Master’s in Distribution Engineering, ADMS & Low Voltage
Online master's programme of 1,900 hours in distribution, ADMS and low-voltage engineering. 12 modules covering MV and LV network design, unbalanced network analysis, ADMS and DERMS, FLISR automation, distribution protection, self-consumption, smart metering, local flexibility markets and distribution regulation, with an assigned technical tutor.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Design medium- and low-voltage networks in line with regulations.
Analyse unbalanced distribution networks with distributed generation.
Specify ADMS systems for network management.
Implement automation and FLISR schemes.
Coordinate protection in networks with distributed generation.
Use smart metering data for operations.
Integrate flexibility into distribution management.
Who it's for
- Distribution network engineers.
- ADMS operations engineers.
- Distribution network planners.
- Network automation specialists.
- Metering data analysts.
- Distributed generation connection engineers.
- Engineering or science graduates aiming to move into electricity distribution.
What you'll work with
- Royal Decree 842/2002 (Spanish low-voltage electrotechnical regulations)
- Royal Decree 337/2014 (Spanish regulation on high-voltage electrical installations)
- Royal Decree 223/2008 (high-voltage lines)
- Royal Decree 1955/2000 (transmission, distribution and quality of service)
- Royal Decree 244/2019 (self-consumption)
- Royal Decree 1183/2020 (access and connection)
- UNE-EN 50160 (voltage characteristics of supplied electricity)
- IEC 61968 (CIM for distribution)
- OpenDSS
- DIgSILENT PowerFactory
- CYMDIST
- QGIS
- Python (pandapower)
12 modules · 1900 h
1.1Medium- and low-voltage networks in Spain1.2Radial, ring and meshed topologies1.3Secondary substations and their types1.4Overhead and underground distribution lines1.5Distributed generation and reverse flows1.6Electrification of demand1.7The role of the distribution system operator1.8Quality of supply and obligations1.9Digitalisation indicators1.10Case study: diagnosis of an urban medium-voltage network
2.1Calculation of cross-sections and voltage drops2.2Selection of conductors and cables2.3Medium-voltage switchgear2.4Prefabricated secondary substations2.5Earthing in secondary substations2.6Applicable high-voltage regulations2.7Distribution companies' specific standards2.8Planning criteria2.9Extensions and reinforcements2.10Practical exercise: design of a 20 kV underground line
3.1Low-voltage electrotechnical regulations3.2TT, TN and IT earthing systems3.3Service connections and main protection boxes3.4Calculation of low-voltage networks3.5Phase imbalances3.6Self-consumption at low voltage3.7Electric vehicle charging at low voltage3.8Low-voltage monitoring3.9Hosting capacity at low voltage3.10Laboratory: analysis of a low-voltage network with OpenDSS
4.1Unbalanced three-phase load flow4.2Models of loads and distributed generation4.3Loss analysis4.4Voltage regulation4.5Short circuits in distribution4.6Time-series analysis4.7Generation hosting capacity4.8State estimation in distribution4.9Analysis tools4.10Practical exercise: calculation of photovoltaic hosting capacity
5.1Architecture of an ADMS5.2Distribution SCADA5.3Outage management system (OMS)5.4Network management with DMS5.5Integration with GIS5.6Distributed energy resource management (DERMS)5.7CIM network model5.8Advanced analysis applications5.9Selection and implementation5.10Case study: ADMS requirements for a medium-sized distribution company
6.1Remote control of secondary substations6.2Reclosers and sectionalisers6.3Fault location, isolation and service restoration (FLISR)6.4Automatic network reconfiguration6.5Voltage and reactive power control6.6Fault passage indicators6.7Communications for automation6.8Distributed and centralised logic6.9Benefits for quality indices6.10Laboratory: simulation of a FLISR scheme
7.1Overcurrent protection7.2Neutral and earth fault protection7.3Coordination of fuses and relays7.4Impact of distributed generation7.5Protection in compensated neutral networks7.6Auto-reclosing on overhead lines7.7Protection of secondary substations7.8Low-voltage protection7.9Adaptive protection settings7.10Practical exercise: coordination study for a feeder
8.1Self-consumption regulations8.2Connection of generation to distribution8.3Technical connection requirements8.4Inverters and grid functions8.5Distributed storage at low voltage8.6Local energy communities8.7Voltage control with inverters8.8Zero export and power limitation8.9Impact on planning8.10Case study: connection of 5 MW at medium voltage
9.1Smart meters in Spain9.2Remote management systems9.3Load profile data9.4Analytics for the low-voltage network9.5Detection of fraud and non-technical losses9.6Phase identification9.7Data quality9.8Consumer access to their data9.9Privacy of consumption data9.10Laboratory: phase identification with meter data
10.1Congestion in distribution10.2Flexibility services for the distribution system operator10.3Local flexibility markets10.4Coordination with the system operator10.5Investment plans with flexibility10.6Flexible generation connections10.7Managed electric vehicle charging10.8Regulation of flexibility10.9European flexibility experiences10.10Workshop: design of a local flexibility tender
11.1Distribution remuneration11.2Incentives for quality and losses11.3Investment plans11.4Access and connection procedures11.5Quality of service and penalties11.6Asset management11.7Cybersecurity in distribution11.8Digitalisation and regulation11.9The EU DSO Entity11.10Case study: analysis of a distribution company's investment plan
12.1Selection of the study network12.2Network modelling and analysis12.3Diagnosis of problems12.4Automation or ADMS proposal12.5Integration of distributed resources12.6Technical and economic assessment12.7Implementation plan12.8Conclusions and future work12.9Master's Thesis report12.10Master's Thesis: defence before a panel
How you'll learn
The programme is delivered 100% online on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: you progress at your own pace within each intake, so it can be combined with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is OpenDSS, DIgSILENT PowerFactory, CYMDIST, QGIS and Python (pandapower), in free, academic or evaluation versions. Work is based on real procedures for low-voltage hosting capacity analysis, FLISR scheme simulation and protection coordination studies. Assessment is continuous by module, plus the final Master's Thesis.
Standards covered: Royal Decree 842/2002, Royal Decree 337/2014, Royal Decree 223/2008, Royal Decree 1955/2000, Royal Decree 244/2019, Royal Decree 1183/2020, UNE-EN 50160, IEC 61968.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Where this takes you
Requirements
- University degree in engineering, science or architecture, or equivalent demonstrable professional experience.
- Internet connection and a computer capable of running the programme software.
- English sufficient to read technical standards.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.
You work with OpenDSS, DIgSILENT PowerFactory, CYMDIST, QGIS and Python (pandapower), using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.
A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.
A degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the programme software, and English sufficient to read technical standards.
Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.
Related programmes
Master’s in Energy Retrofitting Engineering and Certification
Online master's programme of 1,900 hours in energy retrofit and certification engineering: 12 modules covering existing building physics, energy performance certification, simulation tools, envelope and installation…
Master’s in HVDC Engineering and Multi-Terminal Links
Online master's programme of 1,900 hours in HVDC and multi-terminal link engineering. 12 modules covering LCC and VSC/MMC technology, control of point-to-point links, DC cables, multi-terminal…
Master’s in Utility-Scale BESS Engineering
Online master's programme of 1,900 hours in utility-scale BESS engineering, structured in 12 modules covering battery technologies, system architecture, sizing, fire safety to IEC 62933-5-2 and…
More in Energy and Networks
All Energy and Networks programmes → · How to apply · Fees & financing · Scholarships