Postgraduate DiplomaElectromobility, Batteries & Hydrogen Applications open

Postgraduate Diploma in ADMS/DMS and Distributed Flexibility

Online 800-hour Postgraduate Diploma in ADMS/DMS and Distributed Flexibility. 8 modules covering IEC 61968, IEC 61970 and DIgSILENT PowerFactory. Assigned tutor and open enrolment.

Duration800 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Describe the architecture and functions of a modern ADMS system.

02

Apply advanced DMS functions such as FLISR and volt-var control.

03

Integrate distributed energy resources using standard protocols.

04

Design DERMS strategies for managing local congestion.

05

Analyse how local flexibility markets operate.

06

Assess cybersecurity risks in distribution control systems.

07

Plan the implementation of ADMS and DERMS solutions in a distribution utility.

Profile

Who it's for

  • Distribution network operations engineer looking to specialise in ADMS/DMS and Distributed Flexibility.
  • ADMS and DERMS systems specialist looking to specialise in ADMS/DMS and Distributed Flexibility.
  • Flexibility market analyst looking to specialise in ADMS/DMS and Distributed Flexibility.
  • Network automation engineer looking to specialise in ADMS/DMS and Distributed Flexibility.
  • Utilities digitalisation consultant looking to specialise in ADMS/DMS and Distributed Flexibility.
  • Distributed resource integration manager looking to specialise in ADMS/DMS and Distributed Flexibility.
  • Engineering or science graduates seeking to enter the electricity distribution sector.
Standards & tools

What you'll work with

  • IEC 61968
  • IEC 61970
  • IEC 61850-7-420
  • IEEE 1547-2018
  • IEEE 2030.5
  • Directiva (UE) 2019/944
  • IEC 62351
  • IEC 62443
Syllabus

8 modules · 800 h

  1. 1.1Evolution from SCADA to ADMS
  2. 1.2Functional architecture of an ADMS
  3. 1.3CIM network model according to IEC 61968/61970
  4. 1.4Integration with GIS and OMS
  5. 1.5State estimation in distribution
  6. 1.6Telecontrol via RTUs and concentrators
  7. 1.7IEC 60870-5-104 and DNP3 communications
  8. 1.8Availability and redundancy requirements
  9. 1.9Suppliers and the ADMS solutions market
  10. 1.10Case study: ADMS architecture for a distribution utility
  1. 2.1Fault location, isolation and service restoration
  2. 2.2Optimised volt-var control on feeders
  3. 2.3Optimal network reconfiguration
  4. 2.4Real-time load flow
  5. 2.5Outage management and scheduled works
  6. 2.6Contingency analysis in distribution
  7. 2.7Switching simulation for operators
  8. 2.8Load and distributed generation forecasting
  9. 2.9Management and reduction of technical losses
  10. 2.10Laboratory: FLISR simulation on a feeder
  1. 3.1Distributed photovoltaics and its control
  2. 3.2Network distributed storage
  3. 3.3Electric vehicles as a flexible resource
  4. 3.4Heat pumps and thermal loads
  5. 3.5Smart inverters according to IEEE 1547
  6. 3.6DER modeling according to IEC 61850-7-420
  7. 3.7IEEE 2030.5 and OpenADR protocols
  8. 3.8Aggregators and management platforms
  9. 3.9Visibility and observability of DER
  10. 3.10Practice: DER modeling in the ADMS
  1. 4.1Centralized and hierarchical DERM architectures
  2. 4.2Coordinated Dispatch of Distributed Resources
  3. 4.3Management of local network congestions
  4. 4.4Dynamic operating limits per knot
  5. 4.5Operation Envelope for each resource
  6. 4.6System operator integration
  7. 4.7Coordination between TSO and DSO
  8. 4.8EV recharge control from the distributor
  9. 4.9Verification of the flexibility delivered
  10. 4.10Workshop: Definition of operation envelope
  1. 5.1Directive (EU) 2019/944 and distribution managers
  2. 5.2Piclo, NODES and GOPACS platforms
  3. 5.3Availability and activation products
  4. 5.4Prequalification of flexibility providers
  5. 5.5Baseline and measurement verification
  6. 5.6Settlement and Penalties for Default
  7. 5.7Flexibility pilot projects in Spain
  8. 5.8Interaction with balance markets
  9. 5.9Design of local flexibility auctions
  10. 5.10Practical case: call for local flexibility
  1. 6.1Communications Cybersecurity according to IEC 62351
  2. 6.2Segmentation of OT networks according to IEC 62443
  3. 6.3Identity management on DER devices
  4. 6.4Integrity of measurement data
  5. 6.5Customer data privacy
  6. 6.6Incident response in OT environments
  7. 6.7NIS2 requirements for distributors
  8. 6.8Continuous security monitoring
  9. 6.9Penetration tests on OT systems
  10. 6.10Practice: DERMS risk analysis
  1. 7.1Selection of supplier and technical specifications
  2. 7.2Data migration and network model
  3. 7.3FAT and SAT acceptance tests
  4. 7.4Training of Control Center Operators
  5. 7.5SAIDI, SAIFI and loss indicators
  6. 7.6Assessment of benefits of digitization
  7. 7.7Organizational change management
  8. 7.8International Success Cases in ADMS
  9. 7.9Network Digitization Roadmap
  10. 7.10Case Study: ADMS Deployment Plan
  1. 8.1Diagnosis of the network and the DER
  2. 8.2Definition of priority use cases
  3. 8.3DERMS architecture design
  4. 8.4Proposed flexibility product
  5. 8.5Technical-economic evaluation of the solution
  6. 8.6Implementation Roadmap
  7. 8.7Solution Cybersecurity Analysis
  8. 8.8Project follow-up indicators
  9. 8.9Memory and presentation
  10. 8.10Final review with the tutor
Methodology, software & labs

