Master’s in Nuclear Medicine and Diagnostic Radiology Technology Engineering
Online master's programme of 1,900 hours in nuclear medicine and diagnostic radiology technology engineering, with an engineering focus. 12 modules covering imaging physics, radiology and CT equipment, radiopharmaceuticals, gamma camera, SPECT and PET, MRI and ultrasound, image processing and AI, radiation protection, hospital technology management and quality, with Directive 2013/59/Euratom, IEC 60601-2-44 and 3D Slicer, with an assigned technical tutor.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Understand the physics of medical image formation.
Analyse how diagnostic radiology and CT equipment works.
Understand the production and quality control of radiopharmaceuticals.
Evaluate the performance of gamma cameras, SPECT and PET.
Apply image processing and artificial intelligence techniques.
Optimise radiation protection in medical imaging.
Manage the quality and life cycle of hospital technology.
Who it's for
- Clinical engineers (electromedicine).
- Imaging quality control specialists.
- Medical imaging application engineers.
- Radiopharmacy technicians.
- Hospital technology managers.
- Medical imaging researchers.
- Engineering or science graduates seeking to work in hospitals and healthcare.
What you'll work with
- Directive 2013/59/Euratom (basic safety standards, including medical exposure)
- IEC 60601-2-44 (safety of X-ray equipment for computed tomography)
- NEMA NU 2 (performance measurements of PET scanners)
- NEMA NU 1 (performance measurements of gamma cameras)
- Regulation (EU) 2017/745 (medical devices)
- Royal Decree 1976/1999 (Spanish quality criteria in diagnostic radiology)
- Royal Decree 1841/1997 (Spanish quality criteria in nuclear medicine)
- DICOM PS3 (digital imaging and communications in medicine)
- 3D Slicer
- ImageJ
- MATLAB
- GATE
- Horos
12 modules · 1900 h
1.1X-ray production and spectra1.2Photon interactions in tissue1.3Formation of the radiographic image1.4Contrast, noise and spatial resolution1.5Modulation transfer function1.6Detective quantum efficiency1.7Linear systems theory in imaging1.8Image quality and observers1.9Dose and image quality1.10Workshop: MTF measurement with the slanted-edge method
2.1X-ray tubes and generators2.2Flat-panel detectors2.3Direct and indirect digital radiography2.4Mammography and tomosynthesis2.5Fluoroscopy and C-arms2.6Interventional radiology equipment2.7Orthopantomography and dental CBCT2.8Mobile radiology equipment2.9DICOM and PACS integration2.10Practical exercise: quality control of a digital radiography unit
3.1Principles of CT acquisition3.2Filtered back-projection reconstruction3.3Iterative and deep learning reconstruction3.4Multislice and dual-energy CT3.5Photon-counting CT3.6CTDI and DLP dose indices3.7Tube current modulation3.8CT artefacts and their correction3.9Protocol optimisation3.10Laboratory: tomographic reconstruction with Python
4.1Properties of radionuclides for imaging4.2Technetium-99m generators4.3Production of fluorine-18 in a cyclotron4.4Synthesis of PET radiopharmaceuticals4.5Theranostic radionuclides: lutetium-177 and gallium-684.6Quality control of radiopharmaceuticals4.7Good manufacturing practice4.8Organisation of hospital radiopharmacies4.9Nuclear medicine waste management4.10Case study: logistics of a centralised radiopharmacy
5.1Collimators and their design5.2Scintillation crystals and photomultipliers5.3CZT detectors5.4Positioning electronics5.5SPECT reconstruction and attenuation correction5.6Hybrid SPECT/CT systems5.7Uniformity and linearity5.8NEMA NU 1 quality control5.9Quantification in SPECT5.10Practical exercise: gamma camera uniformity test
6.1Coincidence and annihilation principle6.2LSO and LYSO detectors6.3Time of flight (TOF)6.4Total-body PET6.5PET/CT and PET/MR6.6OSEM iterative reconstruction6.7Scatter and randoms corrections6.8Quantification using SUV values6.9NEMA NU 2 tests6.10Laboratory: NEMA performance analysis of a PET scanner
7.1Physics of nuclear magnetic resonance7.2Gradients and spatial encoding7.3Pulse sequences7.4Safety in magnetic resonance7.5Ultrasound equipment and transducers7.6Doppler and elastography7.7Quality control in magnetic resonance7.8Multimodal image fusion7.9Fundamentals of molecular imaging7.10Case study: risk analysis of an MRI suite
