CourseEnergy and Networks Applications open

Course in ISO Standards and Safety in H₂

Online 300-hour course in ISO standards and H₂ safety. 6 modules covering ISO/TR 15916, ISO 22734 and HyRAM+. Assigned tutor and open enrolment.

Duration300 h
ModeOnline
Start datesSet by the faculty
AwardSEIUM Institute certificate
Virtual lab · try it before you enrol

Take the controls.

Run a real engineering trade-off from this field. Move the sliders, watch the model react in real time and beat the challenge.

SIM · LIVE ●
Learning outcomes

What you will be able to do

01

Identify the specific hazards of gaseous and liquid hydrogen.

02

Apply the ISO standards of technical committee TC 197 to real installations.

03

Classify areas with explosive atmospheres and select suitable equipment.

04

Carry out HAZOP, LOPA and quantitative risk analyses.

05

Model the consequences of leaks, fires and explosions.

06

Interpret the European and national legal framework for industrial safety.

07

Prepare the complete safety study of a hydrogen installation.

Profile

Who it's for

  • Industrial safety technician wishing to specialise in ISO Standards and Safety in H₂.
  • Process safety engineer wishing to specialise in ISO Standards and Safety in H₂.
  • ATEX consultant wishing to specialise in ISO Standards and Safety in H₂.
  • Prevention manager at hydrogen plants wishing to specialise in ISO Standards and Safety in H₂.
  • Technical standards auditor wishing to specialise in ISO Standards and Safety in H₂.
  • Functional safety engineer wishing to specialise in ISO Standards and Safety in H₂.
  • Engineering or science graduates looking to enter the hydrogen and industrial gases sector.
Standards & tools

What you'll work with

  • ISO/TR 15916
  • ISO 22734
  • ISO 19880-1
  • Directiva 2014/34/UE (ATEX)
  • Directiva 1999/92/CE
  • IEC 60079-10-1
  • IEC 61511
  • Directiva 2012/18/UE (Seveso III)
Syllabus

6 modules · 300 h

  1. 1.1Physical properties relevant to safety
  2. 1.2Flammability and detonability range
  3. 1.3Invisible flames and thermal radiation
  4. 1.4Leaks, buoyancy and dispersion
  5. 1.5Deflagration and transition to detonation
  6. 1.6Liquid hydrogen and cryogenic risks
  7. 1.7Asphyxiation and effects on people
  8. 1.8Embrittlement and material failures
  9. 1.9Comparison of hazards with other fuels
  10. 1.10Workshop: analysis of an indoor leak scenario
  1. 2.1Structure and work of ISO/TC 197
  2. 2.2ISO/TR 15916 basic safety considerations
  3. 2.3ISO 22734 electrolysis generators
  4. 2.4ISO 19880 service stations
  5. 2.5ISO 14687 hydrogen quality
  6. 2.6ISO 16111 metal hydride devices
  7. 2.7ISO 19884 stationary storage vessels
  8. 2.8IEC 62282 standards for fuel cells
  9. 2.9Relationship with national EN and UNE standards
  10. 2.10Practice: standards matrix for an electrolysis plant
  1. 3.1ATEX Directive 2014/34/EU on equipment
  2. 3.2Directive 1999/92/EC on workplaces
  3. 3.3Zone classification according to IEC 60079-10-1
  4. 3.4Ventilation and dilution of leaks
  5. 3.5Hydrogen and flame detection
  6. 3.6Selection of flameproof electrical equipment
  7. 3.7Vents, stacks and pressure relief
  8. 3.8Safety distances and separation
  9. 3.9Explosion protection document
  10. 3.10Laboratory: zone classification in an electrolysis container
  1. 4.1HAZID and HAZOP methodology
  2. 4.2LOPA analysis and SIL levels
  3. 4.3Functional safety according to IEC 61511
  4. 4.4Quantitative risk analysis
  5. 4.5Consequence modelling of jets and explosions
  6. 4.6Fault trees and event trees
  7. 4.7HIAD incident databases
  8. 4.8Risk tolerability criteria
  9. 4.9Safety barriers and bow-tie
  10. 4.10Case study: HAZOP of a PEM electrolyser
  1. 5.1Seveso III Directive and hydrogen thresholds
  2. 5.2Regulation on storage of chemical products
  3. 5.3Pressure equipment regulation
  4. 5.4Installation permits and authorisations
  5. 5.5Process safety management system
  6. 5.6Internal and external emergency plan
  7. 5.7Staff training and competences
  8. 5.8Inspections, audits and continuous improvement
  9. 5.9Safety culture and human factors
  10. 5.10Case study: emergency plan for a hydrogen refuelling station
  1. 6.1Description of the installation under study
  2. 6.2Hazard identification
  3. 6.3ATEX zone classification
  4. 6.4HAZOP and LOPA analysis
  5. 6.5Consequence modelling
  6. 6.6Prevention and mitigation measures
  7. 6.7Documented regulatory compliance
  8. 6.8Emergency plan and training
  9. 6.9Report and presentation
  10. 6.10Final review with the tutor
Methodology, software & labs