How you'll learn

Training 100% online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: students progress at their own pace within the intake, which makes it possible to combine study with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is DIgSILENT PowerFactory, OpenDSS, GridLAB-D, pandapower, in free, academic or evaluation versions. Tests are studied using real operating procedures for distribution networks with high DER penetration, design of local flexibility products, and implementation of ADMS systems in distribution utilities. Assessment is continuous by module plus the final integrating project.

Accreditable laboratories(EN ISO/IEC 17025) with rotor bench, EMC/Lightning pre-compliance, HIL/SIL, vibrations/acoustics.
Evidence-oriented Master's Thesis:safety case, test plan, compliance dossier and operational limits.
Industry Mentored:teachers with experience in training, , eVTOL/UAM and flight test.
Flexible modality(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:safety-by-design approach, cyber-OT, DIH and compliance as pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Diagnosis of the network and DERs

Describe the architecture and functions of a modern ADMS system.

Definition of priority use cases

Apply advanced DMS functions such as FLISR and volt-var control.

DERMS architecture design

Integrate distributed energy resources using standard protocols.

Proposed flexibility product

Design DERMS strategies for managing local congestion.

Technical and economic evaluation of the solution

Analyse how local flexibility markets operate.

Career opportunities

Where this takes you

Distribution network operations engineerADMS and DERMS systems specialistFlexibility market analystNetwork automation engineerUtilities digitalisation consultantDistributed resource integration manager
Admissions & scholarships

Requirements

  • Prior technical training or professional experience in the sector. A university degree is not required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient Spanish to follow technical regulatory texts.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 800 hours spread over 6 to 8 months. That is between 10 and 15 hours per week on average, compatible with a full-time job.

You will work with DIgSILENT PowerFactory, OpenDSS, GridLAB-D and pandapower. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

An own diploma from SEIUM upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area can be credited towards the higher programme. Check the credit transfer policy when you enrol.

Postgraduate Diploma in ADMS/DMS and Distributed FlexibilityEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.