Master’s in Data Centre Energy Engineering
Online master's programme of 1,900 hours in energy engineering for data centres: 12 modules covering efficiency metrics, electrical architecture, UPS and backup generation, efficient cooling, heat reuse, renewable supply, grid integration, monitoring, and design, regulation and certification, with an assigned technical tutor.
Take the controls.
Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Measure data centre efficiency with standardised metrics.
Design redundant electrical architectures.
Size uninterruptible power supply and backup systems.
Select efficient cooling strategies.
Assess the reuse of waste heat.
Plan renewable supply and grid integration.
Apply the sector's standards and regulatory requirements.
Who it's for
- Data centre infrastructure engineers.
- Data centre energy managers.
- Cooling engineers working on high-density facilities.
- Digital sustainability consultants.
- Mission-critical electrical engineers.
- Renewable supply analysts serving digital infrastructure.
- Engineering or science graduates aiming to move into the data centre sector.
What you'll work with
- UNE-EN 50600 (data centre facilities and infrastructures)
- ISO/IEC 30134-2 (PUE, power usage effectiveness)
- Directive (EU) 2023/1791 (Energy Efficiency Directive)
- Delegated Regulation (EU) 2024/1364 (common rating scheme for data centres)
- ASHRAE TC 9.9 Thermal Guidelines (data processing environments)
- IEC 62040-3 (UPS performance)
- Real Decreto 842/2002 (REBT, Spanish low-voltage electrical regulation)
- EU Code of Conduct for Data Centre Energy Efficiency (voluntary best-practice scheme)
- 6SigmaDCX
- EcoStruxure IT
- ETAP
- Python (pandas)
- EnergyPlus
12 modules · 1900 h
1.1Growth of digital demand1.2Electricity consumption of data centres1.3Artificial intelligence and power density1.4Types: hyperscale, colocation and edge1.5Availability classification by tiers1.6Siting and energy criteria1.7The data centre market in Spain1.8Impact on the power grid1.9Sustainability of the sector1.10Case study: energy analysis of a hyperscale campus
2.1PUE: definition and measurement2.2WUE and CUE2.3ERF and energy reuse2.4REF and renewable energy factor2.5Metrics in the ISO/IEC 30134 series2.6Reporting under the Energy Efficiency Directive2.7Benchmarking between facilities2.8Measurement errors2.9Continuous efficiency improvement2.10Lab: PUE calculation from sub-metering data
3.1High- and medium-voltage supply3.2Data centre substations3.3Low-voltage distribution3.4N+1 and 2N redundancy3.5Switchboards and busbar trunking3.6Rack-level distribution and PDUs3.7400 V DC distribution3.8Discrimination and protection3.9Power quality in data centres3.10Practical exercise: single-line diagram of a 2 MW data hall
4.1UPS technologies4.2Scalable modular UPS4.3Lead-acid and lithium batteries4.4Flywheels4.5UPS efficiency4.6High-efficiency eco modes4.7UPS as a grid resource4.8Battery maintenance4.9Lithium battery safety4.10Lab: sizing a UPS with 10 minutes of autonomy
5.1Diesel generator sets5.2HVO renewable fuels5.3Fuel cells5.4Periodic load testing5.5Emissions and permits5.6Fuel storage5.7Start-up and transfer5.8Battery-based backup5.9Combustion-free alternatives5.10Case study: replacing diesel generators with HVO and batteries
6.1Thermal loads of servers6.2Chillers and free cooling6.3Direct and indirect evaporative cooling6.4Aisle containment6.5Direct-to-chip liquid cooling6.6Immersion cooling6.7ASHRAE recommended temperatures6.8CFD simulation of data halls6.9Water consumption6.10Practical exercise: CFD simulation of a contained data hall
7.1Waste heat from data centres7.2Heat pumps to raise temperature7.3Connection to district heating networks7.4Industrial and agricultural uses7.5Nordic heat reuse experience7.6Obligations under the Energy Efficiency Directive7.7Technical and economic feasibility7.8Heat supply contracts7.9Urban planning of data centres7.10Lab: feasibility of connecting to a district heating network
8.1Long-term renewable PPAs8.224/7 hourly matching8.3Guarantees of origin8.4Self-consumption in data centres8.5Storage on campus8.6Emissions accounting8.7Carbon neutrality targets8.8Sustainability reporting8.9Greenwashing and credibility8.10Case study: 24/7 carbon-free supply strategy