How you'll learn

Fully 100% online training on the SEIUM campus, with downloadable material, recorded classes and an assigned technical tutor. There are no fixed timetables: students progress at their own pace within the intake, which makes it possible to combine the course with work.

Each module combines theory, guided reading of the original standard and applied exercises. The working software is HyRAM+, DNV PHAST, FLACS-CFD, PHA-Pro, ALOHA, in free, academic or evaluation versions. Practical work is based on real ATEX zone classification procedures for an electrolysis plant, a HAZOP of a refuelling station, and consequence modelling of an ignited hydrogen jet. Assessment is continuous across each module, plus the final integrating project.

Accredited laboratories(EN ISO/IEC 17025) with rotor bench, EMC/Lightning pre-compliance, HIL/SIL, vibration/acoustics.
Evidence-oriented Master's Thesis:safety case, test plan, compliance dossier and operating limits.
Industry mentoring:lecturers with experience in training, , eVTOL/UAM and flight test.
Flexible format(hybrid/online), international cohorts and support from SEIUM Career Services.
Ethics and safety:a safety-by-design approach, with ciber-OT, DIH and compliance as its pillars.
Capstone project

Build it end to end

Your final project follows the real engineering workflow, step by step, reviewed by your tutor.

Description of the installation under study

Identify the specific hazards of gaseous and liquid hydrogen.

Hazard identification

Apply the ISO standards of technical committee TC 197 to real installations.

ATEX zone classification

Classify areas with explosive atmospheres and select suitable equipment.

HAZOP and LOPA analysis

Carry out HAZOP, LOPA and quantitative risk analyses.

Consequence modelling

Model the consequences of leaks, fires and explosions.

Career opportunities

Where this takes you

Industrial safety technicianProcess safety engineerATEX consultantPrevention manager at hydrogen plantsTechnical standards auditorFunctional safety engineer
Admissions & scholarships

Requirements

  • No prior degree required.
  • Internet connection and a computer capable of running the programme's software.
  • Sufficient level of Spanish to follow technical standards texts.

Ready to start?

Send your application today. Our admissions team replies within 72 hours with your study plan and funding options.

FAQ

Frequently asked questions

The programme consists of 300 hours in total, spread over 3 to 5 months. That is an average of 10 to 15 hours per week, compatible with a full-time job.

You will work with HyRAM+, DNV PHAST, FLACS-CFD, PHA-Pro and ALOHA. Free, academic or evaluation versions are used, and the tutor indicates the free alternative where one exists.

SEIUM's own diploma upon passing the continuous assessment and the integrating project. It is in-house training, not an official qualification from the Ministry.

Yes. Modules passed in a course or Postgraduate Diploma in the same area count towards the higher programme. Check the recognition policy when you enrol.

Course in ISO Standards and Safety in H₂Enrol
Scroll to Top
SEIUM – Institute of Advanced Engineering
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.