Energy Engineering in Data Centres Course
The Energy Engineering in Data Centres Course explores the design, optimisation and management of energy infrastructure in data centres. It focuses on energy efficiency, cooling, uninterruptible power supply systems (UPS), and the use of renewable energy to minimise environmental impact and reduce operating costs. It analyses key performance indicators (KPIs) and applies simulation tools to optimise energy consumption, thermal management and sustainability in the data centre environment. It addresses energy efficiency regulations and best practices in the sector.
The course provides practical knowledge of energy demand management, building management systems (BMS) and the integration of advanced cooling solutions, including liquid cooling and immersion cooling. It trains professionals in data centre engineering, energy management and sustainability, with the ability to optimise energy efficiency, reduce the carbon footprint and improve the profitability of data centres.
Take the controls.
Run a real engineering trade-off from this programme. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Analyse the energy consumption of a data centre using standardised indicators.
Design redundant electrical infrastructures according to availability levels.
Select air and liquid cooling technologies for high density.
Optimise operational efficiency with DCIM systems.
Integrate renewables, flexibility and waste heat reuse.
Comply with European energy reporting obligations for data centres.
Develop the energy design of a data centre.
Who it's for
- Data centre infrastructure engineer wishing to specialise in Energy Engineering in Data Centres.
- Data centre energy efficiency manager wishing to specialise in Energy Engineering in Data Centres.
- Cooling engineer wishing to specialise in Energy Engineering in Data Centres.
- Mission-critical electrical engineer wishing to specialise in Energy Engineering in Data Centres.
- Digital sustainability consultant wishing to specialise in Energy Engineering in Data Centres.
- Data centre operations manager wishing to specialise in Energy Engineering in Data Centres.
- Graduates in engineering or sciences seeking to enter data centres.
What you'll work with
- EN 50600
- ISO/IEC 30134-2
- ASHRAE TC 9.9 Thermal Guidelines
- ANSI/TIA-942
- Energy Efficiency Directive (EU) 2023/1791
- Delegated Regulation (EU) 2024/1364
- ISO 50001
- European Code of Conduct on Data Centre Energy Efficiency
6 modules · 300 h
1.1Demand components: IT, cooling and losses1.2PUE, WUE, CUE and ERF indicators1.3Power density per rack1.4Artificial intelligence and GPU loads1.5Tier availability classification1.6EN 50600 infrastructure standards1.7Load profiles and capacity growth1.8Location and climatic constraints1.9Global energy footprint of the sector1.10Workshop: calculating the PUE of a data centre
2.1High- and medium-voltage supply connection2.22N, N+1 and distributed topologies2.3Uninterruptible power supply systems2.4Generator sets and alternative fuels2.5Low-voltage distribution and PDUs2.6Lithium-ion batteries in UPS2.7DC distribution2.8Power quality and harmonics2.9Concurrent maintenance and redundancy2.10Laboratory: single-line diagram of a Tier III room
3.1ASHRAE TC 9.9 thermal guidelines3.2Cold and hot aisles and containment3.3Air cooling with CRAH and CRAC units3.4Direct and indirect free cooling3.5Direct-to-chip liquid cooling3.6Immersion cooling3.7High-efficiency chillers3.8CFD simulation of the room3.9Water consumption and cooling towers3.10Practical: CFD study of a high-density room
4.1DCIM infrastructure management4.2Real-time power monitoring4.3Optimisation of setpoints and flow rates4.4Virtualisation and IT load consolidation4.5European Data Centre Code of Conduct4.6Server efficiency measurement4.7Predictive maintenance of infrastructure4.8ISO 50001 energy management systems4.9Energy audits of data centres4.10Case study: PUE reduction plan
5.1Reuse of waste heat in district heating networks5.2Supply through renewable PPAs5.3On-site self-consumption and storage5.4Flexibility and demand response5.5Grid connection and available capacity5.6Reporting obligations under the Energy Efficiency Directive5.7EU taxonomy and data centres5.8Carbon footprint and Scope 2 emissions5.9Sustainability certifications5.10Case study: heat recovery for a district heating network
6.1Definition of IT capacity and availability6.2Electrical infrastructure design6.3Cooling system design6.4Annual PUE estimate6.5Renewable supply strategy6.6Use of waste heat6.7Economic analysis6.8Regulatory compliance plan6.9Report and presentation6.10Final review with the tutor
How you'll learn
Fully 100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: students progress at their own pace within the enrolment period, which makes it possible to combine the course with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is 6SigmaDCX, Schneider EcoStruxure IT, ETAP, EnergyPlus, Ansys Fluent, in free, academic or evaluation versions. Assignments are based on real procedures for calculating and improving a data centre's PUE, CFD simulation of a high-density room, and a study of waste heat reuse. Assessment is continuous by module, plus the final integrating project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Analyse the energy consumption of a data centre using standardised indicators.
Design redundant electrical infrastructures according to availability levels.
Select air and liquid cooling technologies for high density.
Optimise operational efficiency with DCIM systems.
Integrate renewables, flexibility and waste heat reuse.
Where this takes you
Requirements
- No prior degree is required.
- Internet connection and a computer capable of running the programme's software.
- Sufficient command of Spanish to follow technical regulatory texts.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme totals 300 hours, spread over 3 to 5 months. That is between 10 and 15 hours per week on average, compatible with full-time work.
You work with 6SigmaDCX, Schneider EcoStruxure IT, ETAP, EnergyPlus, Ansys Fluent. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.
An own diploma from SEIUM Institute upon passing continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the advanced programme. Check the recognition policy when you enrol.
Related programmes
Blockchain for Maritime Logistics Course
The Blockchain for Maritime Logistics Course explores how to implement blockchain technology to optimise and secure operations in the maritime industry. It covers the application of…
Classic Heavy-Vehicle Transmissions Course
Online 300-hour course in classic heavy-vehicle transmissions. 6 modules covering ISO 6336 (gear load capacity calculation), ISO 10825-1 (wear and damage on gear teeth) and KISSsoft.…
Course in Ethics in Dual Civil-Military Certification
Online 300-hour course in ethics in dual civil-military certification. 6 modules covering Regulation (EU) 2021/821 (dual-use products), Law 53/2007 (control of foreign trade in defence material…
More in Energy and Networks
All Energy and Networks programmes → · How to apply · Fees & financing · Scholarships