Energy Engineering in Data Centres Course

The Energy Engineering in Data Centres Course explores the design, optimisation and management of energy infrastructure in data centres. It focuses on energy efficiency, cooling, uninterruptible power supply systems (UPS), and the use of renewable energy to minimise environmental impact and reduce operating costs. It analyses key performance indicators (KPIs) and applies simulation tools to optimise energy consumption, thermal management and sustainability in the data centre environment. It addresses energy efficiency regulations and best practices in the sector.

The course provides practical knowledge of energy demand management, building management systems (BMS) and the integration of advanced cooling solutions, including liquid cooling and immersion cooling. It trains professionals in data centre engineering, energy management and sustainability, with the ability to optimise energy efficiency, reduce the carbon footprint and improve the profitability of data centres.

Duration300 h
ModeOnline
Start datesSet by the faculty
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this programme. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Analyse the energy consumption of a data centre using standardised indicators.

02

Design redundant electrical infrastructures according to availability levels.

03

Select air and liquid cooling technologies for high density.

04

Optimise operational efficiency with DCIM systems.

05

Integrate renewables, flexibility and waste heat reuse.

06

Comply with European energy reporting obligations for data centres.

07

Develop the energy design of a data centre.

Profile

Who it's for

  • Data centre infrastructure engineer wishing to specialise in Energy Engineering in Data Centres.
  • Data centre energy efficiency manager wishing to specialise in Energy Engineering in Data Centres.
  • Cooling engineer wishing to specialise in Energy Engineering in Data Centres.
  • Mission-critical electrical engineer wishing to specialise in Energy Engineering in Data Centres.
  • Digital sustainability consultant wishing to specialise in Energy Engineering in Data Centres.
  • Data centre operations manager wishing to specialise in Energy Engineering in Data Centres.
  • Graduates in engineering or sciences seeking to enter data centres.
Standards & tools

What you'll work with

  • EN 50600
  • ISO/IEC 30134-2
  • ASHRAE TC 9.9 Thermal Guidelines
  • ANSI/TIA-942
  • Energy Efficiency Directive (EU) 2023/1791
  • Delegated Regulation (EU) 2024/1364
  • ISO 50001
  • European Code of Conduct on Data Centre Energy Efficiency
Syllabus

6 modules · 300 h

  1. 1.1Demand components: IT, cooling and losses
  2. 1.2PUE, WUE, CUE and ERF indicators
  3. 1.3Power density per rack
  4. 1.4Artificial intelligence and GPU loads
  5. 1.5Tier availability classification
  6. 1.6EN 50600 infrastructure standards
  7. 1.7Load profiles and capacity growth
  8. 1.8Location and climatic constraints
  9. 1.9Global energy footprint of the sector
  10. 1.10Workshop: calculating the PUE of a data centre
  1. 2.1High- and medium-voltage supply connection
  2. 2.22N, N+1 and distributed topologies
  3. 2.3Uninterruptible power supply systems
  4. 2.4Generator sets and alternative fuels
  5. 2.5Low-voltage distribution and PDUs
  6. 2.6Lithium-ion batteries in UPS
  7. 2.7DC distribution
  8. 2.8Power quality and harmonics
  9. 2.9Concurrent maintenance and redundancy
  10. 2.10Laboratory: single-line diagram of a Tier III room
  1. 3.1ASHRAE TC 9.9 thermal guidelines
  2. 3.2Cold and hot aisles and containment
  3. 3.3Air cooling with CRAH and CRAC units
  4. 3.4Direct and indirect free cooling
  5. 3.5Direct-to-chip liquid cooling
  6. 3.6Immersion cooling
  7. 3.7High-efficiency chillers
  8. 3.8CFD simulation of the room
  9. 3.9Water consumption and cooling towers
  10. 3.10Practical: CFD study of a high-density room
  1. 4.1DCIM infrastructure management
  2. 4.2Real-time power monitoring
  3. 4.3Optimisation of setpoints and flow rates
  4. 4.4Virtualisation and IT load consolidation
  5. 4.5European Data Centre Code of Conduct
  6. 4.6Server efficiency measurement
  7. 4.7Predictive maintenance of infrastructure
  8. 4.8ISO 50001 energy management systems
  9. 4.9Energy audits of data centres
  10. 4.10Case study: PUE reduction plan
  1. 5.1Reuse of waste heat in district heating networks
  2. 5.2Supply through renewable PPAs
  3. 5.3On-site self-consumption and storage
  4. 5.4Flexibility and demand response
  5. 5.5Grid connection and available capacity
  6. 5.6Reporting obligations under the Energy Efficiency Directive
  7. 5.7EU taxonomy and data centres
  8. 5.8Carbon footprint and Scope 2 emissions
  9. 5.9Sustainability certifications
  10. 5.10Case study: heat recovery for a district heating network
  1. 6.1Definition of IT capacity and availability
  2. 6.2Electrical infrastructure design
  3. 6.3Cooling system design
  4. 6.4Annual PUE estimate
  5. 6.5Renewable supply strategy
  6. 6.6Use of waste heat
  7. 6.7Economic analysis
  8. 6.8Regulatory compliance plan
  9. 6.9Report and presentation
  10. 6.10Final review with the tutor
Methodology, software & labs

How you'll learn

Fully 100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: students progress at their own pace within the enrolment period, which makes it possible to combine the course with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is 6SigmaDCX, Schneider EcoStruxure IT, ETAP, EnergyPlus, Ansys Fluent, in free, academic or evaluation versions. Assignments are based on real procedures for calculating and improving a data centre's PUE, CFD simulation of a high-density room, and a study of waste heat reuse. Assessment is continuous by module, plus the final integrating project.

Accreditable laboratories(EN ISO/IEC 17025) with rotor test bench, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-oriented Master's Thesis:safety case, test plan, compliance dossier and operating limits.
Industry-mentored:lecturers with track records in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:safety-by-design approach, cyber-OT, DIH and compliance as pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Definition of IT capacity and availability

Analyse the energy consumption of a data centre using standardised indicators.

Electrical infrastructure design

Design redundant electrical infrastructures according to availability levels.

Cooling system design

Select air and liquid cooling technologies for high density.

Annual PUE estimate

Optimise operational efficiency with DCIM systems.

Renewable supply strategy

Integrate renewables, flexibility and waste heat reuse.

Career opportunities

Where this takes you

Data centre infrastructure engineerData centre energy efficiency managerCooling engineerMission-critical electrical engineerDigital sustainability consultantData centre operations manager
Admissions & scholarships

Requirements

  • No prior degree is required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient command of Spanish to follow technical regulatory texts.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme totals 300 hours, spread over 3 to 5 months. That is between 10 and 15 hours per week on average, compatible with full-time work.

You work with 6SigmaDCX, Schneider EcoStruxure IT, ETAP, EnergyPlus, Ansys Fluent. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

An own diploma from SEIUM Institute upon passing continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised in the advanced programme. Check the recognition policy when you enrol.

Energy Engineering in Data Centres CourseEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.