8.1DICOM format and its objects8.2Digital image processing8.3Organ segmentation8.4Image registration8.5Radiomics and feature extraction8.6Artificial intelligence in diagnosis8.7Software as a medical device8.8Cybersecurity of medical equipment8.9Clinical validation of algorithms8.10Workshop: segmentation of a CT scan with 3D Slicer
9.1Justification and optimisation in diagnosis9.2Diagnostic reference levels9.3Patient dosimetry9.4Protection of paediatric patients9.5Pregnancy and medical exposure9.6Staff protection in interventional procedures9.7Shielding of imaging rooms9.8Protection in nuclear medicine and radionuclide therapy9.9Patient dose recording9.10Practical exercise: dose audit of a CT department
10.1Planning imaging equipment10.2Health technology assessment10.3Procurement and technical specifications10.4Equipment maintenance10.5Life cycle management10.6Utilisation and availability indicators10.7Equipment installation projects10.8Medical Devices Regulation 2017/74510.9Electromagnetic compatibility in hospitals10.10Case study: technical procurement specification for a PET/CT
11.1Quality assurance programme11.2Spanish Royal Decree on quality in diagnostic radiology11.3Spanish Royal Decree on quality in nuclear medicine11.4Spanish Quality Control Protocol in Diagnostic Radiology11.5IEC 60601 standards11.6NEMA performance standards11.7Clinical audits of radiological practice11.8Accreditation of departments11.9Incident management11.10Workshop: design of a quality control programme
12.1Selection of the modality or problem12.2Technical and regulatory review12.3Experimental or simulation design12.4Data acquisition and analysis12.5Assessment of image quality and dose12.6Optimisation proposal12.7Clinical and economic impact12.8Engineering conclusions12.9Master's Thesis report12.10Master's Thesis: defence before a panel
How you'll learn
100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within each intake, making it compatible with full-time work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is 3D Slicer, ImageJ, MATLAB, GATE and Horos, in free, academic or evaluation versions. Tests are studied using real procedures for quality control of imaging equipment, CT protocol optimisation and quantitative PET and SPECT analysis. Assessment is continuous for each module, plus the final Master's Thesis.
Standards covered: Directive 2013/59/Euratom, IEC 60601-2-44, NEMA NU 2, NEMA NU 1, Regulation (EU) 2017/745 on medical devices, Royal Decree 1976/1999 (quality criteria in diagnostic radiology), Royal Decree 1841/1997 (quality criteria in nuclear medicine) and DICOM PS3.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Where this takes you
Requirements
- A university degree in engineering, science or architecture, or equivalent demonstrable professional experience.
- An internet connection and a computer capable of running the programme software.
- English sufficient to read technical standards.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.
You work with 3D Slicer, ImageJ, MATLAB, GATE and Horos, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.
A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.
A university degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the programme software and English sufficient to read technical standards.
Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.
Related programmes
Master’s in Radioactive Waste Management and Deep Geological Disposal Engineering
Online master's programme of 1,900 hours in radioactive waste management and deep geological disposal engineering. 12 modules covering waste origin and classification, predisposal management, disposal concepts,…
Master’s in Nuclear Energy Policy, Economics and Project Finance Engineering
Online master's programme of 1,900 hours in nuclear energy policy, economics and project finance engineering. 12 modules covering electricity markets, the economics of nuclear generation, project…
Master’s in SMRs, Micro-Reactors & Industrial Uses Engineering
Online master's programme of 1,900 hours in SMR, microreactor and industrial applications engineering, structured in 12 modules covering small modular reactors, light water and Generation IV…
More in Nuclear Engineering & Nuclear Fuel Cycle Technologies
All Nuclear Engineering & Nuclear Fuel Cycle Technologies programmes → · How to apply · Fees & financing · Scholarships