Master'sNuclear Engineering & Nuclear Fuel Cycle Technologies Applications open

Master’s in Radiation Protection (IAEA/ICRP) and Dosimetry Engineering

Online master's programme of 1,900 hours in radiation protection (IAEA/ICRP) and dosimetry engineering. 12 modules covering the international radiation protection system, ICRU quantities, external, neutron and internal dosimetry, computational dosimetry, metrology, occupational, medical and public exposure, optimisation and emergencies, with ICRP Publication 103, IAEA GSR Part 3 and Geant4, with an assigned technical tutor.

Duration1900 h
ModeOnline
LanguageEnglish
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Understand the international radiation protection system of the ICRP and the IAEA.

02

Apply protection and operational quantities correctly.

03

Perform external dosimetry of photons, electrons and neutrons.

04

Calculate internal doses with ICRP biokinetic models.

05

Use Monte Carlo methods in computational dosimetry.

06

Ensure the metrological traceability of measurements.

07

Manage occupational, medical and public protection.

Profile

Who it's for

  • Dosimetry specialists.
  • Radiation protection technicians.
  • Heads of personal dosimetry services.
  • Ionising radiation metrologists.
  • Computational dosimetry researchers.
  • Radiation protection consultants.
  • Engineering or science graduates seeking to join a dosimetry service.
Standards & tools

What you'll work with

  • ICRP Publication 103 (recommendations of the International Commission on Radiological Protection)
  • IAEA GSR Part 3 (radiation protection and safety of radiation sources)
  • Directive 2013/59/Euratom (basic safety standards for radiation protection)
  • ICRU Report 95 (operational quantities for external radiation exposure)
  • ICRP Publication 116 (conversion coefficients for external exposure)
  • ISO 4037 (X and gamma reference radiation for calibration)
  • IAEA GSG-7 (occupational radiation protection)
  • Royal Decree 1029/2022 (Spanish regulation on protection against ionising radiation)
  • Geant4
  • MCNP
  • PENELOPE
  • IDEAS
  • IMBA
Syllabus

12 modules · 1900 h

  1. 1.1History of the ICRP and its recommendations
  2. 1.2Relationship between ICRP, IAEA, UNSCEAR and ICRU
  3. 1.3ICRP Publication 103 and what it introduced
  4. 1.4Basic safety standards GSR Part 3
  5. 1.5Directive 2013/59/Euratom and its transposition
  6. 1.6Detriment and nominal risk coefficients
  7. 1.7Radiation and tissue weighting factors
  8. 1.8ICRP 110 reference phantoms
  9. 1.9Ongoing review of the ICRP system
  10. 1.10Case study: comparison of limits between ICRP 60 and 103
  1. 2.1Physical quantities: fluence, kerma and dose
  2. 2.2Protection quantities and why they cannot be measured
  3. 2.3Ambient and directional dose equivalent
  4. 2.4Personal dose equivalent Hp(10), Hp(3) and Hp(0.07)
  5. 2.5ICRP 116 conversion coefficients
  6. 2.6ICRU Report 95 and the new operational quantities
  7. 2.7ICRU sphere and calibration phantoms
  8. 2.8Linear energy transfer and radiation quality
  9. 2.9Microdosimetry and lineal energy
  10. 2.10Workshop: conversion of fluence to operational quantities
  1. 3.1Film dosimeters and their history
  2. 3.2Thermoluminescence dosimetry (TLD)
  3. 3.3Optically stimulated luminescence dosimetry (OSL)
  4. 3.4Direct-reading electronic dosimeters
  5. 3.5Dose calculation algorithms
  6. 3.6Eye lens dosimetry after ICRP 118
  7. 3.7Extremity dosimetry in nuclear medicine
  8. 3.8Energy and angular response
  9. 3.9EURADOS dosimetry intercomparisons
  10. 3.10Laboratory: response characterisation of TLD dosimeters
  1. 4.1Neutron spectra in the workplace
  2. 4.2Bonner spheres and spectrometry
  3. 4.3Rem meters and their response
  4. 4.4CR-39 track dosimeters
  5. 4.5Bubble dosimeters
  6. 4.6Mixed neutron-gamma fields
  7. 4.7Dosimetry around medical accelerators
  8. 4.8Calibration with Am-Be and Cf-252 sources
  9. 4.9Uncertainties in neutron dosimetry
  10. 4.10Practical exercise: unfolding a spectrum with Bonner spheres
  1. 5.1Intake pathways for radionuclides
  2. 5.2Human respiratory tract model
  3. 5.3Human alimentary tract model
  4. 5.4Systemic biokinetic models
  5. 5.5The ICRP OIR series: Publications 130 to 141
  6. 5.6Dose coefficients for intake
  7. 5.7In vivo measurements with whole-body counters
  8. 5.8Urine and faecal bioassays
  9. 5.9IDEAS software and interpretation guidelines
  10. 5.10Practical exercise: committed dose from an iodine-131 intake
  1. 6.1Monte Carlo methods in dosimetry
  2. 6.2MCNP, Geant4 and PENELOPE codes
  3. 6.3Voxel and mesh phantoms
  4. 6.4Calculation of conversion coefficients
  5. 6.5Patient dosimetry in imaging
  6. 6.6Dose reconstruction in accidents
  7. 6.7Biological dosimetry using chromosome aberrations
  8. 6.8Validation of computational models
  9. 6.9High-performance computing in dosimetry
  10. 6.10Laboratory: dose simulation in a phantom with Geant4
  1. 7.1Primary and secondary standards
  2. 7.2Dosimetry calibration laboratories
  3. 7.3ISO 4037 reference beams
  4. 7.4Calibration of ionisation chambers
  5. 7.5Traceability to the International System of Units
  6. 7.6Uncertainty calculation according to the GUM
  7. 7.7ISO/IEC 17025 accreditation
  8. 7.8BIPM key comparisons
  9. 7.9IAEA/WHO laboratory network
  10. 7.10Workshop: uncertainty budget for a calibration
  1. 8.1Occupational radiation protection programme
  2. 8.2Individual and workplace monitoring
  3. 8.3Approved personal dosimetry services
  4. 8.4Central dose register
  5. 8.5Pregnant and breastfeeding workers
  6. 8.6Outside workers and their control
  7. 8.7Radon exposure in workplaces
  8. 8.8Aircrew and cosmic radiation
  9. 8.9IAEA guide GSG-7
  10. 8.10Case study: dosimetric monitoring in nuclear medicine
  1. 9.1Justification of medical exposures
  2. 9.2Diagnostic reference levels
  3. 9.3Patient dose in CT and interventional procedures
  4. 9.4Public exposure from effluents
  5. 9.5The representative person concept
  6. 9.6Existing exposure from residential radon
  7. 9.7National radon action plan
  8. 9.8NORM and building materials
  9. 9.9Activity concentration index
  10. 9.10Practical exercise: estimating annual radon dose in dwellings
  1. 10.1Quantitative optimisation tools
  2. 10.2Cost-benefit analysis and the monetary value of the sievert
  3. 10.3Corporate ALARA programmes
  4. 10.4Dose constraints
  5. 10.5Safety assessment of sources
  6. 10.6Risk analysis with risk matrices
  7. 10.7Communicating radiological risk
  8. 10.8Ethics of radiation protection (ICRP 138)
  9. 10.9Radiation protection culture
  10. 10.10Case study: optimisation of an interventional procedure
  1. 11.1Emergency exposure situations
  2. 11.2Reference levels in emergencies
  3. 11.3GSR Part 7 generic criteria
  4. 11.4Urgent dosimetry and triage
  5. 11.5Retrospective dosimetry using EPR and OSL
  6. 11.6The Goiânia and Chernobyl accidents
  7. 11.7Medical management of overexposures
  8. 11.8Transition to an existing exposure situation
  9. 11.9ICRP Publication 146
  10. 11.10Workshop: dose reconstruction after an overexposure
  1. 12.1Definition of the dosimetric problem
  2. 12.2Regulatory and literature review
  3. 12.3Design of the measurement or calculation methodology
  4. 12.4Data acquisition and processing
  5. 12.5Uncertainty assessment
  6. 12.6Analysis of results against limits
  7. 12.7Proposals to improve protection
  8. 12.8Conclusions of the dosimetric work
  9. 12.9Master's Thesis report
  10. 12.10Master's Thesis: defence before a panel
Methodology, software & labs

