Course in Redundancy Strategies for Urban Services
Online 300-hour course in Redundancy Strategies in Urban Services. 6 modules covering IEC 61078 Reliability block diagrams, IEC 61025 Fault tree analysis and ReliaSoft BlockSim. Assigned tutor and open enrolment.
Take the controls.
Run a real engineering trade-off from this programme. Move the sliders, watch the model react in real time and beat the challenge.
What you will be able to do
Understand the concepts of redundancy, diversity and common cause failure.
Calculate the reliability and availability of redundant systems.
Analyse the connectivity of urban networks using graph theory.
Apply FMECA and fault trees to critical installations.
Optimise redundancy using cost-benefit criteria.
Plan tests that verify actual redundancy.
Propose redundancy improvements for an urban service.
Who it's for
- Reliability engineer wishing to specialise in Redundancy Strategies in Urban Services.
- Critical infrastructure manager wishing to specialise in Redundancy Strategies in Urban Services.
- Technical continuity consultant wishing to specialise in Redundancy Strategies in Urban Services.
- Data centre engineer wishing to specialise in Redundancy Strategies in Urban Services.
- Facilities maintenance technician wishing to specialise in Redundancy Strategies in Urban Services.
- Service network planner wishing to specialise in Redundancy Strategies in Urban Services.
- Engineering or science graduates seeking to enter urban service operators.
What you'll work with
- IEC 61078 Reliability block diagrams
- IEC 61025 Fault tree analysis
- IEC 60812 Failure modes and effects analysis (FMEA and FMECA)
- EN 50600 Data centre facilities and infrastructures
- ISO 22301 Business continuity management systems
- ANSI/TIA-942 Telecommunications infrastructure standard for data centres
- IEC 60300-3-1 Dependability management: analysis techniques
6 modules · 300 h
1.1Redundancy, diversity and separation1.2Active, passive and standby redundancy1.3N, N+1, 2N and 2N+1 configurations1.4Common and dependent failure modes1.5Reliability of series and parallel systems1.6Availability and mean time between failures1.7Reliability block diagrams1.8Fault trees and minimal cut set analysis1.9Cost of redundancy versus risk1.10Practice: availability calculation for an N+1 configuration
2.1Meshed versus branched topologies2.2Graph theory and connectivity2.3Dual supply in electricity networks2.4Water distribution rings2.5Alternative routes in road networks2.6Route diversity in optical fibre2.7Interconnection between neighbouring operators2.8Geographic redundancy of control centres2.9Analysis of critical nodes and edges2.10Laboratory: connectivity analysis of a network with NetworkX
3.1Tier classification of data centres3.2Electrical systems with dual incoming supply3.3Redundant air conditioning in technical rooms3.4Pumping with standby equipment3.5Storage of fuel and reagents3.6Emergency communications: TETRA and satellite3.7Backup processing centres3.8Concurrent maintenance without loss of service3.9Automatic changeover testing3.10Case study: redundancy audit of a municipal data centre
4.1Design criteria according to criticality4.2FMECA analysis of urban systems4.3Optimisation of redundancy allocation4.4Cost-benefit analysis and the value of availability4.5Redundancy versus robustness and flexibility4.6Monte Carlo simulation models4.7Modular and scalable design4.8Organisational and staffing redundancy4.9Alternative suppliers in the supply chain4.10Workshop: FMECA of a stormwater pumping station
5.1Inventory of existing redundancies5.2Risks of untested latent redundancy5.3Testing and maintenance programmes5.4Availability and reliability indicators5.5Change and configuration management5.6Lessons from failures with compromised redundancy5.7Contracting redundancy in concessions5.8Integration into continuity plans5.9Independent redundancy audit5.10Case study: simultaneous failure of main and backup power supply
6.1Selection of the service under study6.2Functional and reliability model6.3Identification of single points of failure6.4Proposed redundancy alternatives6.5Calculation of resulting availability6.6Cost-benefit analysis of the alternatives6.7Testing and maintenance plan6.8Integration into service continuity6.9Report and presentation6.10Final review with the tutor
How you'll learn
Fully 100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. No fixed timetables: students progress at their own pace within the intake, which makes it possible to combine the programme with work.
Each module combines theory, guided reading of the original standard and applied exercises. The working software is ReliaSoft BlockSim, NetworkX, Isograph Reliability Workbench, MATLAB, EPANET, in free, academic or evaluation versions. Tests are studied using real availability calculation procedures for redundant configurations, FMECA analysis of a pumping installation, and identification of single points of failure in an urban network. Assessment is continuous per module plus the final integrating project.
Build it end to end
Your final project follows the real engineering workflow, step by step, reviewed by your tutor.
Understand the concepts of redundancy, diversity and common cause failure.
Calculate the reliability and availability of redundant systems.
Analyse the connectivity of urban networks using graph theory.
Apply FMECA and fault trees to critical installations.
Optimise redundancy using cost-benefit criteria.
Where this takes you
Requirements
- No prior qualification required.
- Internet connection and a computer capable of running the programme's software.
- Sufficient Spanish to follow technical standards documentation.
Ready to start?
Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.
Frequently asked questions
The programme comprises 300 hours in total, spread over 3 to 5 months. That is between 10 and 15 hours per week on average, compatible with a full-time job.
You work with ReliaSoft BlockSim, NetworkX, Isograph Reliability Workbench, MATLAB, EPANET. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.
An SEIUM own diploma upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.
Yes. Modules passed in a course or postgraduate diploma in the same area are recognised towards the higher programme. Please check the recognition policy when you enrol.
Related programmes
Entrepreneurship course in the electric motorcycle sector
The Entrepreneurship Course in the Electric Motorcycle Sector explores business opportunities in sustainable mobility, from design to commercialization. It focuses on analyzing the electric two-wheeler market,…
Tractor Consumption Testing Course
300-hour online course in tractor consumption testing. 6 modules with OECD Code 2 (official tractor performance test), ISO 789-1 (power take-off power test) and NI LabVIEW.…
Data Privacy and Ethics in Telematics Insurance Course
Online 300 h course in data privacy and ethics in telematics insurance. 6 modules covering Regulation (EU) 2016/679 (GDPR), Organic Law 3/2018 (LOPDGDD) and OneTrust. Assigned…
More in Motorcycles & 2-Wheelers
All Motorcycles & 2-Wheelers programmes → · How to apply · Fees & financing · Scholarships