connection engineer looking to specialise in Port Substation Design and Protection.
  • Graduates in engineering or science seeking to join port authorities.
Standards & tools

What you'll work with

  • IEC 61936-1 (electrical installations above 1 kV AC)
  • Royal Decree 337/2014 (Regulation on High-Voltage Electrical Installations, ITC-RAT)
  • IEEE 80 (earthing safety in substations)
  • IEC 60909 (calculation of short-circuit currents)
  • IEC 61850 (substation communication)
  • IEC/IEEE 80005-1 (electrical connection of ships in port)
  • IEC 60255 (measuring and protective relays)
Syllabus

8 modules · 800 h

  1. 1.1Electrical demand of a modern port
  2. 1.2Loads: cranes, refrigerated containers, OPS and lighting
  3. 1.3Electrification of yard equipment
  4. 1.4Port medium-voltage networks
  5. 1.5Connection to the distribution network
  6. 1.6High-voltage regulations (RD 337/2014)
  7. 1.7Low-voltage electrotechnical regulations
  8. 1.8Energy planning and growth
  9. 1.9Renewable generation in ports
  10. 1.10Case study: demand estimation for a terminal
  1. 2.1Typologies: outdoor, indoor and GIS
  2. 2.2Busbar arrangements
  3. 2.3Selection of power transformers
  4. 2.4Medium-voltage switchgear cubicles
  5. 2.5AC and DC auxiliary services
  6. 2.6Physical layout and clearances
  7. 2.7Marine environment and corrosion
  8. 2.8Flood protection
  9. 2.9Ventilation and air conditioning
  10. 2.10Workshop: single-line diagram of a port substation
  1. 3.1Load flow
  2. 3.2Short-circuit calculation (IEC 60909)
  3. 3.3Voltage drops in long cables
  4. 3.4Sizing of medium-voltage cables
  5. 3.5Harmonics from converters and cranes (IEEE 519)
  6. 3.6Reactive power compensation and filters
  7. 3.7Motor starting and voltage dips
  8. 3.8Simulation with ETAP or DIgSILENT
  9. 3.9Arc flash study (IEEE 1584)
  10. 3.10Practice: short-circuit study with software
  1. 4.1Protection philosophy
  2. 4.2Overcurrent and directional relays
  3. 4.3Transformer differential protection
  4. 4.4Protection of lines and cables
  5. 4.5Protection of cranes and OPS
  6. 4.6Coordination and selectivity
  7. 4.7Relay settings
  8. 4.8Earth fault protection
  9. 4.9IEC 61850 and protection communications
  10. 4.10Laboratory: protection selectivity study
  1. 5.1Earthing networks and step and touch voltages
  2. 5.2IEEE 80 and grid calculation
  3. 5.3Soil resistivity in port reclaimed land
  4. 5.4Lightning protection (IEC 62305)
  5. 5.5Equipotential bonding on quays
  6. 5.6Safety in switching operations and the 5 golden rules
  7. 5.7Interlocks
  8. 5.8Signage and PPE
  9. 5.9Electrical emergency plans
  10. 5.10Practice: earthing grid design
  1. 6.1Substation control system (SCS)
  2. 6.2Bay control units
  3. 6.3Telecontrol and SCADA
  4. 6.4Redundant communication networks
  5. 6.5Transformer monitoring
  6. 6.6Port energy management
  7. 6.7Integration with microgrids
  8. 6.8Cybersecurity (IEC 62443)
  9. 6.9Battery energy storage
  10. 6.10Case study: IEC 61850 control architecture
  1. 7.1Civil works and foundations
  2. 7.2Electromechanical assembly
  3. 7.3Factory acceptance tests (FAT)
  4. 7.4Site testing and commissioning
  5. 7.5Regulatory approval with the authorities
  6. 7.6Predictive substation maintenance
  7. 7.7Thermography and oil analysis
  8. 7.8Spare parts management
  9. 7.9Maintenance contracts
  10. 7.10Workshop: commissioning test protocol
  1. 8.1Design basis
  2. 8.2Demand estimation
  3. 8.3Single-line diagram
  4. 8.4Electrical calculations
  5. 8.5Protection study
  6. 8.6Earthing
  7. 8.7Control system
  8. 8.8Budget and works plan
  9. 8.9Report and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

A 100% online programme on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the enrolment period, which makes it easy to combine with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software includes ETAP, DIgSILENT PowerFactory, CYMGRD, AutoCAD Electrical, EPLAN, in free, academic or evaluation versions. Tests are studied using real commissioning procedures for protection systems, earthing resistance measurement and secondary injection testing of relays. Assessment is continuous, module by module, plus the final integrative project.

Accreditable laboratories(EN ISO/IEC 17025) with a rotor test rig, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-oriented final project:safety case, test plan, compliance dossier and operational limits.
Industry mentoring:lecturers with experience in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, with OT cybersecurity, DIH and compliance as its pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Design basis

Analyse the electrical demand of a port, including shore power supply to berthed ships.

Demand estimation

Design the configuration of a port substation.

Single-line diagram

Calculate short-circuit currents, load flows and voltage drops.

Electrical calculations

Coordinate the electrical protection system.

Protection study

Design the earthing grid in accordance with IEEE 80.

Career opportunities

Where this takes you

Substation engineerElectrical protection engineerPort electrical systems engineerSubstation automation engineerElectrical maintenance managerOnshore power supply (OPS) connection engineer
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. A university degree is not required.
  • Internet connection and a computer capable of running the programme's software.
  • A sufficient level of Spanish to follow technical regulatory texts.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme consists of 800 total hours spread over 6 to 8 months. That is an average of 10 to 15 hours per week, compatible with a full-time job.

You will work with ETAP, DIgSILENT PowerFactory, CYMGRD, AutoCAD Electrical and EPLAN. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

A SEIUM own diploma upon passing the continuous assessment and the integrative project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the advanced programme. Please consult the recognition policy when you enrol.

Postgraduate Diploma in Port Substation Design and ProtectionEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.