How you'll learn

100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within each intake, making it compatible with full-time work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is Geant4, MCNP, PENELOPE, IDEAS and IMBA, in free, academic or evaluation versions. Tests are studied using real procedures for calibrating dosimeters and monitors, calculating internal dose from intakes and Monte Carlo dose simulation. Assessment is continuous for each module, plus the final Master's Thesis.

Standards covered: ICRP Publication 103, IAEA GSR Part 3 Radiation Protection and Safety of Radiation Sources, Directive 2013/59/Euratom, ICRU Report 95, ICRP Publication 116, ISO 4037, IAEA GSG-7 Occupational Radiation Protection and Royal Decree 1029/2022.

Assigned technical tutor:every module ends with a deliverable that your tutor marks individually.
Standards-based learning:guided reading of ICRP Publication 103, IAEA GSR Part 3 and Directive 2013/59/Euratom applied to real cases, not as a theoretical annex.
Industry software:Geant4, MCNP, PENELOPE, IDEAS and IMBA, in free, academic or evaluation versions.
Master's Thesis with defence:a dosimetric study with its own measurement or calculation methodology, uncertainty assessment and analysis of results against limits, defended before a panel.
Flexible format:100% online, no fixed timetables, compatible with full-time work.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Dosimeter characterisation
You characterise the energy and angular response of TLD dosimeters.
Internal dose assessment
You calculate the committed dose from an iodine-131 intake using bioassay data and IDEAS.
Monte Carlo simulation
You simulate dose distribution in a phantom with Geant4.
Calibration uncertainty budget
You build the uncertainty budget for a dosimetric calibration according to the GUM.
Master's Thesis
A dosimetric study with its own measurement or calculation methodology, uncertainty assessment and comparison against limits, defended before a panel.
Career opportunities

Where this takes you

Dosimetry specialistRadiation protection technicianHead of personal dosimetry serviceIonising radiation metrologistComputational dosimetry researcherRadiation protection consultant
Admissions & scholarships

Requirements

  • A university degree in engineering, science or architecture, or equivalent demonstrable professional experience.
  • An internet connection and a computer capable of running the programme software.
  • English sufficient to read technical standards.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.

You work with Geant4, MCNP, PENELOPE, IDEAS and IMBA, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.

A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.

A university degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the programme software and English sufficient to read technical standards.

Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.

Master’s in Radiation Protection (IAEA/ICRP) and Dosimetry EngineeringEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.