9.1Access and connection of large loads9.2Connection timescales9.3Demand capacity tenders9.4Data centre flexibility9.5Shiftable AI workloads9.6Balancing services9.7Quality of supply9.8Coordination with the system operator9.9Network planning9.10Practical exercise: load flexibility of an AI data centre
10.1DCIM and BMS10.2Energy monitoring by data hall10.3Digital twins of data centres10.4AI-based cooling optimisation10.5Predictive maintenance of critical equipment10.6Capacity management10.7Operational availability indicators10.8Cybersecurity of building systems10.9Mandatory energy audits10.10Workshop: energy dashboard for a data centre
11.1EN 50600 for facilities11.2Availability certifications11.3European Code of Conduct for Data Centres11.4Fire protection regulations11.5Licences and permitting11.6Environmental assessment of the project11.7Requirements of the Energy Efficiency Directive11.8EU Taxonomy and data centres11.9Prefabricated modular construction11.10Case study: EN 50600 checklist for a project
12.1Definition of the data centre12.2Design of the electrical architecture12.3Cooling strategy12.4Heat reuse12.5Renewable supply strategy12.6Grid integration12.7Efficiency assessment12.8Conclusions and future lines of work12.9Master's Thesis report12.10Master's Thesis: defence before a panel
How you'll learn
100% online training on the SEIUM campus, with downloadable materials, recorded classes and an assigned technical tutor. There is no fixed timetable: you progress at your own pace within the intake, so it is compatible with full-time work.
Each module combines theory, guided reading of the original standards and applied exercises. The working software is 6SigmaDCX, EcoStruxure IT, ETAP, Python (pandas) and EnergyPlus, in free, academic or evaluation versions. Practical work is based on real procedures: energy efficiency measurement of data halls, CFD cooling simulation and heat reuse studies. Assessment is continuous by module, plus the final Master's Thesis.
Standards covered: UNE-EN 50600, ISO/IEC 30134-2, Directive (EU) 2023/1791, Delegated Regulation (EU) 2024/1364, ASHRAE TC 9.9 Thermal Guidelines, IEC 62040-3, Real Decreto 842/2002, EU Code of Conduct for Data Centre Energy Efficiency.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Where this takes you
Requirements
- A university degree in engineering, science or architecture, or equivalent demonstrable professional experience.
- An internet connection and a computer capable of running the programme's software.
- English sufficient to read technical standards.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 1,900 hours over 12–14 months. You set your own pace within each intake, and your tutor helps you plan the workload around your job.
You work with 6SigmaDCX, EcoStruxure IT, ETAP, Python (pandas) and EnergyPlus, using free, academic or evaluation versions. Your tutor indicates the free alternative wherever one exists.
A SEIUM Institute diploma, awarded on passing the continuous assessment and the Master's Thesis. It is SEIUM's own qualification, not an official state degree; its recognition depends on the programme completed and the regulations of each country.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the higher programme. Ask about the recognition policy when you enrol.
A degree in engineering, science or architecture (or equivalent professional experience), a computer able to run the programme's software and English sufficient to read technical standards.
Start dates are set by SEIUM's faculty for each intake. Our admissions team will confirm the next available date when you apply.
Related programmes
Master’s in Probabilistic Analysis and Network Resilience Engineering
Online master's programme of 1,900 hours in probabilistic analysis and power network resilience engineering. 12 modules covering reliability and adequacy, Monte Carlo methods, extreme events and…
Master’s in Transmission Engineering, FACTS & HVDC
Online master's programme of 1,900 hours in transmission, FACTS and HVDC engineering. 12 modules covering overhead line and cable design, power electronics, FACTS devices, LCC and…
Master’s in Financial Engineering, Contracts & Sustainability
Online master's programme of 1,900 hours in finance, contracts and sustainability engineering for the energy sector, structured in 12 modules covering project economics, project finance, PPAs,…
More in Energy and Networks
All Energy and Networks programmes → · How to apply · Fees & financing · Scholarships