CourseMotorcycles & 2-Wheelers Enrolment open

Course in Redundancy Strategies for Urban Services

Online 300-hour course in Redundancy Strategies in Urban Services. 6 modules covering IEC 61078 Reliability block diagrams, IEC 61025 Fault tree analysis and ReliaSoft BlockSim. Assigned tutor and open enrolment.

Duration300 h
ModeOnline
Start datesOctober / March
LocationEurope (Madrid)
AwardSEIUM Institute diploma
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this programme. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Understand the concepts of redundancy, diversity and common cause failure.

02

Calculate the reliability and availability of redundant systems.

03

Analyse the connectivity of urban networks using graph theory.

04

Apply FMECA and fault trees to critical installations.

05

Optimise redundancy using cost-benefit criteria.

06

Plan tests that verify actual redundancy.

07

Propose redundancy improvements for an urban service.

Profile

Who it's for

  • Reliability engineer wishing to specialise in Redundancy Strategies in Urban Services.
  • Critical infrastructure manager wishing to specialise in Redundancy Strategies in Urban Services.
  • Technical continuity consultant wishing to specialise in Redundancy Strategies in Urban Services.
  • Data centre engineer wishing to specialise in Redundancy Strategies in Urban Services.
  • Facilities maintenance technician wishing to specialise in Redundancy Strategies in Urban Services.
  • Service network planner wishing to specialise in Redundancy Strategies in Urban Services.
  • Engineering or science graduates seeking to enter urban service operators.
Standards & tools

What you'll work with

  • IEC 61078 Reliability block diagrams
  • IEC 61025 Fault tree analysis
  • IEC 60812 Failure modes and effects analysis (FMEA and FMECA)
  • EN 50600 Data centre facilities and infrastructures
  • ISO 22301 Business continuity management systems
  • ANSI/TIA-942 Telecommunications infrastructure standard for data centres
  • IEC 60300-3-1 Dependability management: analysis techniques
Syllabus

6 modules · 300 h

  1. 1.1Redundancy, diversity and separation
  2. 1.2Active, passive and standby redundancy
  3. 1.3N, N+1, 2N and 2N+1 configurations
  4. 1.4Common and dependent failure modes
  5. 1.5Reliability of series and parallel systems
  6. 1.6Availability and mean time between failures
  7. 1.7Reliability block diagrams
  8. 1.8Fault trees and minimal cut set analysis
  9. 1.9Cost of redundancy versus risk
  10. 1.10Practice: availability calculation for an N+1 configuration
  1. 2.1Meshed versus branched topologies
  2. 2.2Graph theory and connectivity
  3. 2.3Dual supply in electricity networks
  4. 2.4Water distribution rings
  5. 2.5Alternative routes in road networks
  6. 2.6Route diversity in optical fibre
  7. 2.7Interconnection between neighbouring operators
  8. 2.8Geographic redundancy of control centres
  9. 2.9Analysis of critical nodes and edges
  10. 2.10Laboratory: connectivity analysis of a network with NetworkX
  1. 3.1Tier classification of data centres
  2. 3.2Electrical systems with dual incoming supply
  3. 3.3Redundant air conditioning in technical rooms
  4. 3.4Pumping with standby equipment
  5. 3.5Storage of fuel and reagents
  6. 3.6Emergency communications: TETRA and satellite
  7. 3.7Backup processing centres
  8. 3.8Concurrent maintenance without loss of service
  9. 3.9Automatic changeover testing
  10. 3.10Case study: redundancy audit of a municipal data centre
  1. 4.1Design criteria according to criticality
  2. 4.2FMECA analysis of urban systems
  3. 4.3Optimisation of redundancy allocation
  4. 4.4Cost-benefit analysis and the value of availability
  5. 4.5Redundancy versus robustness and flexibility
  6. 4.6Monte Carlo simulation models
  7. 4.7Modular and scalable design
  8. 4.8Organisational and staffing redundancy
  9. 4.9Alternative suppliers in the supply chain
  10. 4.10Workshop: FMECA of a stormwater pumping station
  1. 5.1Inventory of existing redundancies
  2. 5.2Risks of untested latent redundancy
  3. 5.3Testing and maintenance programmes
  4. 5.4Availability and reliability indicators
  5. 5.5Change and configuration management
  6. 5.6Lessons from failures with compromised redundancy
  7. 5.7Contracting redundancy in concessions
  8. 5.8Integration into continuity plans
  9. 5.9Independent redundancy audit
  10. 5.10Case study: simultaneous failure of main and backup power supply
  1. 6.1Selection of the service under study
  2. 6.2Functional and reliability model
  3. 6.3Identification of single points of failure
  4. 6.4Proposed redundancy alternatives
  5. 6.5Calculation of resulting availability
  6. 6.6Cost-benefit analysis of the alternatives
  7. 6.7Testing and maintenance plan
  8. 6.8Integration into service continuity
  9. 6.9Report and presentation
  10. 6.10Final review with the tutor
Methodology, software & labs

How you'll learn

Fully 100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: students progress at their own pace within the intake, which makes it possible to combine the programme with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is ReliaSoft BlockSim, NetworkX, Isograph Reliability Workbench, MATLAB, EPANET, in free, academic or evaluation versions. Tests are studied using real availability calculation procedures for redundant configurations, FMECA analysis of a pumping installation, and identification of single points of failure in an urban network. Assessment is continuous per module plus the final integrating project.

Accreditable laboratories(EN ISO/IEC 17025) with rotor test rig, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-oriented Master's Thesis:safety case, test plan, compliance dossier and operational limits.
Industry mentoring:lecturers with track records in la formacion, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:safety-by-design approach, cyber-OT, DIH and compliance as core pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Selection of the service under study

Understand the concepts of redundancy, diversity and common cause failure.

Functional and reliability model

Calculate the reliability and availability of redundant systems.

Identification of single points of failure

Analyse the connectivity of urban networks using graph theory.

Proposed redundancy alternatives

Apply FMECA and fault trees to critical installations.

Calculation of resulting availability

Optimise redundancy using cost-benefit criteria.

Career opportunities

Where this takes you

Reliability engineerCritical infrastructure managerTechnical continuity consultantData centre engineerFacilities maintenance technicianService network planner
Admissions & scholarships

Requirements

  • No prior qualification required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient Spanish to follow technical standards documentation.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme comprises 300 hours in total, spread over 3 to 5 months. That is between 10 and 15 hours per week on average, compatible with a full-time job.

You work with ReliaSoft BlockSim, NetworkX, Isograph Reliability Workbench, MATLAB, EPANET. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

An SEIUM own diploma upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or postgraduate diploma in the same area are recognised towards the higher programme. Please check the recognition policy when you enrol.

Course in Redundancy Strategies for Urban ServicesEnrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.